"Pr\u016Ftokov\u00FD m\u011B\u0159i\u010D vzduchu pro vdech i v\u00FDdech z\u00E1rove\u0148" . "http://biomech.ftvs.cuni.cz/kab/veda/VaV.php" . . . . "RIV/00216208:11510/12:10125485!RIV13-MSM-11510___" . . . "Pr\u016Ftokov\u00FD m\u011B\u0159i\u010D vzduchu pro vdech i v\u00FDdech z\u00E1rove\u0148" . "Pr\u016Ftokov\u00E9 m\u011B\u0159i\u010De jsou dnes pr\u016Fmyslov\u011B vyr\u00E1b\u011Bny, co\u017E se odr\u00E1\u017E\u00ED ve faktu, \u017Ee m\u011B\u0159i\u010De m\u011B\u0159\u00ED samotn\u00FD objem prot\u00E9kaj\u00EDc\u00EDho vzduchu bez informace, kter\u00FDm sm\u011Brem tok vede. N\u011Bkter\u00E9 spirometry sice zji\u0161\u0165uj\u00ED hodnotu n\u00E1dechu i v\u00FDdechu, toto zji\u0161t\u011Bn\u00ED ale poch\u00E1z\u00ED na z\u00E1klad\u011B naprogramov\u00E1n\u00ED softwaru, kter\u00FD p\u0159edpokl\u00E1d\u00E1, \u017Ee spirometrick\u00FD test je slo\u017Een pr\u00E1v\u011B z hlubok\u00FDch n\u00E1dech\u016F a v\u00FDdech\u016F. U dal\u0161\u00EDch spirometr\u016F je zase obousm\u011Brn\u00FD pr\u016Ftokom\u011Br zabudov\u00E1n pevn\u011B do soustavy analyz\u00E1tor\u016F O2 nebo CO2 a v\u00FDstup ze spirometru je mo\u017En\u00FD jen z origin\u00E1ln\u00EDho softwaru. Sou\u010Dasn\u00E1 t\u00E9mata \u0159e\u0161\u00EDc\u00ED zm\u011Bny dechu u konkr\u00E9tn\u00EDch cvi\u010Den\u00EDch v\u0161ak vy\u017Eaduj\u00ED velmi p\u0159esn\u00E9 a p\u0159\u00EDm\u00E9 zji\u0161\u0165\u011Bn\u00ED objemu vzduchu p\u0159i n\u00E1dechu a v\u00FDdechu. Funk\u010Dn\u00ED vzorek \u0159e\u0161\u00ED problematiku obousm\u011Brn\u00E9ho pr\u016Ftokov\u00E9ho m\u011B\u0159i\u010De, kter\u00FD je mo\u017En\u00E9 instalovat do jak\u00E9koliv pr\u016Ftokov\u00E9 soustavy samostatn\u011B. Nav\u00EDc je \u0159e\u0161en pomoc\u00ED laserov\u00E9 diody a fotodiody, co\u017E nem\u011Bn\u00ED vlastnosti pr\u016Ftokov\u00E9 soustavy. Nav\u00EDc lze tento m\u011B\u0159i\u010D samostatn\u011B instalovat do jak\u00E9koliv respira\u010Dn\u00ED pr\u016Ftokov\u00E9 soustav nap\u0159. v pr\u00E1ci: Pou\u017Eito nap\u0159v: DOLANSK\u00C1, Tereza. Vliv opakovan\u011B prov\u00E1d\u011Bn\u00FDch dechov\u00FDch cvi\u010Den\u00ED na tvar trupu a pohyblivost p\u00E1te\u0159e. Praha, 2008. 83 s. Vedouc\u00ED pr\u00E1ce Franti\u0161ek V\u00E9le."@cs . . . "3"^^ . . "3"^^ . "[CCE6289D5032]" . . "Pr\u016Ftokov\u00FD m\u011B\u0159i\u010D vzduchu pro vdech i v\u00FDdech z\u00E1rove\u0148"@cs . . . "Licen\u010Dn\u00ED smouva s p\u016Fvodci podepsan\u00E1 dne 14.11.2012" . "163360" . . . . . . "Jelen, Karel" . . "exhalation, spirometry; inhalation; flow meter"@en . . "Pr\u016Ftokov\u00FD m\u011B\u0159i\u010D vzduchu pro vdech i v\u00FDdech z\u00E1rove\u0148"@cs . . "Dolansk\u00E1, Tereza" . "RIV/00216208:11510/12:10125485" . "The flow meters are manufactured industrially, which is reflected in the fact that the meter measured the air volume itself without the information, in which direction the flow leads. Some may find the value of spirometry, but this finding is based on the programming software, which assumes by producer. For other flow analysis it is again two-way flow meter already in system analysers O2 or CO2. The output from spirometry is possible only from the original software. For specific breathing exercises is require a very precise and direct findings.The functional sample addresses the issue of two-way control meter, which can be installed into any spirometry system separately. Moreover, it is addressed using a laser diode and a photodiode, which does not change the properties of the measurement. In addition, you can install separately to meter any respiratory flow systems, e.g. in the DOLANSK\u00C1, Tereza. Vliv opakovan\u011B prov\u00E1d\u011Bn\u00FDch dechov\u00FDch cvi\u010Den\u00ED na tvar trupu a pohyblivost p\u00E1te\u0159e. Praha, 2008. 83 s. Vedouc\u00ED pr\u00E1ce Franti\u0161ek V\u00E9le"@en . "11510" . "The flow meter for both - inhalation and exhalation"@en . "The flow meter for both - inhalation and exhalation"@en . "N\u00E1klady: Vytvo\u0159en\u00ED funk\u010Dn\u00EDho vzorku m\u011Blo n\u00E1kladovou cenu 20 000 CZK, Laborato\u0159 nemus\u00ED nakupovat dra\u017E\u0161\u00ED obdobn\u00E9 soustavy jednotliv\u011B v \u0159\u00E1dov\u011B stejn\u00FDch \u010D\u00E1stk\u00E1ch a funk\u010Dn\u00ED vzorek je aplikovateln\u00FD na dal\u0161\u00ED spirometrick\u00E9 sestavy." . . "Kubov\u00FD, Petr" . "KAB/2012/FV2" . . . . "P(GAP407/10/1624), S" . "Pr\u016Ftokov\u00E9 m\u011B\u0159i\u010De jsou dnes pr\u016Fmyslov\u011B vyr\u00E1b\u011Bny, co\u017E se odr\u00E1\u017E\u00ED ve faktu, \u017Ee m\u011B\u0159i\u010De m\u011B\u0159\u00ED samotn\u00FD objem prot\u00E9kaj\u00EDc\u00EDho vzduchu bez informace, kter\u00FDm sm\u011Brem tok vede. N\u011Bkter\u00E9 spirometry sice zji\u0161\u0165uj\u00ED hodnotu n\u00E1dechu i v\u00FDdechu, toto zji\u0161t\u011Bn\u00ED ale poch\u00E1z\u00ED na z\u00E1klad\u011B naprogramov\u00E1n\u00ED softwaru, kter\u00FD p\u0159edpokl\u00E1d\u00E1, \u017Ee spirometrick\u00FD test je slo\u017Een pr\u00E1v\u011B z hlubok\u00FDch n\u00E1dech\u016F a v\u00FDdech\u016F. U dal\u0161\u00EDch spirometr\u016F je zase obousm\u011Brn\u00FD pr\u016Ftokom\u011Br zabudov\u00E1n pevn\u011B do soustavy analyz\u00E1tor\u016F O2 nebo CO2 a v\u00FDstup ze spirometru je mo\u017En\u00FD jen z origin\u00E1ln\u00EDho softwaru. Sou\u010Dasn\u00E1 t\u00E9mata \u0159e\u0161\u00EDc\u00ED zm\u011Bny dechu u konkr\u00E9tn\u00EDch cvi\u010Den\u00EDch v\u0161ak vy\u017Eaduj\u00ED velmi p\u0159esn\u00E9 a p\u0159\u00EDm\u00E9 zji\u0161\u0165\u011Bn\u00ED objemu vzduchu p\u0159i n\u00E1dechu a v\u00FDdechu. Funk\u010Dn\u00ED vzorek \u0159e\u0161\u00ED problematiku obousm\u011Brn\u00E9ho pr\u016Ftokov\u00E9ho m\u011B\u0159i\u010De, kter\u00FD je mo\u017En\u00E9 instalovat do jak\u00E9koliv pr\u016Ftokov\u00E9 soustavy samostatn\u011B. Nav\u00EDc je \u0159e\u0161en pomoc\u00ED laserov\u00E9 diody a fotodiody, co\u017E nem\u011Bn\u00ED vlastnosti pr\u016Ftokov\u00E9 soustavy. Nav\u00EDc lze tento m\u011B\u0159i\u010D samostatn\u011B instalovat do jak\u00E9koliv respira\u010Dn\u00ED pr\u016Ftokov\u00E9 soustav nap\u0159. v pr\u00E1ci: Pou\u017Eito nap\u0159v: DOLANSK\u00C1, Tereza. Vliv opakovan\u011B prov\u00E1d\u011Bn\u00FDch dechov\u00FDch cvi\u010Den\u00ED na tvar trupu a pohyblivost p\u00E1te\u0159e. Praha, 2008. 83 s. Vedouc\u00ED pr\u00E1ce Franti\u0161ek V\u00E9le." .