"Elektrochemick\u00E1 detekce s elektrodami mimo roztok : znovuzrozen\u00ED bezkontaktn\u00EDch impedan\u010Dn\u00EDch metod."@cs . "\u0160tul\u00EDk, Karel" . . . . "P(GAP206/10/1231), Z(MSM0021620857)" . "Publikace kriticky hodnot\u00ED v\u00FDsledky z\u00EDskan\u00E9 p\u0159i studiu teorie vysokofrekven\u010Dn\u00EDch impedan\u010Dn\u00EDch detektor\u016F (dnes v\u011Bt\u0161inou zvan\u00FDch kapacitn\u011B v\u00E1zan\u00E9 bezkontaktn\u00ED vodivostn\u00ED detektory), z\u00E1kladn\u00ED p\u0159\u00EDstupy k n\u00E1vrh\u016Fm impedan\u010Dn\u00EDch pr\u016Ftokov\u00FDch cel a jejich opera\u010Dn\u00ED parametry, z\u00EDskan\u00E9 na Kated\u0159e analytick\u00E9 chemie Karlovy Univerzity v Praze, a diskutuje je v kontextu s celosv\u011Btov\u00FDm v\u00FDzkumem v t\u00E9to oblasti. Jsou uv\u00E1d\u011Bny p\u0159\u00EDklady n\u00E1vrh\u016F detek\u010Dn\u00EDch cel pro kontinu\u00E1ln\u00ED pr\u016Ftokovou a pr\u016Ftokovou injek\u010Dn\u00ED anal\u00FDzu a pro detekci v kapalinov\u00E9 chromatografii a kapil\u00E1rn\u00ED elektrofor\u00E9ze. Rovn\u011B\u017E jsou presentov\u00E1ny detek\u010Dn\u00ED cely pro vs\u00E1dkovou anal\u00FDzu a diskutov\u00E1ny jejich pracovn\u00ED parametry." . . "0009-2770" . . . "CZ - \u010Cesk\u00E1 republika" . "2"^^ . "Methods.; Impedance; Contactless; Rebirth; The; Solution; Test; the; Outside; Electrodes; with; Detection; Electrochemical"@en . "Chemick\u00E9 listy" . "Publikace kriticky hodnot\u00ED v\u00FDsledky z\u00EDskan\u00E9 p\u0159i studiu teorie vysokofrekven\u010Dn\u00EDch impedan\u010Dn\u00EDch detektor\u016F (dnes v\u011Bt\u0161inou zvan\u00FDch kapacitn\u011B v\u00E1zan\u00E9 bezkontaktn\u00ED vodivostn\u00ED detektory), z\u00E1kladn\u00ED p\u0159\u00EDstupy k n\u00E1vrh\u016Fm impedan\u010Dn\u00EDch pr\u016Ftokov\u00FDch cel a jejich opera\u010Dn\u00ED parametry, z\u00EDskan\u00E9 na Kated\u0159e analytick\u00E9 chemie Karlovy Univerzity v Praze, a diskutuje je v kontextu s celosv\u011Btov\u00FDm v\u00FDzkumem v t\u00E9to oblasti. Jsou uv\u00E1d\u011Bny p\u0159\u00EDklady n\u00E1vrh\u016F detek\u010Dn\u00EDch cel pro kontinu\u00E1ln\u00ED pr\u016Ftokovou a pr\u016Ftokovou injek\u010Dn\u00ED anal\u00FDzu a pro detekci v kapalinov\u00E9 chromatografii a kapil\u00E1rn\u00ED elektrofor\u00E9ze. Rovn\u011B\u017E jsou presentov\u00E1ny detek\u010Dn\u00ED cely pro vs\u00E1dkovou anal\u00FDzu a diskutov\u00E1ny jejich pracovn\u00ED parametry."@cs . . . "11310" . . . "Electrochemical Detection with Electrodes Outside the Test Solution : The Rebirth of Contactless Impedance Methods."@en . . "Elektrochemick\u00E1 detekce s elektrodami mimo roztok : znovuzrozen\u00ED bezkontaktn\u00EDch impedan\u010Dn\u00EDch metod."@cs . "Elektrochemick\u00E1 detekce s elektrodami mimo roztok : znovuzrozen\u00ED bezkontaktn\u00EDch impedan\u010Dn\u00EDch metod." . "256824" . . "7"^^ . "2"^^ . "The paper critically discusses the results obtained in the studies of the theory of high-frequency impedance sensors (now mostly called capacitively-coupled contactless conductivity sensors), the principal approaches to designing impedance flow-through cells and their operational parameters, obtained at the Charles University in Prague, Department of Analytical Chemistry, and places them into the world research context. Examples are given of cell designs for continuous flow and flow-injection analyses, and of detection systems for liquid chromatography and capillary electrophoresis. Cells for batch analyses are also presented and their operational parameters discussed."@en . . "12" . . . . . "RIV/00216208:11310/10:10057070" . . . . . . "Opekar, Franti\u0161ek" . "104" . "[34EF3BFC9E21]" . . . "Elektrochemick\u00E1 detekce s elektrodami mimo roztok : znovuzrozen\u00ED bezkontaktn\u00EDch impedan\u010Dn\u00EDch metod." . . . "RIV/00216208:11310/10:10057070!RIV11-GA0-11310___" . . . "Electrochemical Detection with Electrodes Outside the Test Solution : The Rebirth of Contactless Impedance Methods."@en .