"P\u0159\u00EDstroj pro in-vivo chlazen\u00ED krve v\u011Bt\u0161\u00EDch laboratorn\u00EDch zv\u00ED\u0159at"@cs . . "Petr\u00E1nkov\u00E1, Zuzana" . . "P\u0159\u00EDstroj pro in-vivo chlazen\u00ED krve v\u011Bt\u0161\u00EDch laboratorn\u00EDch zv\u00ED\u0159at"@cs . . "PBCCU 01" . "R\u016F\u017Ei\u010Dka, Ji\u0159\u00ED" . . "3"^^ . "3"^^ . "[86C97C1F31D0]" . "11140" . . . "P\u0159\u00EDstroj byl vyvinut pro experimenty na zv\u00ED\u0159atech jako alternativa k p\u0159\u00EDstroji, kter\u00FD se pou\u017E\u00EDv\u00E1 v hum\u00E1nn\u00ED medic\u00EDn\u011B, kter\u00FD je v\u0161ak v\u00FDznamn\u011B komplikovan\u011Bj\u0161\u00ED a dra\u017E\u0161\u00ED. Hlavn\u00ED funkc\u00ED p\u0159\u00EDstroje je zvy\u0161ov\u00E1n\u00ED tlaku a t\u00EDm i pr\u016Ftoku chlad\u00EDc\u00ED kapaliny chlad\u00EDc\u00EDm katetrem. Vedlej\u0161\u00ED funkc\u00ED p\u0159\u00EDstroje je m\u011B\u0159en\u00ED tlaku, pr\u016Ftoku a teploty chlad\u00EDc\u00ED kapaliny alarm pro p\u0159\u00EDpad nebezpe\u010Dn\u00E9ho poklesu pr\u016Ftoku chlad\u00EDc\u00ED kapaliny." . "282025" . . "Bolek, Luk\u00E1\u0161" . "P\u0159\u00EDstroj pro in-vivo chlazen\u00ED krve v\u011Bt\u0161\u00EDch laboratorn\u00EDch zv\u00ED\u0159at" . "RIV/00216208:11140/10:00300412!RIV11-MSM-11140___" . . "P\u0159\u00EDstroj byl vyvinut pro experimenty na zv\u00ED\u0159atech jako alternativa k p\u0159\u00EDstroji, kter\u00FD se pou\u017E\u00EDv\u00E1 v hum\u00E1nn\u00ED medic\u00EDn\u011B, kter\u00FD je v\u0161ak v\u00FDznamn\u011B komplikovan\u011Bj\u0161\u00ED a dra\u017E\u0161\u00ED. Hlavn\u00ED funkc\u00ED p\u0159\u00EDstroje je zvy\u0161ov\u00E1n\u00ED tlaku a t\u00EDm i pr\u016Ftoku chlad\u00EDc\u00ED kapaliny chlad\u00EDc\u00EDm katetrem. Vedlej\u0161\u00ED funkc\u00ED p\u0159\u00EDstroje je m\u011B\u0159en\u00ED tlaku, pr\u016Ftoku a teploty chlad\u00EDc\u00ED kapaliny alarm pro p\u0159\u00EDpad nebezpe\u010Dn\u00E9ho poklesu pr\u016Ftoku chlad\u00EDc\u00ED kapaliny."@cs . . "Device for in vivo blood cooling of bigger laboratory animals"@en . . . "tlak 2,5 bar, pr\u016Ftok 800ml, teplota 5-50C" . . "laboratory; animals; blood; cooling; pressure; booster"@en . . . . . "Device was developped for animal experiments as an alternative one to human medicine device (which is much more expensive and complicate. Main function of the device is pressure boosting and flow enhancing through cooling catheter. Side function is measurement of pressure (flow and temperature of cooling fluid. Too low flow of cooling fluid is alarmed."@en . "Z(MSM0021620819)" . . . "P\u0159\u00EDstroj pro in-vivo chlazen\u00ED krve v\u011Bt\u0161\u00EDch laboratorn\u00EDch zv\u00ED\u0159at" . "Universit\u00E4tsklinikum Ulm, Klinik f\u00FCr An\u00E4sthesiologie, Sektion An\u00E4sthesiologische Pathophysiologie und Verfahrensentwicklung, Parkstra\u00DFe 11, 89073 Ulm" . . . "RIV/00216208:11140/10:00300412" . . "Device for in vivo blood cooling of bigger laboratory animals"@en . . "prod\u00E1no za 13tis. Euro" . . .