. "\u0160ed\u00FD, Ji\u0159\u00ED" . "[7EA28A36BCDB]" . . . . "1210-3381" . "Reduction of motion-related artefacts on CBCT scan"@en . . "3"^^ . . . "Role cone-beam CT (CBCT) v zobrazovac\u00EDch metod\u00E1ch \u00FAstn\u00ED a maxilofaci\u00E1ln\u00ED oblasti je dob\u0159e zn\u00E1m\u00E1. Jedn\u00EDm z hlavn\u00EDch probl\u00E9m\u016F, kter\u00E9 zb\u00FDv\u00E1 vy\u0159e\u0161it, je necht\u011Bn\u00FD pohyb pacienta b\u011Bhem skenov\u00E1n\u00ED. V prvn\u00ED \u010D\u00E1sti sd\u011Blen\u00ED je nast\u00EDn\u011Bna problematika vlivu pohybu pacienta na kvalitu obrazu. V druh\u00E9 \u010D\u00E1sti p\u0159edkl\u00E1d\u00E1me p\u016Fvodn\u00ED \u0159e\u0161en\u00ED, jak pohyb pacienta sledovat a jak n\u00E1sledn\u011B eliminovat jeho negativn\u00ED vliv na rozli\u0161en\u00ED CBCT skenu."@cs . . "Folt\u00E1n, Ren\u00E9" . "23" . "CZ - \u010Cesk\u00E1 republika" . . "Role cone-beam CT (CBCT) v zobrazovac\u00EDch metod\u00E1ch \u00FAstn\u00ED a maxilofaci\u00E1ln\u00ED oblasti je dob\u0159e zn\u00E1m\u00E1. Jedn\u00EDm z hlavn\u00EDch probl\u00E9m\u016F, kter\u00E9 zb\u00FDv\u00E1 vy\u0159e\u0161it, je necht\u011Bn\u00FD pohyb pacienta b\u011Bhem skenov\u00E1n\u00ED. V prvn\u00ED \u010D\u00E1sti sd\u011Blen\u00ED je nast\u00EDn\u011Bna problematika vlivu pohybu pacienta na kvalitu obrazu. V druh\u00E9 \u010D\u00E1sti p\u0159edkl\u00E1d\u00E1me p\u016Fvodn\u00ED \u0159e\u0161en\u00ED, jak pohyb pacienta sledovat a jak n\u00E1sledn\u011B eliminovat jeho negativn\u00ED vliv na rozli\u0161en\u00ED CBCT skenu." . . "RIV/00064165:_____/13:10189195!RIV14-MZ0-00064165" . "4"^^ . "The role of cone-beam computed tomography (CBCT) in imaging of the oral and maxillofacial region is well known. One of the biggest problems remaining to be solved is the unwanted movement of the patient during the scanning procedure. In the first part we discuss its influence on image quality. In the second part we present original method how to monitor patient movement and how to eliminate its negative influence on resolution of CBCT scan."@en . "5"^^ . "scan; CBCT; artefacts; motion-related; Reduction"@en . "N, S" . . "LKS: \u010Casopis \u010Cesk\u00E9 stomatologick\u00E9 komory" . "Redukce artefakt\u016F podm\u00EDn\u011Bn\u00FDch pohybem pacienta na CBCT vy\u0161et\u0159en\u00ED" . "Ku\u010Dera, Josef" . "RIV/00064165:_____/13:10189195" . . . . . "Reduction of motion-related artefacts on CBCT scan"@en . . "Redukce artefakt\u016F podm\u00EDn\u011Bn\u00FDch pohybem pacienta na CBCT vy\u0161et\u0159en\u00ED"@cs . "Redukce artefakt\u016F podm\u00EDn\u011Bn\u00FDch pohybem pacienta na CBCT vy\u0161et\u0159en\u00ED"@cs . "Hanzelka, Tom\u00E1\u0161" . . "5" . "Bene\u0161, Ji\u0159\u00ED" . . . . "101860" . "Redukce artefakt\u016F podm\u00EDn\u011Bn\u00FDch pohybem pacienta na CBCT vy\u0161et\u0159en\u00ED" .