"Ov\u011B\u0159en\u00E1 technologie \u2013 monitorovac\u00ED soupravy elektromagnetick\u00E9 st\u00EDnic\u00ED \u00FA\u010Dinnosti QCC/IC-R3 a MF-130D pro kontrolu stavu st\u00EDnic\u00EDch kryt\u016F"@cs . . "Verified Technology \u2013 Electromagnetic shielding effectivenes monitoring sets QCC/IC-R3 and MF-130D for state checking of shielding rooms"@en . "23/2611/001" . . "According to goal of project \u201CSHIELDING \u2013 Monitoring shielding effectiveness degradation and state of the shielding cover\u201D possibilities checking of two monitoring sets: QCC with receiver IC-R3 and MF-130D has been realized. Monitoring sets were fit together from commercial accessible components. There are verified basic technical parameters in both sets by measuring and operational potentialities were designated. Next there are realized practical verification possibilities during shielding effectiveness monitoring of real shielding room. Monitoring sets QCC/IC-R3 was verified for searching electromagnetic energy leakage and for monitoring shielding effectiveness of rooms with shielding effectiveness up to 70 dB. Monitoring sets MF-130D can be used for monitoring shielding effectiveness of highest quality shielding rooms with shielding effectiveness up to 120 dB."@en . . . . "RIV/00000493:G39__/05:#0000003" . "535183" . "P(ONVTUPV200304)" . . . "Ov\u011B\u0159en\u00E1 technologie \u2013 monitorovac\u00ED soupravy elektromagnetick\u00E9 st\u00EDnic\u00ED \u00FA\u010Dinnosti QCC/IC-R3 a MF-130D pro kontrolu stavu st\u00EDnic\u00EDch kryt\u016F" . . . . "Electromagnetic Compatibility; Shielding Room; Shielding Effectivenes (SE); Monitoring SE; Degradation SE; Weapons of Electrical Mass Destruction (WEMD); TEMPEST; IC-R3; QCC; MF-130D"@en . . "Ov\u011B\u0159en\u00E1 technologie \u2013 monitorovac\u00ED soupravy elektromagnetick\u00E9 st\u00EDnic\u00ED \u00FA\u010Dinnosti QCC/IC-R3 a MF-130D pro kontrolu stavu st\u00EDnic\u00EDch kryt\u016F"@cs . "VOP-026 \u0160ternberk, s.p., divize VT\u00DAPV Vy\u0161kov" . . . . "6"^^ . "Such\u00FD, Lubo\u0161" . "Souprava QCC/IC-R3 umo\u017E\u0148uje monitorov\u00E1n\u00ED st\u00EDnic\u00ED \u00FA\u010Dinnosti (SE) kryt\u016F s \u00FAtlumem do 70 dB na kmito\u010Dtech 450 MHz, 900 MHz, 1350 MHz a 1800 MHz. Spr. MF-130D umo\u017E\u0148uje monitorov\u00E1n\u00ED SE na kmito\u010Dtech 10 kHz, 156 kHz, 1 MHz a 10 MHz s rozsahem do 130 dB." . "6"^^ . . . . . "Ov\u011B\u0159en\u00E1 technologie \u2013 monitorovac\u00ED soupravy elektromagnetick\u00E9 st\u00EDnic\u00ED \u00FA\u010Dinnosti QCC/IC-R3 a MF-130D pro kontrolu stavu st\u00EDnic\u00EDch kryt\u016F" . "Ov\u011B\u0159en\u00E9 technologie umo\u017En\u00ED provozovateli zajistit trvale po\u017Eadovan\u00FD stupe\u0148 elektromagnetick\u00E9 ochrany v krytu zasazen\u00E9 techniky a sn\u00ED\u017Eit tak riziko jej\u00EDho provozn\u00EDho vy\u0159azen\u00ED p\u0159i elektromagnetick\u00E9m napaden\u00ED." . "G39" . . . "V\u00E1\u0148a, Vladim\u00EDr" . "RIV/00000493:G39__/05:#0000003!RIV06-MO0-G39_____" . "V souladu s c\u00EDlem \u0159e\u0161en\u00ED projektu \u201EST\u00CDN\u011AN\u00CD - Monitorov\u00E1n\u00ED naru\u0161en\u00ED integrity st\u00EDn\u011Bn\u00ED a stavu st\u00EDnic\u00ED \u00FA\u010Dinnosti st\u00EDnic\u00EDch kryt\u016F\u201C bylo provedeno ov\u011B\u0159en\u00ED mo\u017Enost\u00ED dvou monitorovac\u00EDch souprav \u2013 soupravy vys\u00EDla\u010De QCC s p\u0159ij\u00EDma\u010Dem IC-R3 a soupravy MF-130D sestaven\u00FDch z komer\u010Dn\u011B dostupn\u00FDch komponent\u016F. U obou souprav byly m\u011B\u0159en\u00EDm ov\u011B\u0159eny jejich z\u00E1kladn\u00ED technick\u00E9 parametry a byly stanoveny provozn\u011B technick\u00E9 mo\u017Enosti souprav. D\u00E1le bylo realizov\u00E1no praktick\u00E9 ov\u011B\u0159en\u00ED mo\u017Enost\u00ED souprav p\u0159i monitorov\u00E1n\u00ED st\u00EDnic\u00ED \u00FA\u010Dinnosti re\u00E1ln\u00E9ho st\u00EDnic\u00EDho krytu. U soupravy QCC/IC-R3 byla ov\u011B\u0159ena jej\u00ED pou\u017Eitelnost pro vyhled\u00E1v\u00E1n\u00ED pr\u016Fsak\u016F elektromagnetick\u00E9 energie a pro monitoring SE pro st\u00EDnic\u00ED kryty se st\u00EDnic\u00ED \u00FA\u010Dinnosti do 70 dB, soupravu MF-130D je pak mo\u017Eno pln\u011B vyu\u017E\u00EDt pro monitorov\u00E1n\u00ED i t\u011Bch nejkvalitn\u011Bj\u0161\u00EDch st\u00EDnic\u00EDch kryt\u016F se st\u00EDnic\u00ED \u00FA\u010Dinnost\u00ED do 120 dB"@cs . . . . . . "V souladu s c\u00EDlem \u0159e\u0161en\u00ED projektu \u201EST\u00CDN\u011AN\u00CD - Monitorov\u00E1n\u00ED naru\u0161en\u00ED integrity st\u00EDn\u011Bn\u00ED a stavu st\u00EDnic\u00ED \u00FA\u010Dinnosti st\u00EDnic\u00EDch kryt\u016F\u201C bylo provedeno ov\u011B\u0159en\u00ED mo\u017Enost\u00ED dvou monitorovac\u00EDch souprav \u2013 soupravy vys\u00EDla\u010De QCC s p\u0159ij\u00EDma\u010Dem IC-R3 a soupravy MF-130D sestaven\u00FDch z komer\u010Dn\u011B dostupn\u00FDch komponent\u016F. U obou souprav byly m\u011B\u0159en\u00EDm ov\u011B\u0159eny jejich z\u00E1kladn\u00ED technick\u00E9 parametry a byly stanoveny provozn\u011B technick\u00E9 mo\u017Enosti souprav. D\u00E1le bylo realizov\u00E1no praktick\u00E9 ov\u011B\u0159en\u00ED mo\u017Enost\u00ED souprav p\u0159i monitorov\u00E1n\u00ED st\u00EDnic\u00ED \u00FA\u010Dinnosti re\u00E1ln\u00E9ho st\u00EDnic\u00EDho krytu. U soupravy QCC/IC-R3 byla ov\u011B\u0159ena jej\u00ED pou\u017Eitelnost pro vyhled\u00E1v\u00E1n\u00ED pr\u016Fsak\u016F elektromagnetick\u00E9 energie a pro monitoring SE pro st\u00EDnic\u00ED kryty se st\u00EDnic\u00ED \u00FA\u010Dinnosti do 70 dB, soupravu MF-130D je pak mo\u017Eno pln\u011B vyu\u017E\u00EDt pro monitorov\u00E1n\u00ED i t\u011Bch nejkvalitn\u011Bj\u0161\u00EDch st\u00EDnic\u00EDch kryt\u016F se st\u00EDnic\u00ED \u00FA\u010Dinnost\u00ED do 120 dB" . "[33EC346A9389]" . . "Verified Technology \u2013 Electromagnetic shielding effectivenes monitoring sets QCC/IC-R3 and MF-130D for state checking of shielding rooms"@en .