. . "http://www.isvav.cz/projectDetail.do?rowId=TA04010102"^^ . . "0"^^ . . "Personal microsystem SYMOD for monitoring of vital functions and for monitoring of environment characterised by: \u2022 Detection of ionising radiation \u2013 date: December 2015. \u2022 Detection of gases \u2013 date: December 2015. \u2022 Vital functions monitoring \u2013 date: December 2016. \u2022 Tested and verified microsystem SYMOD \u2013 date: June 2017. Development of electronic and communication means of SYMOD: \u2022 Electronic circuits for working out sensing signals of chosen gases, ionising radiation detector design using a commercial chip, design of electronic circuits for working out ionising radiation detectors: date: December 2016. \u2022 Circuits for working out sensor element signals of the oxygen blood saturation, body temperature, motion activity, circuits for organism physical load monitoring, for taking heart frequency, \u2013 date: December 2016. \u2022 Personal and central unit for gas detection, vital functions monitoring and for radioactive radiation including personal communication and display unit, power management of the personal unit, antenna system of the personal microsystem. Communication interface for integration into the higher monitoring system. Date: December 2016. \u2022 Integration of functional blocs into functional modules \u2013 date: June 2017. \u2022 Functional and long term tests of the microsystem developed \u2013 date: June 2017. \u2022 Development of the microsystem SYMOD production technology: \u2022 Gas sensors \u2013 date: December 2016. \u2022 Living function monitors \u2013 date: June 2017. \u2022 Integration of processing steps including assembly into the textile products \u2013 date: June 2017."@en . . . . "1"^^ . "4"^^ . "0"^^ . . "0"^^ . . . . . . "System for Monitoring and Detection - SYMOD"@en . "2014-10-31+01:00"^^ . . "Osobn\u00ED syst\u00E9m pro monitorov\u00E1n\u00ED \u017Eivotn\u00EDch funkc\u00ED a monitorov\u00E1n\u00ED prost\u0159ed\u00ED, ve kter\u00E9m se vyskytuje osoba chr\u00E1n\u011Bn\u00E1 syst\u00E9mem, charakterizovan\u00FD takto: \u2022 Detekce ionizuj\u00EDc\u00EDho z\u00E1\u0159en\u00ED \u2013 term\u00EDn: prosinec 2015. \u2022 Detekce plyn\u016F \u2013 term\u00EDn: prosinec 2015. \u2022 Monitorov\u00E1n\u00ED \u017Eivotn\u00EDch funkc\u00ED \u2013 term\u00EDn: prosinec 2016. \u2022 Ov\u011B\u0159en\u00FD mikrosyst\u00E9m SYMOD \u2013 term\u00EDn: \u010Derven 2017. Vy\u0159e\u0161en\u00ED elektronick\u00FDch a komunika\u010Dn\u00EDch prost\u0159edk\u016F syst\u00E9mu SYMOD: \u2022 Elektronick\u00E9 obvody pro zpracov\u00E1n\u00ED sign\u00E1l\u016F senzorov\u00FDch element\u016F vybran\u00FDch plyn\u016F, n\u00E1vrh detektoru vn\u011Bj\u0161\u00EDho ionizuj\u00EDc\u00EDho z\u00E1\u0159en\u00ED za vyu\u017Eit\u00ED komer\u010Dn\u00EDho \u010Dipu, n\u00E1vrh elektronick\u00FDch obvod\u016F pro zpracov\u00E1n\u00ED sign\u00E1l\u016F detektor\u016F ionizuj\u00EDc\u00EDho z\u00E1\u0159en\u00ED \u2013 term\u00EDn: prosinec 2016. \u2022 Obvody zpracov\u00E1n\u00ED sign\u00E1lu senzorov\u00FDch element\u016F saturace krve kysl\u00EDkem, t\u011Blesn\u00E9 teploty, pohybov\u00E9 aktivity, monitorov\u00E1n\u00ED fyzick\u00E9 z\u00E1t\u011B\u017Ee organizmu, sn\u00EDm\u00E1n\u00ED tepov\u00E9 frekvence, \u2013 term\u00EDn prosinec: 2016. \u2022 Osobn\u00ED a centr\u00E1ln\u00ED jednotka pro detekci plyn\u016F, fyziologick\u00FDch funkc\u00ED a radioaktivn\u00EDho z\u00E1\u0159en\u00ED zahrnuj\u00EDc\u00ED komunika\u010Dn\u00ED a zobrazovac\u00ED moduly, nap\u00E1jec\u00ED a ant\u00E9nn\u00ED syst\u00E9m \u0159e\u0161en\u00E9ho mikrosyst\u00E9mu. Komunika\u010Dn\u00ED rozhran\u00ED pro integraci do nad\u0159azen\u00E9ho monitorovac\u00EDho syst\u00E9mu \u2013 term\u00EDn: prosinec 2016. \u2022 Integrace jednotliv\u00FDch funk\u010Dn\u00EDch blok\u016F do funk\u010Dn\u00EDch modul\u016F \u2013 term\u00EDn: \u010Derven 2017. \u2022 Funk\u010Dn\u00ED a dlouhodob\u00E9 \u017Eivotnostn\u00ED zkou\u0161ky mikrosyst\u00E9mu \u2013 term\u00EDn: \u010Derven 2017. \u2022 Vy\u0159e\u0161en\u00E1 technologie v\u00FDroby mikrosyst\u00E9mu SYMOD: \u2022 Technologie v\u00FDroby senzor\u016F plyn\u016F \u2013 term\u00EDn: prosinec 2016. \u2022 Technologie v\u00FDroby monitor\u016F \u017Eivotn\u00EDch funkc\u00ED \u2013 term\u00EDn: \u010Derven 2017. \u2022 Integrace d\u00EDl\u010D\u00EDch technologick\u00FDch postup\u016F v\u010Detn\u011B mont\u00E1\u017Ee do textiln\u00EDch v\u00FDrobk\u016F \u2013 term\u00EDn: \u010Derven 2017." . "2015-05-05+02:00"^^ . . . . "2014-07-01+02:00"^^ . . "2017-06-30+02:00"^^ . . "Syst\u00E9m pro monitorov\u00E1n\u00ED a detekci - SYMOD" . "Physiologic body functions- personal monitoring system- gas sensors- motion sensors- ionising radiation- radioactive contamination- terroristic attacks- accidents- environment monitoring- intelligent microsystem- multi sensor approach- intelligent suits"@en . "TA04010102" .