"Wide Area Monitoring syst\u00E9m developed for power distribution network has a top parameters in comparison with foreign systems. The syst\u00E9m includes advanced monitoring and anlysis functions for the distribution and transmission grids."@en . . "V\u00FDzkum a v\u00FDvoj syst\u00E9mu %22Wide Area Monitoring%22 pro oblast distribu\u010Dn\u00ED energetiky" . " Smart Grid" . "The subject of the project is to develop the Wide Area Monitoring System (WAMS) for distribution networks. The system will be used for enhancement of reliability and improvement of safe control of the distribution networks. Another aim is to investigate the possibilities of usage of WAMS technical solutions and functions for future Smart Grid. The WAM system is based on synchronous measurements of phasors using quick sampling with the addition of measurements from another sources. Measurements of voltage and current synchrophasors will be installed in selected places of distribution network within the framework of the developed enhance functions of the system will be verified. The enhance functions are focused to dynamic state estimation of distribution network with planned response of 1s and to on-line parameter identification of the network components. These functions can be used to optimize the system configuration with regards to minimize loss and to maintain system stability."@en . " State Estimation" . " Smart Network" . . "P\u0159edm\u011Btem projektu je v\u00FDzkum a v\u00FDvoj Wide Area Monitoring System (WAMS) pro distribu\u010Dn\u00ED s\u00EDt\u011B. Tento syst\u00E9m bude vyu\u017E\u00EDv\u00E1n pro zv\u00FD\u0161en\u00ED spolehlivosti provozu a bezpe\u010Dnosti \u0159\u00EDzen\u00ED distribu\u010Dn\u00EDch s\u00EDt\u00ED. Sou\u010D\u00E1st\u00ED projektu je pr\u016Fzkum mo\u017Enosti vyu\u017Eit\u00ED technick\u00E9ho \u0159e\u0161en\u00ED a funkc\u00ED WAMS pro budouc\u00ED s\u00EDt\u011B typu Smart Grid.Syst\u00E9m WAM je zalo\u017Een na synchronn\u00EDm m\u011B\u0159en\u00ED f\u00E1zor\u016F s rychl\u00FDm vzorkov\u00E1n\u00EDm, kter\u00E1 jsou dopln\u011Bna o m\u011B\u0159en\u00ED z jin\u00FDch zdroj\u016F. V r\u00E1mci \u0159e\u0161en\u00ED projektu budou pro \u00FA\u010Dely testov\u00E1n\u00ED osazena vybran\u00E1 m\u00EDsta distribu\u010Dn\u00ED s\u00EDt\u011B m\u011B\u0159en\u00EDm f\u00E1zor\u016F nap\u011Bt\u00ED a proud\u016F a budou ov\u011B\u0159eny realizovan\u00E9 vy\u0161\u0161\u00ED funkce.Vy\u0161\u0161\u00ED funkce jsou zam\u011B\u0159eny na dynamickou estimaci stavu distribu\u010Dn\u00ED s\u00EDt\u011B (s pl\u00E1novanou odezvou 1s) a on-line identifikaci parametr\u016F prvk\u016F s\u00EDt\u011B. Tyto funkce bude mo\u017En\u00E9 pou\u017E\u00EDt pro optimalizaci konfigurace soustavy s ohledem na minimalizaci ztr\u00E1t a stabilitu soustavy." . "Wide Area Monitoring; WAM; synchrophasor; Smart Grid; Smart Network; State Estimation; Line Parameter Measurement; Line Temperatur Monitoring; Line Ampacity; Distribution Network Reliability"@en . . " Line Ampacity" . " WAM" . . "2009-03-01+01:00"^^ . " Line Parameter Measurement" . "Wide Area Monitoring" . "http://www.isvav.cz/projectDetail.do?rowId=FR-TI1/462"^^ . . "2012-03-26+02:00"^^ . "0"^^ . . . " synchrophasor" . "1"^^ . . "1"^^ . . "FR-TI1/462" . . "Vyvinut\u00FD syst\u00E9m Wide Area Monitoring pro distribu\u010Dn\u00ED energetiku m\u00E1 \u0161pi\u010Dkov\u00E9 parametry ve srovn\u00E1n\u00ED se syst\u00E9my zahrani\u010Dn\u00EDmi. Syst\u00E9m obsahuje pokro\u010Dil\u00E9 monitorovac\u00ED a analytick\u00E9 tunkce pro distribu\u010Dn\u00ED i p\u0159enosov\u00E9 elektrick\u00E9 s\u00EDt\u011B."@cs . . . . . . "Research and developement of %22Wide Area Monitoring%22 system for distribution energy companies."@en . "2014-07-14+02:00"^^ . "12"^^ . " Line Temperatur Monitoring" . "2012-10-30+01:00"^^ . "12"^^ . . . . .