This HTML5 document contains 51 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n6http://localhost/temp/predkladatel/
n15http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n11http://linked.opendata.cz/resource/domain/vavai/projekt/
n17http://linked.opendata.cz/ontology/domain/vavai/
n5http://linked.opendata.cz/resource/domain/vavai/zamer/
shttp://schema.org/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
skoshttp://www.w3.org/2004/02/skos/core#
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n18http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21670%2F06%3A15128864%21RIV07-GA0-21670___/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n16http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n13http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21670%2F06%3A15128864%21RIV07-GA0-21670___
rdf:type
n17:Vysledek skos:Concept
dcterms:description
The system presented provides an experimental setup with stable position of both X-ray tube and detector and the operational movement of the observed object fixed on a motorized stage. Linear and rotation axes of a computer controlled stage enable radiographic scanning of objects as well as their tomography reconstruction. High quality radiographs are obtained even for very low contrast and low absorption objects thanks to the large dynamic range of the cooled X ray imager together with a proposed beam hardening correction procedure. This procedure is fully automated using a set of the calibration filters and appropriate software modules. Presentované experimentální uspořádání umožňuje pořízení transmisních rentgenových snímků s vysokým kontrastem a velmi dobrým prostorovým rozlišením. Aparatura umožňuje také 3D tomografická měření. The system presented provides an experimental setup with stable position of both X-ray tube and detector and the operational movement of the observed object fixed on a motorized stage. Linear and rotation axes of a computer controlled stage enable radiographic scanning of objects as well as their tomography reconstruction. High quality radiographs are obtained even for very low contrast and low absorption objects thanks to the large dynamic range of the cooled X ray imager together with a proposed beam hardening correction procedure. This procedure is fully automated using a set of the calibration filters and appropriate software modules.
dcterms:title
Experimental System for high resolution X-ray transmission Radiography Experimental System for high resolution X-ray transmission Radiography Experimentální systém pro rentgenovou transmisní radiografii s vysokým rozlišením
skos:prefLabel
Experimental System for high resolution X-ray transmission Radiography Experimental System for high resolution X-ray transmission Radiography Experimentální systém pro rentgenovou transmisní radiografii s vysokým rozlišením
skos:notation
RIV/68407700:21670/06:15128864!RIV07-GA0-21670___
n4:strany
278;281
n4:aktivita
n10:Z n10:P
n4:aktivity
P(1P04LA211), P(GA106/04/0567), Z(AV0Z20710524)
n4:cisloPeriodika
563
n4:dodaniDat
n13:2007
n4:domaciTvurceVysledku
n15:1338226 n15:6189385 n15:3746399 n15:7295642
n4:druhVysledku
n14:J
n4:duvernostUdaju
n7:S
n4:entitaPredkladatele
n18:predkladatel
n4:idSjednocenehoVysledku
475154
n4:idVysledku
RIV/68407700:21670/06:15128864
n4:jazykVysledku
n16:eng
n4:klicovaSlova
Defectoscopy; Pixel detector; Radiography
n4:klicoveSlovo
n12:Radiography n12:Pixel%20detector n12:Defectoscopy
n4:kodStatuVydavatele
NL - Nizozemsko
n4:kontrolniKodProRIV
[3CBD17548194]
n4:nazevZdroje
Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
n4:obor
n19:BG
n4:pocetDomacichTvurcuVysledku
4
n4:pocetTvurcuVysledku
5
n4:projekt
n11:GA106%2F04%2F0567 n11:1P04LA211
n4:rokUplatneniVysledku
n13:2006
n4:svazekPeriodika
2006
n4:tvurceVysledku
Holý, Tomáš Jakůbek, Jan Vavřík, Daniel Vykydal, Zdeněk Jakůbek, M.
n4:zamer
n5:AV0Z20710524
s:issn
0168-9002
s:numberOfPages
4
n6:organizacniJednotka
21670