This HTML5 document contains 47 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n20http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21460%2F12%3A00198284%21RIV13-MSM-21460___/
dctermshttp://purl.org/dc/terms/
n14http://localhost/temp/predkladatel/
n11http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n17http://linked.opendata.cz/resource/domain/vavai/subjekt/
n9http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
rdfshttp://www.w3.org/2000/01/rdf-schema#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n12http://bibframe.org/vocab/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n6http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n19http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n13http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n7http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21460%2F12%3A00198284%21RIV13-MSM-21460___
rdf:type
n9:Vysledek skos:Concept
rdfs:seeAlso
http://www.degruyter.com/view/j/bmte.2012.57.issue-s1-B/bmt-2012-4123/bmt-2012-4123.xml
dcterms:description
The objective of our study was to develop a technique for precise head and shoulder posture measurement or, in other words, for measuring the native position of the head and shoulders in 3D space with accuracy to 1˚. No technique or cheap MoCap camera system has been previously developed that can be widely and easily used in clinical practice. New technique and MoCap system could have important applications, as there are many neurological disorders that af-fect the postural alignment position of the head and shoulders. In many cases, the abnormalities of the head position can be small and difficult to observe. Although an accurate method could contribute to the diagnosis of vestibular disorders and some other disorders, this issue was not systematically studied. MoCap system of head and shoulder posture measurement is based on combination of infrared camera image recognition and evaluation of data recorded by gyroscope. This method was chosen to offer precision less than 1˚ in each angle. The system consists of separate components - a headset equipped by gyro-accelerometer and infrared LEDs, infrared LEDs placed on patient's shoulders, and a stand with two infrared cameras. The first camera is placed above the patient and the other in front of him. Our designed system provides direct information for physicians on the current position of the patient's head and patient's shoulders represented by the angles. Our method is cheaper and offers better application in the field of quantitative as-sessment of head and shoulder posture. The objective of our study was to develop a technique for precise head and shoulder posture measurement or, in other words, for measuring the native position of the head and shoulders in 3D space with accuracy to 1˚. No technique or cheap MoCap camera system has been previously developed that can be widely and easily used in clinical practice. New technique and MoCap system could have important applications, as there are many neurological disorders that af-fect the postural alignment position of the head and shoulders. In many cases, the abnormalities of the head position can be small and difficult to observe. Although an accurate method could contribute to the diagnosis of vestibular disorders and some other disorders, this issue was not systematically studied. MoCap system of head and shoulder posture measurement is based on combination of infrared camera image recognition and evaluation of data recorded by gyroscope. This method was chosen to offer precision less than 1˚ in each angle. The system consists of separate components - a headset equipped by gyro-accelerometer and infrared LEDs, infrared LEDs placed on patient's shoulders, and a stand with two infrared cameras. The first camera is placed above the patient and the other in front of him. Our designed system provides direct information for physicians on the current position of the patient's head and patient's shoulders represented by the angles. Our method is cheaper and offers better application in the field of quantitative as-sessment of head and shoulder posture.
dcterms:title
Motion Capture Camera System for Measurement of Head and Shoulders Position Motion Capture Camera System for Measurement of Head and Shoulders Position
skos:prefLabel
Motion Capture Camera System for Measurement of Head and Shoulders Position Motion Capture Camera System for Measurement of Head and Shoulders Position
skos:notation
RIV/68407700:21460/12:00198284!RIV13-MSM-21460___
n9:predkladatel
n17:orjk%3A21460
n3:aktivita
n4:S
n3:aktivity
S
n3:cisloPeriodika
SI-1
n3:dodaniDat
n7:2013
n3:domaciTvurceVysledku
n11:2086581 n11:3896919 n11:2342391
n3:druhVysledku
n18:J
n3:duvernostUdaju
n8:S
n3:entitaPredkladatele
n20:predkladatel
n3:idSjednocenehoVysledku
151900
n3:idVysledku
RIV/68407700:21460/12:00198284
n3:jazykVysledku
n19:eng
n3:klicovaSlova
head position; shoulders position; neurological diseases; image recognition; accelerometer
n3:klicoveSlovo
n6:accelerometer n6:head%20position n6:shoulders%20position n6:neurological%20diseases n6:image%20recognition
n3:kodStatuVydavatele
US - Spojené státy americké
n3:kontrolniKodProRIV
[7A12D81A2158]
n3:nazevZdroje
Biomedizinische Technik / Biomedical Engineering
n3:obor
n13:JB
n3:pocetDomacichTvurcuVysledku
3
n3:pocetTvurcuVysledku
4
n3:rokUplatneniVysledku
n7:2012
n3:svazekPeriodika
57
n3:tvurceVysledku
Hozman, Jiří Kutílek, Patrik Černý, R. Hejda, Jan
n3:wos
000312675100061
s:issn
0013-5585
s:numberOfPages
4
n12:doi
10.1515/bmt-2012-4123
n14:organizacniJednotka
21460