This HTML5 document contains 42 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n17http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n19http://localhost/temp/predkladatel/
n9http://purl.org/net/nknouf/ns/bibtex#
n7http://linked.opendata.cz/resource/domain/vavai/projekt/
n6http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n18http://linked.opendata.cz/ontology/domain/vavai/
n14https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n20http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21460%2F10%3A00202544%21RIV13-GA0-21460___/
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n12http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n13http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n5http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21460%2F10%3A00202544%21RIV13-GA0-21460___
rdf:type
skos:Concept n18:Vysledek
dcterms:description
Artificial lung ventilation fails in approximately 40 % of cases where patient suffer from ARDS (Acute Respiratory Distress Syndrome). This fact is given both by non-physiological matter of artificial lung ventilation and also by improper ventilation mode. Actual values of mechanical parameters of the respiratory system can be used for determine stability of ventilation mode and for diagnosis of respiratory failure. This study deals with design and verification of non-linear one compartment model of the respiratory system for evaluating mechanical parameters of the respiratory system in real-time. Artificial lung ventilation fails in approximately 40 % of cases where patient suffer from ARDS (Acute Respiratory Distress Syndrome). This fact is given both by non-physiological matter of artificial lung ventilation and also by improper ventilation mode. Actual values of mechanical parameters of the respiratory system can be used for determine stability of ventilation mode and for diagnosis of respiratory failure. This study deals with design and verification of non-linear one compartment model of the respiratory system for evaluating mechanical parameters of the respiratory system in real-time.
dcterms:title
MODELLING OF THE RESPIRATORY SYSTEM USING THE NONLINEAR MODELLING OF THE RESPIRATORY SYSTEM USING THE NONLINEAR
skos:prefLabel
MODELLING OF THE RESPIRATORY SYSTEM USING THE NONLINEAR MODELLING OF THE RESPIRATORY SYSTEM USING THE NONLINEAR
skos:notation
RIV/68407700:21460/10:00202544!RIV13-GA0-21460___
n3:aktivita
n13:P
n3:aktivity
P(GP102/09/P618)
n3:dodaniDat
n5:2013
n3:domaciTvurceVysledku
n6:1457764 n6:3427560
n3:druhVysledku
n8:D
n3:duvernostUdaju
n16:S
n3:entitaPredkladatele
n20:predkladatel
n3:idSjednocenehoVysledku
271983
n3:idVysledku
RIV/68407700:21460/10:00202544
n3:jazykVysledku
n4:eng
n3:klicovaSlova
resistance; frequency
n3:klicoveSlovo
n12:resistance n12:frequency
n3:kontrolniKodProRIV
[D86AD7D08021]
n3:mistoKonaniAkce
Brno
n3:mistoVydani
Brno
n3:nazevZdroje
Analysis of Biomedical Signals and Images, BIOSIGNAL 2010, Proceedings
n3:obor
n15:FS
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
2
n3:projekt
n7:GP102%2F09%2FP618
n3:rokUplatneniVysledku
n5:2010
n3:tvurceVysledku
Roubík, Karel Matějka, Roman
n3:typAkce
n17:EUR
n3:wos
000303723700052
n3:zahajeniAkce
2010-06-27+02:00
s:issn
1211-412X
s:numberOfPages
6
n9:hasPublisher
Vysoké učení technické v Brně
n14:isbn
978-80-214-4106-4
n19:organizacniJednotka
21460