This HTML5 document contains 48 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n11http://localhost/temp/predkladatel/
n13http://linked.opendata.cz/ontology/domain/vavai/
n16http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21340%2F14%3A00227630%21RIV15-MSM-21340___/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n7http://bibframe.org/vocab/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n6http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n17http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n10http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21340%2F14%3A00227630%21RIV15-MSM-21340___
rdf:type
n13:Vysledek skos:Concept
dcterms:description
This paper discusses an intercomparison campaign performed in the mixed radiation field at the CERN-EU (CERF) reference field facility. Various instruments were employed: conventional and extended-range rem counters including a novel instrument called LUPIN, a bubble detector using an active counting system (ABC 1260) and two tissue-equivalent proportional counters (TEPCs). The results show that the extended range instruments agree well within their uncertainties and within 1 sigma with the H*(10) FLUKA value. The conventional rem counters are in good agreement within their uncertainties and underestimate H*(10) as measured by the extended range instruments and as predicted by FLUKA. The TEPCs slightly overestimate the FLUKA value but they are anyhow consistent with it when taking the comparatively large total uncertainties into account, and indicate that the non-neutron part of the stray field accounts for similar to 30 % of the total H*(10). This paper discusses an intercomparison campaign performed in the mixed radiation field at the CERN-EU (CERF) reference field facility. Various instruments were employed: conventional and extended-range rem counters including a novel instrument called LUPIN, a bubble detector using an active counting system (ABC 1260) and two tissue-equivalent proportional counters (TEPCs). The results show that the extended range instruments agree well within their uncertainties and within 1 sigma with the H*(10) FLUKA value. The conventional rem counters are in good agreement within their uncertainties and underestimate H*(10) as measured by the extended range instruments and as predicted by FLUKA. The TEPCs slightly overestimate the FLUKA value but they are anyhow consistent with it when taking the comparatively large total uncertainties into account, and indicate that the non-neutron part of the stray field accounts for similar to 30 % of the total H*(10).
dcterms:title
Instrument intercomparison in the high-energy mixed fieldat the cern-eu reference field (CERF) facility Instrument intercomparison in the high-energy mixed fieldat the cern-eu reference field (CERF) facility
skos:prefLabel
Instrument intercomparison in the high-energy mixed fieldat the cern-eu reference field (CERF) facility Instrument intercomparison in the high-energy mixed fieldat the cern-eu reference field (CERF) facility
skos:notation
RIV/68407700:21340/14:00227630!RIV15-MSM-21340___
n3:aktivita
n17:I
n3:aktivity
I
n3:cisloPeriodika
1-4
n3:dodaniDat
n10:2015
n3:domaciTvurceVysledku
Kubančák, Ján
n3:druhVysledku
n4:J
n3:duvernostUdaju
n8:S
n3:entitaPredkladatele
n16:predkladatel
n3:idSjednocenehoVysledku
22110
n3:idVysledku
RIV/68407700:21340/14:00227630
n3:jazykVysledku
n15:eng
n3:klicovaSlova
NEUTRON REM COUNTER; DETECTORS; RANGE; DOSIMETRY; METERS; WENDI; LINUS
n3:klicoveSlovo
n6:DETECTORS n6:WENDI n6:LINUS n6:RANGE n6:NEUTRON%20REM%20COUNTER n6:METERS n6:DOSIMETRY
n3:kodStatuVydavatele
GB - Spojené království Velké Británie a Severního Irska
n3:kontrolniKodProRIV
[643C659B35E7]
n3:nazevZdroje
Radiation Protection Dosimetry
n3:obor
n12:BG
n3:pocetDomacichTvurcuVysledku
1
n3:pocetTvurcuVysledku
7
n3:rokUplatneniVysledku
n10:2014
n3:svazekPeriodika
161
n3:tvurceVysledku
Silari, M. Kubančák, Ján Manessi, G. P. Caresana, M. Ott, K. Scherpelz, R. Helmecke, M.
n3:wos
000343057600013
s:issn
0144-8420
s:numberOfPages
6
n7:doi
10.1093/rpd/nct312
n11:organizacniJednotka
21340