This HTML5 document contains 49 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n7http://localhost/temp/predkladatel/
n20http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n6http://linked.opendata.cz/resource/domain/vavai/projekt/
n18http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21340%2F13%3A00228835%21RIV15-MSM-21340___/
n15http://linked.opendata.cz/ontology/domain/vavai/
n14http://linked.opendata.cz/resource/domain/vavai/zamer/
shttp://schema.org/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
skoshttp://www.w3.org/2004/02/skos/core#
n16http://bibframe.org/vocab/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n5http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n19http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n13http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21340%2F13%3A00228835%21RIV15-MSM-21340___
rdf:type
skos:Concept n15:Vysledek
dcterms:description
Polyallyldiglycol carbonate-based track-etched detectors can measure linear energy transfer (LET) spectra of charged particles. Accuracy of the spectra is affected by many factors whose effects are difficult to quantify. Typically, only uncertainty arising from the randomness of particle detection is reported in scientific literature. The aim of this paper is to classify the sources of uncertainties of an LET spectrum measurement and provide a simple model for the calculation of the combined uncertainty. The model was used for a spectrum measured with the track-etched detector (Harzlas TD-1) on board of the International Space Station from May-October 2009. For some spectrum bins the largest contribution to the combined uncertainty came from the uncertainty arising from the randomness of particle detection. For other bins it came from the uncertainty of the calibration curve. Contribution from the cross talk between bins was small for most of the bins as the width of the bins was relatively large compared to the intrinsic resolution of the track-etched detector. The analysis showed that sources of uncertainties other than the randomness of particle detection should not, in general, be neglected. (C) 2013 Elsevier B.V. All rights reserved. Polyallyldiglycol carbonate-based track-etched detectors can measure linear energy transfer (LET) spectra of charged particles. Accuracy of the spectra is affected by many factors whose effects are difficult to quantify. Typically, only uncertainty arising from the randomness of particle detection is reported in scientific literature. The aim of this paper is to classify the sources of uncertainties of an LET spectrum measurement and provide a simple model for the calculation of the combined uncertainty. The model was used for a spectrum measured with the track-etched detector (Harzlas TD-1) on board of the International Space Station from May-October 2009. For some spectrum bins the largest contribution to the combined uncertainty came from the uncertainty arising from the randomness of particle detection. For other bins it came from the uncertainty of the calibration curve. Contribution from the cross talk between bins was small for most of the bins as the width of the bins was relatively large compared to the intrinsic resolution of the track-etched detector. The analysis showed that sources of uncertainties other than the randomness of particle detection should not, in general, be neglected. (C) 2013 Elsevier B.V. All rights reserved.
dcterms:title
Uncertainties in linear energy transfer spectra measured with track-etched detectors in space Uncertainties in linear energy transfer spectra measured with track-etched detectors in space
skos:prefLabel
Uncertainties in linear energy transfer spectra measured with track-etched detectors in space Uncertainties in linear energy transfer spectra measured with track-etched detectors in space
skos:notation
RIV/68407700:21340/13:00228835!RIV15-MSM-21340___
n4:aktivita
n11:Z n11:P n11:I
n4:aktivity
I, P(GA205/09/0171), P(GD202/09/H086), P(IAA100480902), P(KJB100480901), Z(AV0Z10480505)
n4:cisloPeriodika
0
n4:dodaniDat
n13:2015
n4:domaciTvurceVysledku
n20:6171281
n4:druhVysledku
n12:J
n4:duvernostUdaju
n10:S
n4:entitaPredkladatele
n18:predkladatel
n4:idSjednocenehoVysledku
112550
n4:idVysledku
RIV/68407700:21340/13:00228835
n4:jazykVysledku
n19:eng
n4:klicovaSlova
CR-39; Linear energy transfer; Uncertainty model; Space dosimetry
n4:klicoveSlovo
n5:CR-39 n5:Space%20dosimetry n5:Uncertainty%20model n5:Linear%20energy%20transfer
n4:kodStatuVydavatele
NL - Nizozemsko
n4:kontrolniKodProRIV
[D0C830B7DE7C]
n4:nazevZdroje
Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
n4:obor
n9:BG
n4:pocetDomacichTvurcuVysledku
1
n4:pocetTvurcuVysledku
4
n4:projekt
n6:GD202%2F09%2FH086 n6:GA205%2F09%2F0171 n6:KJB100480901 n6:IAA100480902
n4:rokUplatneniVysledku
n13:2013
n4:svazekPeriodika
713
n4:tvurceVysledku
Malusek, A. Kolísková, Zlata Brabcova, K. P. Ambrožová, I.
n4:wos
000319239300002
n4:zamer
n14:AV0Z10480505
s:issn
0168-9002
s:numberOfPages
6
n16:doi
10.1016/j.nima.2013.03.012
n7:organizacniJednotka
21340