This HTML5 document contains 47 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n8http://localhost/temp/predkladatel/
n17http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n21http://linked.opendata.cz/resource/domain/vavai/subjekt/
n14http://linked.opendata.cz/ontology/domain/vavai/
n10http://linked.opendata.cz/resource/domain/vavai/zamer/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
rdfshttp://www.w3.org/2000/01/rdf-schema#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n11http://bibframe.org/vocab/
n7http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21340%2F11%3A00173834%21RIV12-MSM-21340___/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n5http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n19http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n15http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21340%2F11%3A00173834%21RIV12-MSM-21340___
rdf:type
n14:Vysledek skos:Concept
rdfs:seeAlso
http://dx.doi.org/10.1093/rpd/ncq491
dcterms:description
The paper deals with the physical skull phantoms Bundesinstitut fuer Strahlenschutz and BPAM-001, which are used in order to calibrate in vivo detection systems for estimation of (241)Am activity in the skeleton. Their voxel models were made and used in the Monte Carlo simulations. The results of the simulation were compared with measurements and reasonable agreement was observed. Several aspects such as materials and source distributions used in the models were discussed. The paper deals with the physical skull phantoms Bundesinstitut fuer Strahlenschutz and BPAM-001, which are used in order to calibrate in vivo detection systems for estimation of (241)Am activity in the skeleton. Their voxel models were made and used in the Monte Carlo simulations. The results of the simulation were compared with measurements and reasonable agreement was observed. Several aspects such as materials and source distributions used in the models were discussed.
dcterms:title
HEAD CALIBRATION PHANTOMS FOR ACTINIDES: MEASUREMENTS AND SIMULATIONS. HEAD CALIBRATION PHANTOMS FOR ACTINIDES: MEASUREMENTS AND SIMULATIONS.
skos:prefLabel
HEAD CALIBRATION PHANTOMS FOR ACTINIDES: MEASUREMENTS AND SIMULATIONS. HEAD CALIBRATION PHANTOMS FOR ACTINIDES: MEASUREMENTS AND SIMULATIONS.
skos:notation
RIV/68407700:21340/11:00173834!RIV12-MSM-21340___
n14:predkladatel
n21:orjk%3A21340
n3:aktivita
n19:Z
n3:aktivity
Z(MSM6840770040)
n3:cisloPeriodika
1-4
n3:dodaniDat
n15:2012
n3:domaciTvurceVysledku
n17:5488915
n3:druhVysledku
n6:J
n3:duvernostUdaju
n4:S
n3:entitaPredkladatele
n7:predkladatel
n3:idSjednocenehoVysledku
201783
n3:idVysledku
RIV/68407700:21340/11:00173834
n3:jazykVysledku
n12:eng
n3:klicovaSlova
in vivo; skull; actinide; monte carlo; simulation; comparison; BPAM-001; measurement; americium
n3:klicoveSlovo
n5:BPAM-001 n5:monte%20carlo n5:simulation n5:comparison n5:americium n5:in%20vivo n5:actinide n5:skull n5:measurement
n3:kodStatuVydavatele
GB - Spojené království Velké Británie a Severního Irska
n3:kontrolniKodProRIV
[8A38B81D1534]
n3:nazevZdroje
Radiation Protection Dosimetry
n3:obor
n18:BG
n3:pocetDomacichTvurcuVysledku
1
n3:pocetTvurcuVysledku
1
n3:rokUplatneniVysledku
n15:2011
n3:svazekPeriodika
144
n3:tvurceVysledku
Vrba, Tomáš
n3:wos
000289164200077
n3:zamer
n10:MSM6840770040
s:issn
0144-8420
s:numberOfPages
4
n11:doi
10.1093/rpd/ncq491
n8:organizacniJednotka
21340