This HTML5 document contains 43 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n16http://localhost/temp/predkladatel/
n11http://linked.opendata.cz/resource/domain/vavai/projekt/
n10http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n6http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n14http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n18http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n13http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n12http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21340%2F08%3A04150075%21RIV09-SUJ-21340___/
n8http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21340%2F08%3A04150075%21RIV09-SUJ-21340___
rdf:type
n6:Vysledek skos:Concept
dcterms:description
The new RAMARN system for radon volume activity measurement was developed in 2003 and has been in use since then. RAMARN consists of a plastic chamber that is conical cylindrical in shape and about 0,5 l in volume; a bare Kodak LR 115 is located on the bottom of this diffusion chamber. The size was chosen to avoid the influence of deposited RnDP. Kodak has a spectrometric character - the tracks are visualized only for alphas with energies between 1 MeV and 3 MeV that touch the foil; thus the effective volume has a lens shape. The response therefore corresponds to diffused radon and half of 218Po born by radon gas decay. The experiments described below were conducted as one part of a routine methodology control, focused on classifying worker irradiation from natural ionizing radiation sources in show caves and in caves used for speleotherapy. Testování přesnosti měření integrálními detektory RAMARN pro potřeby zpřesnění odhadu dávky pro pracovníky v jeskyních proběhlo ve dvou jeskyních po dobu jednoho roku. Výsledky byly implementovány do novelizace metodiky stanovení dávky. The new RAMARN system for radon volume activity measurement was developed in 2003 and has been in use since then. RAMARN consists of a plastic chamber that is conical cylindrical in shape and about 0,5 l in volume; a bare Kodak LR 115 is located on the bottom of this diffusion chamber. The size was chosen to avoid the influence of deposited RnDP. Kodak has a spectrometric character - the tracks are visualized only for alphas with energies between 1 MeV and 3 MeV that touch the foil; thus the effective volume has a lens shape. The response therefore corresponds to diffused radon and half of 218Po born by radon gas decay. The experiments described below were conducted as one part of a routine methodology control, focused on classifying worker irradiation from natural ionizing radiation sources in show caves and in caves used for speleotherapy.
dcterms:title
Stanovení efektivních dávek pro pracovníky jeskyní: experimenty s pasivními detektory Effective Dose Assessment for Workers in Caves in the Czech Republic: Experiments with Passive Radon Detectors Effective Dose Assessment for Workers in Caves in the Czech Republic: Experiments with Passive Radon Detectors
skos:prefLabel
Effective Dose Assessment for Workers in Caves in the Czech Republic: Experiments with Passive Radon Detectors Effective Dose Assessment for Workers in Caves in the Czech Republic: Experiments with Passive Radon Detectors Stanovení efektivních dávek pro pracovníky jeskyní: experimenty s pasivními detektory
skos:notation
RIV/68407700:21340/08:04150075!RIV09-SUJ-21340___
n3:aktivita
n18:P
n3:aktivity
P(JC_12/2006)
n3:cisloPeriodika
1
n3:dodaniDat
n8:2009
n3:domaciTvurceVysledku
n10:2325128
n3:druhVysledku
n15:J
n3:duvernostUdaju
n4:S
n3:entitaPredkladatele
n12:predkladatel
n3:idSjednocenehoVysledku
365330
n3:idVysledku
RIV/68407700:21340/08:04150075
n3:jazykVysledku
n13:eng
n3:klicovaSlova
RAMARN detector; radon; continual monitoring; effective dose
n3:klicoveSlovo
n14:radon n14:continual%20monitoring n14:RAMARN%20detector n14:effective%20dose
n3:kodStatuVydavatele
GB - Spojené království Velké Británie a Severního Irska
n3:kontrolniKodProRIV
[5355C8EFD7DF]
n3:nazevZdroje
Radiation Protection Dosimetry
n3:obor
n17:BG
n3:pocetDomacichTvurcuVysledku
1
n3:pocetTvurcuVysledku
2
n3:projekt
n11:JC_12%2F2006
n3:rokUplatneniVysledku
n8:2008
n3:svazekPeriodika
130
n3:tvurceVysledku
Burian, I. Thinová, Lenka
n3:wos
000259206500012
s:issn
0144-8420
s:numberOfPages
4
n16:organizacniJednotka
21340