This HTML5 document contains 40 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n14http://localhost/temp/predkladatel/
n11http://linked.opendata.cz/resource/domain/vavai/projekt/
n13http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21230%2F12%3A00194803%21RIV13-MSM-21230___/
n8http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n10http://linked.opendata.cz/resource/domain/vavai/subjekt/
n9http://linked.opendata.cz/ontology/domain/vavai/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n6http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n15http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n7http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21230%2F12%3A00194803%21RIV13-MSM-21230___
rdf:type
n9:Vysledek skos:Concept
dcterms:description
Output noise of fluxgate sensors is determined by many parameters, in this contribution we focus on the demagnetization factor of the magnetic material in the fluxgate core. This effect is studied on ring-core tape-wound fluxgates with different diameters of the core and number of tape layers. When optimizing the number of wraps for a 50-mm sensor, we were able to obtain magnetic noise less than 3pT/rtHz at 1 Hz for even for as-cast ribbon. However for 14-mm cores, field annealing was necessary to allow for less than 10pT/rtHz showing that stress effects are significant in this case despite similar demagnetizing factor to 50-mm sensor. Output noise of fluxgate sensors is determined by many parameters, in this contribution we focus on the demagnetization factor of the magnetic material in the fluxgate core. This effect is studied on ring-core tape-wound fluxgates with different diameters of the core and number of tape layers. When optimizing the number of wraps for a 50-mm sensor, we were able to obtain magnetic noise less than 3pT/rtHz at 1 Hz for even for as-cast ribbon. However for 14-mm cores, field annealing was necessary to allow for less than 10pT/rtHz showing that stress effects are significant in this case despite similar demagnetizing factor to 50-mm sensor.
dcterms:title
Effect of Demagnetization and Dimensions of Ring-core Fluxgate Sensor on Output Noise Effect of Demagnetization and Dimensions of Ring-core Fluxgate Sensor on Output Noise
skos:prefLabel
Effect of Demagnetization and Dimensions of Ring-core Fluxgate Sensor on Output Noise Effect of Demagnetization and Dimensions of Ring-core Fluxgate Sensor on Output Noise
skos:notation
RIV/68407700:21230/12:00194803!RIV13-MSM-21230___
n9:predkladatel
n10:orjk%3A21230
n3:aktivita
n15:S n15:P
n3:aktivity
P(7AMB12SK027), P(GD102/09/H082), S
n3:dodaniDat
n7:2013
n3:domaciTvurceVysledku
n8:9294635 n8:9599738 n8:3157644 n8:7555180
n3:druhVysledku
n17:O
n3:duvernostUdaju
n18:S
n3:entitaPredkladatele
n13:predkladatel
n3:idSjednocenehoVysledku
132986
n3:idVysledku
RIV/68407700:21230/12:00194803
n3:jazykVysledku
n12:eng
n3:klicovaSlova
fluxgate; demagnetizing factor
n3:klicoveSlovo
n6:demagnetizing%20factor n6:fluxgate
n3:kontrolniKodProRIV
[217D7C1717AF]
n3:obor
n16:JB
n3:pocetDomacichTvurcuVysledku
4
n3:pocetTvurcuVysledku
5
n3:projekt
n11:7AMB12SK027 n11:GD102%2F09%2FH082
n3:rokUplatneniVysledku
n7:2012
n3:tvurceVysledku
Butvin, P. Janošek, Michal Vyhnánek, Jan Ripka, Pavel Zikmund, Aleš
n14:organizacniJednotka
21230