This HTML5 document contains 42 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n19http://localhost/temp/predkladatel/
n5http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n18http://linked.opendata.cz/resource/domain/vavai/subjekt/
n17http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
rdfshttp://www.w3.org/2000/01/rdf-schema#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n15http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21230%2F12%3A00192891%21RIV13-MSM-21230___/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n16http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n12http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21230%2F12%3A00192891%21RIV13-MSM-21230___
rdf:type
n17:Vysledek skos:Concept
rdfs:seeAlso
http://www.icrepq.com/RE&PQJ-10-13.html
dcterms:description
The paper summarizes basic problems of dimming compatibility of modern LED lamps with the legacy dimming infrastructure. In 2016 the legacy incandescent bulbs are going to be forbidden on the European market and thus it must be replaced by modern and energy efficient solid state lighting. The problems with dimming compatibility appeared. Standards phase-cutting dimmers are widely used in the households and consumers expect the modern lighting to have the same properties as the incandescent bulbs. The legacy dimmers are designed for some minimal load (usually 40 - 60 W) while the modern LED lamps replacements have only about 12 W keeping the 60 W incandescent bulb luminous flux (800 lm). Several different problems must be solved in order to keep the dimming ability, avoid the light flickering and keep the dimmer in the safe operation region. There are two basic dimmer types. The leading edge dimmers that are usually based on triac switch and trailing edge dimmers that use MOSFET switches and electronic control. Both types have its specific demands and need different approach for ensuring the dimming compatibility. New LED driver must be developed in order to be compatible with the legacy dimmers. The paper summarizes basic problems of dimming compatibility of modern LED lamps with the legacy dimming infrastructure. In 2016 the legacy incandescent bulbs are going to be forbidden on the European market and thus it must be replaced by modern and energy efficient solid state lighting. The problems with dimming compatibility appeared. Standards phase-cutting dimmers are widely used in the households and consumers expect the modern lighting to have the same properties as the incandescent bulbs. The legacy dimmers are designed for some minimal load (usually 40 - 60 W) while the modern LED lamps replacements have only about 12 W keeping the 60 W incandescent bulb luminous flux (800 lm). Several different problems must be solved in order to keep the dimming ability, avoid the light flickering and keep the dimmer in the safe operation region. There are two basic dimmer types. The leading edge dimmers that are usually based on triac switch and trailing edge dimmers that use MOSFET switches and electronic control. Both types have its specific demands and need different approach for ensuring the dimming compatibility. New LED driver must be developed in order to be compatible with the legacy dimmers.
dcterms:title
Dimming Compatibility of 60W Replacement LED Lamps with Legacy Dimming Infrastructure Dimming Compatibility of 60W Replacement LED Lamps with Legacy Dimming Infrastructure
skos:prefLabel
Dimming Compatibility of 60W Replacement LED Lamps with Legacy Dimming Infrastructure Dimming Compatibility of 60W Replacement LED Lamps with Legacy Dimming Infrastructure
skos:notation
RIV/68407700:21230/12:00192891!RIV13-MSM-21230___
n17:predkladatel
n18:orjk%3A21230
n3:aktivita
n6:R
n3:aktivity
R
n3:cisloPeriodika
10
n3:dodaniDat
n12:2013
n3:domaciTvurceVysledku
n5:8536112 n5:8532214
n3:druhVysledku
n7:J
n3:duvernostUdaju
n10:S
n3:entitaPredkladatele
n15:predkladatel
n3:idSjednocenehoVysledku
131383
n3:idVysledku
RIV/68407700:21230/12:00192891
n3:jazykVysledku
n16:eng
n3:klicovaSlova
Incandescent 60 W replacement; Dimming compatibility; Solid State Lighting; Leading edge; Trailing edge
n3:klicoveSlovo
n4:Dimming%20compatibility n4:Leading%20edge n4:Solid%20State%20Lighting n4:Trailing%20edge n4:Incandescent%2060%20W%20replacement
n3:kodStatuVydavatele
ES - Španělské království
n3:kontrolniKodProRIV
[8FA42D9AC7CB]
n3:nazevZdroje
Renewable Energies & Power Quality Journal (RE&PQJ)
n3:obor
n8:JA
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
2
n3:rokUplatneniVysledku
n12:2012
n3:svazekPeriodika
2012
n3:tvurceVysledku
Husák, Miroslav Bouřa, Adam
s:issn
2172-038X
s:numberOfPages
4
n19:organizacniJednotka
21230