This HTML5 document contains 48 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n15http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n17http://localhost/temp/predkladatel/
n8http://purl.org/net/nknouf/ns/bibtex#
n5http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n7http://linked.opendata.cz/ontology/domain/vavai/
n12https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n10http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21230%2F07%3A03131189%21RIV08-MSM-21230___/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n13http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n18http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n20http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n11http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21230%2F07%3A03131189%21RIV08-MSM-21230___
rdf:type
n7:Vysledek skos:Concept
dcterms:description
Spontaneous ultra-weak photon emission in the visible range was measured on palm and dorsal side of left and right hand by means of a low noise photomultiplier system. To study the dynamics of this photon emission in a 24h period photon emission was recorded in 2h intervals in 5 experiments, utilizing strict protocols for dark adaptation and recording of subjects. Mean photon emission over the 24h period differed both between subjects and hand locations. To detect a pattern in the fluctuations the mean value for each location of each subject in each experiment was utilized to calculate fluctuations during the course of 24h for each anatomical location. The fluctuations in photon emission in the course of 24h were more at dorsal sides than palm sides. Photon emission at the left dorsal location was high at night, while the right dorsal side emitted most during the day. Daily rhytm in photon emission can be recorded from both the dorsal and palm sides of the hands. Spontanni utra-slaba emise fotonu ve viditelne oblasti byla zmerena na dlani a dorzalni strane leve a prave ruky pomoci nizko sumoveho fotonasobice. K studiu dynamiky teto emise fotonu v prubehu 24 hodin, emise fotonu byla merena v intervalech 2 hodin v 5 experimentech s vyuzitim prisneho protokolu adaptaci v tme a mereni subjektu. Prumerna intenzita emise fotonu v rozsahu 24 hodin se lisila jak mezi subjekty tak i mezi merenymi lokacemi. K detekci typickeho profilu intenzity emise, prumerna hodnota z jednotlivych lokaci a subjektu v kazdem mereni byla vyuzita na spocitani fluktuaci emise v prubehu 24 hodin pro kazdou lokaci.Fluktuace inetzity emise fotonu v prubehu 24 byly vyssi na dorzalni stranach ruk nez na dlanich. Emise fotonu na levy dorzalni strane byla vyssi v noci, na pravy dorzalni strane byla emise vyssi pocas dne. Denni rytmus emise fotonu se da zmerit z dorzalni strany i dlane obou ruk. Spontaneous ultra-weak photon emission in the visible range was measured on palm and dorsal side of left and right hand by means of a low noise photomultiplier system. To study the dynamics of this photon emission in a 24h period photon emission was recorded in 2h intervals in 5 experiments, utilizing strict protocols for dark adaptation and recording of subjects. Mean photon emission over the 24h period differed both between subjects and hand locations. To detect a pattern in the fluctuations the mean value for each location of each subject in each experiment was utilized to calculate fluctuations during the course of 24h for each anatomical location. The fluctuations in photon emission in the course of 24h were more at dorsal sides than palm sides. Photon emission at the left dorsal location was high at night, while the right dorsal side emitted most during the day. Daily rhytm in photon emission can be recorded from both the dorsal and palm sides of the hands.
dcterms:title
Measurement of Spontaneous Ultra-Weak Photon Emission Froma Human Body: Spontaneous Ultra-Weak Photon Emission Varies Diurnally Měření spontánní ultra slabé emise fotonu z lidského těla: Spontánní emise fotonu se počas dne mění Measurement of Spontaneous Ultra-Weak Photon Emission Froma Human Body: Spontaneous Ultra-Weak Photon Emission Varies Diurnally
skos:prefLabel
Measurement of Spontaneous Ultra-Weak Photon Emission Froma Human Body: Spontaneous Ultra-Weak Photon Emission Varies Diurnally Měření spontánní ultra slabé emise fotonu z lidského těla: Spontánní emise fotonu se počas dne mění Measurement of Spontaneous Ultra-Weak Photon Emission Froma Human Body: Spontaneous Ultra-Weak Photon Emission Varies Diurnally
skos:notation
RIV/68407700:21230/07:03131189!RIV08-MSM-21230___
n4:strany
421;424
n4:aktivita
n16:S
n4:aktivity
S
n4:dodaniDat
n11:2008
n4:domaciTvurceVysledku
n5:4936914
n4:druhVysledku
n19:D
n4:duvernostUdaju
n9:S
n4:entitaPredkladatele
n10:predkladatel
n4:idSjednocenehoVysledku
432500
n4:idVysledku
RIV/68407700:21230/07:03131189
n4:jazykVysledku
n18:eng
n4:klicovaSlova
biophoton; biophotonics; hand dorsum; palm; ultra-weak photon emission
n4:klicoveSlovo
n13:palm n13:hand%20dorsum n13:biophotonics n13:biophoton n13:ultra-weak%20photon%20emission
n4:kontrolniKodProRIV
[3AA6ECC8005E]
n4:mistoKonaniAkce
Smolenice
n4:mistoVydani
Bratislava
n4:nazevZdroje
Proceedings Measurement 2007
n4:obor
n20:JA
n4:pocetDomacichTvurcuVysledku
1
n4:pocetTvurcuVysledku
5
n4:rokUplatneniVysledku
n11:2007
n4:tvurceVysledku
Wijk, R. Cifra, Michal Wijk, E. Koch, H. Bosman, S.
n4:typAkce
n15:WRD
n4:zahajeniAkce
2007-05-20+02:00
s:numberOfPages
4
n8:hasPublisher
Ústav merania SAV
n12:isbn
978-80-969672-0-9
n17:organizacniJednotka
21230