This HTML5 document contains 47 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n15http://localhost/temp/predkladatel/
n16http://linked.opendata.cz/resource/domain/vavai/projekt/
n9http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n20http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
rdfshttp://www.w3.org/2000/01/rdf-schema#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n14http://bibframe.org/vocab/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n18http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21220%2F13%3A00213547%21RIV15-MSM-21220___/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n17http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n13http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n11http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21220%2F13%3A00213547%21RIV15-MSM-21220___
rdf:type
skos:Concept n20:Vysledek
rdfs:seeAlso
http://www.degruyter.com/view/j/mecdc.2013.11.issue-2/mecdc-2013-0009/mecdc-2013-0009.xml
dcterms:description
Particulate matter (PM) is considered to be the most harmful component of internal combustion engine exhaust to human health. At decreasing levels of total PM mass, its measurement is challenging, requiring either a full-flow dilution tunnel or a fast-response, variable dilution ratio sampler. To allow for such measurements on the road and in lesser equipped laboratories, a low-cost proportional sampling system has been developed. The system uses a pair of mass flow controllers, one of which meters filtered air into a heated miniature partial-flow dilution tunnel, and the other one regulates the flow of diluted exhaust through a filter on which PM is sampled. Results obtained with this system during transient tests fall, after corrections for measurement bias, within a factor of two of measurement obtained with a full-flow dilution tunnel. Particulate matter (PM) is considered to be the most harmful component of internal combustion engine exhaust to human health. At decreasing levels of total PM mass, its measurement is challenging, requiring either a full-flow dilution tunnel or a fast-response, variable dilution ratio sampler. To allow for such measurements on the road and in lesser equipped laboratories, a low-cost proportional sampling system has been developed. The system uses a pair of mass flow controllers, one of which meters filtered air into a heated miniature partial-flow dilution tunnel, and the other one regulates the flow of diluted exhaust through a filter on which PM is sampled. Results obtained with this system during transient tests fall, after corrections for measurement bias, within a factor of two of measurement obtained with a full-flow dilution tunnel.
dcterms:title
Assessment of a Low-Cost Portable Proportional Exhaust Sampling System for Gravimetric Particulate Matter Emissions Measurement Assessment of a Low-Cost Portable Proportional Exhaust Sampling System for Gravimetric Particulate Matter Emissions Measurement
skos:prefLabel
Assessment of a Low-Cost Portable Proportional Exhaust Sampling System for Gravimetric Particulate Matter Emissions Measurement Assessment of a Low-Cost Portable Proportional Exhaust Sampling System for Gravimetric Particulate Matter Emissions Measurement
skos:notation
RIV/68407700:21220/13:00213547!RIV15-MSM-21220___
n4:aktivita
n7:P n7:V
n4:aktivity
P(ED2.1.00/03.0125), V
n4:cisloPeriodika
2
n4:dodaniDat
n11:2015
n4:domaciTvurceVysledku
n9:5758602
n4:druhVysledku
n19:J
n4:duvernostUdaju
n12:S
n4:entitaPredkladatele
n18:predkladatel
n4:idSjednocenehoVysledku
62248
n4:idVysledku
RIV/68407700:21220/13:00213547
n4:jazykVysledku
n17:eng
n4:klicovaSlova
internal combustion engine; exhaust emissions; particulate matter; particulate mass; gravimetric method; proportional sampling; on-board measurement; low-cost; PEMS
n4:klicoveSlovo
n5:PEMS n5:internal%20combustion%20engine n5:particulate%20mass n5:low-cost n5:particulate%20matter n5:on-board%20measurement n5:proportional%20sampling n5:exhaust%20emissions n5:gravimetric%20method
n4:kodStatuVydavatele
CZ - Česká republika
n4:kontrolniKodProRIV
[C6103D36A466]
n4:nazevZdroje
MECCA Journal of Middle European Construction and Design of Cars
n4:obor
n13:JT
n4:pocetDomacichTvurcuVysledku
1
n4:pocetTvurcuVysledku
2
n4:projekt
n16:ED2.1.00%2F03.0125
n4:rokUplatneniVysledku
n11:2013
n4:svazekPeriodika
11
n4:tvurceVysledku
Vojtíšek, Michal Pechout, M.
s:issn
1214-0821
s:numberOfPages
7
n14:doi
10.2478/mecdc-2013-0009
n15:organizacniJednotka
21220