This HTML5 document contains 40 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n21http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
n16http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21220%2F12%3A00200919%21RIV13-MSM-21220___/
dctermshttp://purl.org/dc/terms/
n13http://purl.org/net/nknouf/ns/bibtex#
n12http://localhost/temp/predkladatel/
n15http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n8http://linked.opendata.cz/resource/domain/vavai/subjekt/
n7http://linked.opendata.cz/ontology/domain/vavai/
n9https://schema.org/
shttp://schema.org/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/
rdfshttp://www.w3.org/2000/01/rdf-schema#
skoshttp://www.w3.org/2004/02/skos/core#
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n6http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n22http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n19http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n20http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n18http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21220%2F12%3A00200919%21RIV13-MSM-21220___
rdf:type
n7:Vysledek skos:Concept
rdfs:seeAlso
http://stc.fs.cvut.cz
dcterms:description
The main aim of the research work is to describe temperature and velocity fields above the panel radiator fitted with non-standard (or design) covering grids with various flow cross-section and the subsequent effect at an air flow throughout the room. The effect of flow cross-section and shape of openings of panel radiators covering grids at their heat output was determined experimentally. The other experiment dealt with description of velocity field above the covering grid, using the method of particle image velocimetry (PIV). The results are presented in a graphic form as a heat output decrease depending on parameters of the covering grid and in the form of velocity vectors placed in two orthogonal planes. Based on experimentally obtained data, the mathematical model will be verified. Then a computer fluid dynamics (CFD) will be used to simulate both temperature and velocity fields above the panel radiator and in the room. The main aim of the research work is to describe temperature and velocity fields above the panel radiator fitted with non-standard (or design) covering grids with various flow cross-section and the subsequent effect at an air flow throughout the room. The effect of flow cross-section and shape of openings of panel radiators covering grids at their heat output was determined experimentally. The other experiment dealt with description of velocity field above the covering grid, using the method of particle image velocimetry (PIV). The results are presented in a graphic form as a heat output decrease depending on parameters of the covering grid and in the form of velocity vectors placed in two orthogonal planes. Based on experimentally obtained data, the mathematical model will be verified. Then a computer fluid dynamics (CFD) will be used to simulate both temperature and velocity fields above the panel radiator and in the room.
dcterms:title
The reduction of convective heat output at panel radiators The reduction of convective heat output at panel radiators
skos:prefLabel
The reduction of convective heat output at panel radiators The reduction of convective heat output at panel radiators
skos:notation
RIV/68407700:21220/12:00200919!RIV13-MSM-21220___
n7:predkladatel
n8:orjk%3A21220
n5:aktivita
n19:S
n5:aktivity
S
n5:dodaniDat
n18:2013
n5:domaciTvurceVysledku
n15:4913035
n5:druhVysledku
n14:D
n5:duvernostUdaju
n22:S
n5:entitaPredkladatele
n16:predkladatel
n5:idSjednocenehoVysledku
164495
n5:idVysledku
RIV/68407700:21220/12:00200919
n5:jazykVysledku
n10:eng
n5:klicovaSlova
free convection; panel radiator; covering grid
n5:klicoveSlovo
n6:free%20convection n6:covering%20grid n6:panel%20radiator
n5:kontrolniKodProRIV
[FF0014480724]
n5:mistoKonaniAkce
Praha
n5:mistoVydani
Praha
n5:nazevZdroje
Sborník STČ 2012
n5:obor
n20:JE
n5:pocetDomacichTvurcuVysledku
1
n5:pocetTvurcuVysledku
1
n5:rokUplatneniVysledku
n18:2012
n5:tvurceVysledku
Heis, Václav
n5:typAkce
n21:CST
n5:zahajeniAkce
2012-03-28+02:00
s:numberOfPages
10
n13:hasPublisher
České vysoké učení technické v Praze. Fakulta strojní
n9:isbn
978-80-01-04796-5
n12:organizacniJednotka
21220