This HTML5 document contains 44 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n8http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n19http://purl.org/net/nknouf/ns/bibtex#
n16http://localhost/temp/predkladatel/
n7http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n10http://linked.opendata.cz/resource/domain/vavai/subjekt/
n9http://linked.opendata.cz/ontology/domain/vavai/
n5https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
rdfshttp://www.w3.org/2000/01/rdf-schema#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n21http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n22http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n14http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21220%2F12%3A00193790%21RIV13-MSM-21220___/
n20http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21220%2F12%3A00193790%21RIV13-MSM-21220___
rdf:type
skos:Concept n9:Vysledek
rdfs:seeAlso
http://akce.fs.vsb.cz/2012/asr2012/Sbornik-ASR2012.pdf
dcterms:description
This contribution describes a method for creating visualization of biomass fired boiler at the Faculty of Mechanical Engineering, Czech Technical University in Prague, Department of Power Engineering. The biomass fired boiler is a common boiler equipped with additional instrumentation allowing to measure necessary combustion process information. We created the visualizations and control interface for boiler control to allow its easier control. The visualization and control interface is created in the software Wondervare InTouch, which is one of the most popular SCADA/HMI software worldwide. For experimental purposes, the boiler control algorithm is divided into two parts, the first one runs in the programmable controller WinCon, the second one runs in the environment Simulink of program Matlab. So, we need not only WinCon to be connected to the control interface, also Simulink needs to be connected to it. One way for communication between the devices is the widely used communication standard OPC. Another way is to establish a connection using a standard DDE, which is used for dynamic data exchange between applications on one computer. Both ways are compared in the contribution. This contribution describes a method for creating visualization of biomass fired boiler at the Faculty of Mechanical Engineering, Czech Technical University in Prague, Department of Power Engineering. The biomass fired boiler is a common boiler equipped with additional instrumentation allowing to measure necessary combustion process information. We created the visualizations and control interface for boiler control to allow its easier control. The visualization and control interface is created in the software Wondervare InTouch, which is one of the most popular SCADA/HMI software worldwide. For experimental purposes, the boiler control algorithm is divided into two parts, the first one runs in the programmable controller WinCon, the second one runs in the environment Simulink of program Matlab. So, we need not only WinCon to be connected to the control interface, also Simulink needs to be connected to it. One way for communication between the devices is the widely used communication standard OPC. Another way is to establish a connection using a standard DDE, which is used for dynamic data exchange between applications on one computer. Both ways are compared in the contribution.
dcterms:title
Visualization of Biomass Fired Boiler Visualization of Biomass Fired Boiler
skos:prefLabel
Visualization of Biomass Fired Boiler Visualization of Biomass Fired Boiler
skos:notation
RIV/68407700:21220/12:00193790!RIV13-MSM-21220___
n9:predkladatel
n10:orjk%3A21220
n3:aktivita
n11:S
n3:aktivity
S
n3:dodaniDat
n20:2013
n3:domaciTvurceVysledku
n7:6347118 n7:7730764
n3:druhVysledku
n22:D
n3:duvernostUdaju
n17:S
n3:entitaPredkladatele
n14:predkladatel
n3:idSjednocenehoVysledku
177576
n3:idVysledku
RIV/68407700:21220/12:00193790
n3:jazykVysledku
n21:eng
n3:klicovaSlova
boiler; control; interface; OPC; DDE
n3:klicoveSlovo
n4:control n4:boiler n4:DDE n4:interface n4:OPC
n3:kontrolniKodProRIV
[E38DEE1FFD80]
n3:mistoKonaniAkce
Ostrava
n3:mistoVydani
Ostrava
n3:nazevZdroje
XXXVI. Seminar ASR '2012 %22Instruments and Control%22
n3:obor
n18:JB
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
2
n3:rokUplatneniVysledku
n20:2012
n3:tvurceVysledku
Kubera, Milan Vrána, Stanislav
n3:typAkce
n8:EUR
n3:zahajeniAkce
2012-04-27+02:00
s:numberOfPages
4
n19:hasPublisher
Vysoká škola báňská - Technická univerzita Ostrava
n5:isbn
978-80-248-2626-4
n16:organizacniJednotka
21220