This HTML5 document contains 54 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n16http://localhost/temp/predkladatel/
n7http://linked.opendata.cz/resource/domain/vavai/projekt/
n5http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n21http://linked.opendata.cz/ontology/domain/vavai/riv/podDruhVysledku/
n19http://linked.opendata.cz/ontology/domain/vavai/
n18http://linked.opendata.cz/resource/domain/vavai/zamer/
n8http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21220%2F10%3A00170696%21RIV11-MSM-21220___/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n13http://linked.opendata.cz/ontology/domain/vavai/riv/licencniPoplatek/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n20http://linked.opendata.cz/ontology/domain/vavai/riv/kategorie/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/vyuzitiJinymSubjektem/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n12http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n15http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21220%2F10%3A00170696%21RIV11-MSM-21220___
rdf:type
skos:Concept n19:Vysledek
dcterms:description
Zařízení umožňuje namáhat páteřní segment 2-3 obratlů dle výsledků získaných z měření in-vivo pomocí moderních zobrazovacích metod. Trajektorie pohybu krajních obratlů je popsána pomocí okamžitých středů otáčení. Mechanismus je určen pro měření v kombinaci se zařízeními pro kinematickou analýzu jako je VICON, QUALISYS, atd. Pevný support definuje globální souřadný systém. S minimem 3 markerů na každé tělo obratle je možné stanovit lokální systémy a sledovat změny v pohybových parametrech při stejném zatížení před a po implementaci meziobratlových náhrad v různých pozicích vzhledem k pozici %22optimální%22. Vzniklo v rámci řešení tématického úkolu TÚ A2.2 MSM6840770012 - Transdisciplinární výzkum v oblasti biomedicínského inženýrství II. Uživatelem výsledku je ČVUT v Praze. Zařízení umožňuje namáhat páteřní segment 2-3 obratlů dle výsledků získaných z měření in-vivo pomocí moderních zobrazovacích metod. Trajektorie pohybu krajních obratlů je popsána pomocí okamžitých středů otáčení. Mechanismus je určen pro měření v kombinaci se zařízeními pro kinematickou analýzu jako je VICON, QUALISYS, atd. Pevný support definuje globální souřadný systém. S minimem 3 markerů na každé tělo obratle je možné stanovit lokální systémy a sledovat změny v pohybových parametrech při stejném zatížení před a po implementaci meziobratlových náhrad v různých pozicích vzhledem k pozici %22optimální%22. Vzniklo v rámci řešení tématického úkolu TÚ A2.2 MSM6840770012 - Transdisciplinární výzkum v oblasti biomedicínského inženýrství II. Uživatelem výsledku je ČVUT v Praze. Device allows loading of spinal functional unit of 2 to 3 vertebrae based on in-vivo measurements and its results using modern imaging devices. Motion trajectory of the most distant vertebrae is described in the form of instantaneous axis of rotation. Device is intended for measuring in combination with motion capture devices such as VICON, QUALISYS etc. Rigid construction support defines the global coordinate system. With minimum of 3 markers for each vertebral body, the spatial coordinate system can be easily defined and any changes in kinematic parameters of the movement in the same loading scheme can be calculated. This system is used for analysis of the artificial intervertebral disc prosthesis and the influence of various positions with respect to the optimal position. The result has been created within the scope of thematic task TU A2.2 MSM6840770012 - Transdisciplinary research in the field of biomedical engineering II. The specimen is used by CTU in Prague.
dcterms:title
The loading mechanism for the kinematic analysis of spinal segments in vitro Zatěžovací mechanismus pro kinematickou analýzu páteřních segmentů in-vitro Zatěžovací mechanismus pro kinematickou analýzu páteřních segmentů in-vitro
skos:prefLabel
Zatěžovací mechanismus pro kinematickou analýzu páteřních segmentů in-vitro Zatěžovací mechanismus pro kinematickou analýzu páteřních segmentů in-vitro The loading mechanism for the kinematic analysis of spinal segments in vitro
skos:notation
RIV/68407700:21220/10:00170696!RIV11-MSM-21220___
n3:aktivita
n12:Z n12:S n12:P
n3:aktivity
P(FT-TA3/131), S, Z(MSM6840770012)
n3:dodaniDat
n15:2011
n3:domaciTvurceVysledku
n5:2638312 n5:5078237 n5:7792530 n5:7411839
n3:druhVysledku
n21:G%2FB
n3:duvernostUdaju
n11:S
n3:ekonomickeParametry
Cena 25 000 Kč
n3:entitaPredkladatele
n8:predkladatel
n3:idSjednocenehoVysledku
299708
n3:idVysledku
RIV/68407700:21220/10:00170696
n3:interniIdentifikace
12105-P06-2010.10
n3:jazykVysledku
n4:cze
n3:kategorie
n20:A
n3:klicovaSlova
Spinal biomechanics; Spine; Kinematic analysis; Instantaneous axis of rotation; Intervertebral disc
n3:klicoveSlovo
n9:Kinematic%20analysis n9:Intervertebral%20disc n9:Spine n9:Spinal%20biomechanics n9:Instantaneous%20axis%20of%20rotation
n3:kontrolniKodProRIV
[BE69982BCC96]
n3:licencniPoplatek
n13:Z
n3:lokalizaceVysledku
Katedra anatomie a biomechaniky FTVS UK, Jose Martino 31, Praha 6, laboratoř Extremních zátěží (BEZ)
n3:obor
n14:ED
n3:pocetDomacichTvurcuVysledku
4
n3:pocetTvurcuVysledku
5
n3:projekt
n7:FT-TA3%2F131
n3:rokUplatneniVysledku
n15:2010
n3:technickeParametry
rozměry základového roštu 1,3 x 0,9m. Vlastníkem výsledku je ČVUT v Praze, IČ 68407700.
n3:tvurceVysledku
Kuželka, Jiří Kronek, Jakub Holub, Ondřej Otáhal, S. Otáhal, Martin
n3:vlastnik
n8:vlastnikVysledku
n3:vyuzitiJinymSubjektem
n17:P
n3:zamer
n18:MSM6840770012
n16:organizacniJednotka
21220