This HTML5 document contains 45 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n9http://localhost/temp/predkladatel/
n11http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n16http://linked.opendata.cz/ontology/domain/vavai/
n8http://linked.opendata.cz/resource/domain/vavai/zamer/
n13http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21220%2F07%3A02134259%21RIV08-MSM-21220___/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n5http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n6http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n12http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n15http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21220%2F07%3A02134259%21RIV08-MSM-21220___
rdf:type
n16:Vysledek skos:Concept
dcterms:description
Capillary tube expansion devices are widely used in refrigeration equipment; nevertheless, the mechanism of the flow is still not fully described and understood, so the experimental verification of most predictions is still necessary. A modified numerical model of capillary flow has been developed both for standard refrigerants and with emphasis for saturated fluorocarbon (C2F2n+2) refrigerants. Capillary tube expansion devices are widely used in refrigeration equipment; nevertheless, the mechanism of the flow is still not fully described and understood, so the experimental verification of most predictions is still necessary. A modified numerical model of capillary flow has been developed both for standard refrigerants and with emphasis for saturated fluorocarbon (C2F2n+2) refrigerants. Není k dispozici
dcterms:title
Studie kapilárního toku pro okruhy pracující se saturovanými fluoroinertními chladivy A Study of the Flow through Capillary Tubes Tuned for a Cooling Circuit with Saturated Fluorocarbon Refrigerants A Study of the Flow through Capillary Tubes Tuned for a Cooling Circuit with Saturated Fluorocarbon Refrigerants
skos:prefLabel
A Study of the Flow through Capillary Tubes Tuned for a Cooling Circuit with Saturated Fluorocarbon Refrigerants A Study of the Flow through Capillary Tubes Tuned for a Cooling Circuit with Saturated Fluorocarbon Refrigerants Studie kapilárního toku pro okruhy pracující se saturovanými fluoroinertními chladivy
skos:notation
RIV/68407700:21220/07:02134259!RIV08-MSM-21220___
n5:strany
1490;1508
n5:aktivita
n10:Z
n5:aktivity
Z(MSM6840770035)
n5:cisloPeriodika
5
n5:dodaniDat
n15:2008
n5:domaciTvurceVysledku
n11:4843657 n11:6112137
n5:druhVysledku
n14:J
n5:duvernostUdaju
n18:S
n5:entitaPredkladatele
n13:predkladatel
n5:idSjednocenehoVysledku
408231
n5:idVysledku
RIV/68407700:21220/07:02134259
n5:jazykVysledku
n12:eng
n5:klicovaSlova
capillary tube; cooling circuit; fluorocarbon refrigerant; model comparisons; two-phase flow
n5:klicoveSlovo
n6:capillary%20tube n6:cooling%20circuit n6:fluorocarbon%20refrigerant n6:model%20comparisons n6:two-phase%20flow
n5:kodStatuVydavatele
US - Spojené státy americké
n5:kontrolniKodProRIV
[42F12DC50472]
n5:nazevZdroje
International Journal of Thermophysics
n5:obor
n17:BJ
n5:pocetDomacichTvurcuVysledku
2
n5:pocetTvurcuVysledku
2
n5:rokUplatneniVysledku
n15:2007
n5:svazekPeriodika
28
n5:tvurceVysledku
Vinš, Václav Vacek, Václav
n5:zamer
n8:MSM6840770035
s:issn
0195-928X
s:numberOfPages
19
n9:organizacniJednotka
21220