This HTML5 document contains 44 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n13http://localhost/temp/predkladatel/
n10http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n19http://linked.opendata.cz/ontology/domain/vavai/
n17http://linked.opendata.cz/resource/domain/vavai/zamer/
n11https://schema.org/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/kodPristupu/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n15http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21220%2F06%3A02122856%21RIV07-MSM-21220___/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n18http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n16http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21220%2F06%3A02122856%21RIV07-MSM-21220___
rdf:type
skos:Concept n19:Vysledek
dcterms:description
Rychlost pulzní vlny (PWV) v cévách je jedním z důležitých hemodynamických parametrů pro stanovení stavu tepen. V naší laboratoři je PWV sledována v pružných trubicích která se svými vlastnostmi podobají tepnám. Metoda je založená na neinvazivním optickém měření radiálního posunutí stěny trubice vlivem průchodu PWV. Je používána vysokofrekvenční kamera s vysokým rozlišením obrazu. Získána data byla vyhodnocena několika na sobě nezávislými metodami a výsledky byly porovnány. Detekované PWV byli stejných řádových hodnot jako teoreticky vypočtené PWV a publikované fyziologické hodnoty. The pulse wave velocity (PWV) in blood vessels is one of the important hemodynamical parameters for detection of artery health condition. In our laboratory, the PWV in elastic tubes and arteries is measured in vitro. The method is based on optical measurements of displacement of the pulsating tube wall. A high frame rate camera was used. The obtained data were evaluated by several methods and compared. The measured pulse wave velocities were in the same order of magnitude as values based on theoretical calculations and published physiological data. The pulse wave velocity (PWV) in blood vessels is one of the important hemodynamical parameters for detection of artery health condition. In our laboratory, the PWV in elastic tubes and arteries is measured in vitro. The method is based on optical measurements of displacement of the pulsating tube wall. A high frame rate camera was used. The obtained data were evaluated by several methods and compared. The measured pulse wave velocities were in the same order of magnitude as values based on theoretical calculations and published physiological data.
dcterms:title
Experimental measurement of pulse wave velocity in elastic tube Experimental measurement of pulse wave velocity in elastic tube Experimentální měření pulzní vlny v elastické trubici
skos:prefLabel
Experimental measurement of pulse wave velocity in elastic tube Experimental measurement of pulse wave velocity in elastic tube Experimentální měření pulzní vlny v elastické trubici
skos:notation
RIV/68407700:21220/06:02122856!RIV07-MSM-21220___
n3:aktivita
n18:Z
n3:aktivity
Z(MSM6840770012)
n3:dodaniDat
n16:2007
n3:domaciTvurceVysledku
n10:6532012 n10:7011717 n10:3948137 n10:1885812
n3:druhVysledku
n12:A
n3:duvernostUdaju
n5:S
n3:entitaPredkladatele
n15:predkladatel
n3:idSjednocenehoVysledku
475111
n3:idVysledku
RIV/68407700:21220/06:02122856
n3:jazykVysledku
n14:eng
n3:klicovaSlova
biomechanics; elastic tube; pulse wave velocity
n3:klicoveSlovo
n6:pulse%20wave%20velocity n6:elastic%20tube n6:biomechanics
n3:kodPristupu
n7:L
n3:kontrolniKodProRIV
[EF5DC7D6ADEE]
n3:mistoVydani
Praha
n3:nosic
neuvedeno
n3:obor
n8:BO
n3:pocetDomacichTvurcuVysledku
4
n3:pocetTvurcuVysledku
4
n3:rokUplatneniVysledku
n16:2006
n3:tvurceVysledku
Macková, Hana Žitný, Rudolf Konvičková, Svatava Chlup, Hynek
n3:zamer
n17:MSM6840770012
n11:isbn
80-86246-27-2
n13:organizacniJednotka
21220