This HTML5 document contains 40 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n13http://localhost/temp/predkladatel/
n16http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n18http://linked.opendata.cz/resource/domain/vavai/subjekt/
n17http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21110%2F12%3A00194347%21RIV13-MSM-21110___/
n4http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/
skoshttp://www.w3.org/2004/02/skos/core#
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n6http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n15http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n8http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21110%2F12%3A00194347%21RIV13-MSM-21110___
rdf:type
n4:Vysledek skos:Concept
dcterms:description
An electrical apparatus for measuring moisture content was developed by our laboratory and uses dependence of electrical properties on water content in studied material. Error analysis of the apparatus was run by measuring different volumes of water in a simplified specimen, i.e. hollow plexiglass block, in order to avoid as many side-effects as possible. Obtained data were processed using both basic and advanced statistics and results were compared with each other. The influence of water content on accuracy of measured data was studied as well as the influence of variation of apparatus' proper arrangement or factual methodics of its usage. The overall coefficient of variation was 4%. There was no trend found in results of error dependence on water content. Comparison with current surveys led to a conclusion, that the studied apparatus can be used for indirect measurement of water content in porous materials, with expectable error and under known conditions. Factual experiments with porous materials are not involved, but are currently under investigation. An electrical apparatus for measuring moisture content was developed by our laboratory and uses dependence of electrical properties on water content in studied material. Error analysis of the apparatus was run by measuring different volumes of water in a simplified specimen, i.e. hollow plexiglass block, in order to avoid as many side-effects as possible. Obtained data were processed using both basic and advanced statistics and results were compared with each other. The influence of water content on accuracy of measured data was studied as well as the influence of variation of apparatus' proper arrangement or factual methodics of its usage. The overall coefficient of variation was 4%. There was no trend found in results of error dependence on water content. Comparison with current surveys led to a conclusion, that the studied apparatus can be used for indirect measurement of water content in porous materials, with expectable error and under known conditions. Factual experiments with porous materials are not involved, but are currently under investigation.
dcterms:title
Error Analysis Of Nonconventional Electrical Moisture-meter Under Simplified Conditions Error Analysis Of Nonconventional Electrical Moisture-meter Under Simplified Conditions
skos:prefLabel
Error Analysis Of Nonconventional Electrical Moisture-meter Under Simplified Conditions Error Analysis Of Nonconventional Electrical Moisture-meter Under Simplified Conditions
skos:notation
RIV/68407700:21110/12:00194347!RIV13-MSM-21110___
n4:predkladatel
n18:orjk%3A21110
n5:aktivita
n7:S
n5:aktivity
S
n5:cisloPeriodika
67
n5:dodaniDat
n8:2013
n5:domaciTvurceVysledku
n16:2724448 n16:9948953
n5:druhVysledku
n9:J
n5:duvernostUdaju
n11:S
n5:entitaPredkladatele
n17:predkladatel
n5:idSjednocenehoVysledku
134693
n5:idVysledku
RIV/68407700:21110/12:00194347
n5:jazykVysledku
n15:eng
n5:klicovaSlova
device; capacitance method; error analysis; moisture meter
n5:klicoveSlovo
n6:error%20analysis n6:device n6:capacitance%20method n6:moisture%20meter
n5:kodStatuVydavatele
US - Spojené státy americké
n5:kontrolniKodProRIV
[81A2E81B1ACA]
n5:nazevZdroje
Proceedings of World Academy of Science, Engineering and Technology
n5:obor
n12:JN
n5:pocetDomacichTvurcuVysledku
2
n5:pocetTvurcuVysledku
2
n5:rokUplatneniVysledku
n8:2012
n5:svazekPeriodika
6
n5:tvurceVysledku
Ďurana, Kamil Černý, Robert
s:issn
2010-376X
s:numberOfPages
4
n13:organizacniJednotka
21110