This HTML5 document contains 43 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n6http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n18http://purl.org/net/nknouf/ns/bibtex#
n17http://localhost/temp/predkladatel/
n11http://linked.opendata.cz/resource/domain/vavai/projekt/
n5http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n3http://linked.opendata.cz/ontology/domain/vavai/
n19http://linked.opendata.cz/resource/domain/vavai/zamer/
n8https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n14http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21110%2F02%3A07085248%21RIV%2F2003%2FGA0%2F211103%2FN/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n7http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n21http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n13http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n22http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n20http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21110%2F02%3A07085248%21RIV%2F2003%2FGA0%2F211103%2FN
rdf:type
n3:Vysledek skos:Concept
dcterms:description
Load bearing capacity of the masonry depends on several parameters to which belog a degree of saturation by water. In the laboratory conditions influence of moisture, thickness of horizontal layer and strength of mortar was conducted in order to estimatethe deformation characteristics of masonry, as well. Load bearing capacity of the masonry depends on several parameters to which belog a degree of saturation by water. In the laboratory conditions influence of moisture, thickness of horizontal layer and strength of mortar was conducted in order to estimatethe deformation characteristics of masonry, as well.
dcterms:title
LOAD BEARING CAPACITY OF WET MASONRY LOAD BEARING CAPACITY OF WET MASONRY
skos:prefLabel
LOAD BEARING CAPACITY OF WET MASONRY LOAD BEARING CAPACITY OF WET MASONRY
skos:notation
RIV/68407700:21110/02:07085248!RIV/2003/GA0/211103/N
n4:strany
582;583
n4:aktivita
n13:Z n13:P
n4:aktivity
P(GA103/99/0941), Z(MSM 210000004)
n4:dodaniDat
n20:2003
n4:domaciTvurceVysledku
n5:4550498
n4:druhVysledku
n22:D
n4:duvernostUdaju
n15:S
n4:entitaPredkladatele
n14:predkladatel
n4:idSjednocenehoVysledku
651964
n4:idVysledku
RIV/68407700:21110/02:07085248
n4:jazykVysledku
n21:eng
n4:klicovaSlova
load bearing; wet masonry
n4:klicoveSlovo
n7:load%20bearing n7:wet%20masonry
n4:kontrolniKodProRIV
[83BCE5705939]
n4:mistoKonaniAkce
Praha
n4:mistoVydani
Praha
n4:nazevZdroje
Proceedings of Workshop 2002
n4:obor
n12:JN
n4:pocetDomacichTvurcuVysledku
4
n4:pocetTvurcuVysledku
4
n4:pocetUcastnikuAkce
0
n4:pocetZahranicnichUcastnikuAkce
0
n4:projekt
n11:GA103%2F99%2F0941
n4:rokUplatneniVysledku
n20:2002
n4:tvurceVysledku
Klečka, Tomáš
n4:typAkce
n6:EUR
n4:zahajeniAkce
2002-02-11+01:00
n4:zamer
n19:MSM%20210000004
s:numberOfPages
2
n18:hasPublisher
České vysoké učení technické v Praze
n8:isbn
80-01-02511-X
n17:organizacniJednotka
21110