This HTML5 document contains 47 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n21http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n15http://localhost/temp/predkladatel/
n10http://purl.org/net/nknouf/ns/bibtex#
n17http://linked.opendata.cz/resource/domain/vavai/projekt/
n9http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n16http://linked.opendata.cz/ontology/domain/vavai/
n18https://schema.org/
n7http://linked.opendata.cz/resource/domain/vavai/zamer/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n14http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n13http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n12http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68407700%3A21110%2F02%3A01075089%21RIV%2F2003%2FGA0%2F211103%2FN/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n20http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n11http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68407700%3A21110%2F02%3A01075089%21RIV%2F2003%2FGA0%2F211103%2FN
rdf:type
n16:Vysledek skos:Concept
dcterms:description
Thermal conductivity, specific heat and linear thermal expansion coefficient are measured in the temperature range from 100 C to 800 C and in the moisture range from dry material to saturation water content. Linear hygric expansion coefficient is measured in the whole moisture range from dry material to full water saturation. Moisture diffusivity is measured as a function of temperature up to 80 C, and the effects of high-temperature exposure up to 800 C and freeze/thaw cycles on its value are studied. In order to analyze the observed changes in moisture diffusivity and thermal parameters, thermal analysis and visual analysis are performed. As the main reason for these changes, the crack formation is identified. Particularly, the magnitude of variations of moisture diffusivity is found to be affected by the quality of aggregates rather than by the quality of cement Thermal conductivity, specific heat and linear thermal expansion coefficient are measured in the temperature range from 100 C to 800 C and in the moisture range from dry material to saturation water content. Linear hygric expansion coefficient is measured in the whole moisture range from dry material to full water saturation. Moisture diffusivity is measured as a function of temperature up to 80 C, and the effects of high-temperature exposure up to 800 C and freeze/thaw cycles on its value are studied. In order to analyze the observed changes in moisture diffusivity and thermal parameters, thermal analysis and visual analysis are performed. As the main reason for these changes, the crack formation is identified. Particularly, the magnitude of variations of moisture diffusivity is found to be affected by the quality of aggregates rather than by the quality of cement
dcterms:title
Hygric and Thermal Properties of HPC for Concrete Containments of Nuclear Power Plants Hygric and Thermal Properties of HPC for Concrete Containments of Nuclear Power Plants
skos:prefLabel
Hygric and Thermal Properties of HPC for Concrete Containments of Nuclear Power Plants Hygric and Thermal Properties of HPC for Concrete Containments of Nuclear Power Plants
skos:notation
RIV/68407700:21110/02:01075089!RIV/2003/GA0/211103/N
n4:strany
765;774
n4:aktivita
n6:Z n6:P
n4:aktivity
P(GV103/97/K003), Z(MSM 210000004)
n4:dodaniDat
n11:2003
n4:domaciTvurceVysledku
n9:8834253
n4:druhVysledku
n20:D
n4:duvernostUdaju
n13:S
n4:entitaPredkladatele
n12:predkladatel
n4:idSjednocenehoVysledku
648173
n4:idVysledku
RIV/68407700:21110/02:01075089
n4:jazykVysledku
n19:eng
n4:klicovaSlova
HPC; containment; linear thermal expansion coefficient; moisture diffusivity; specific heat; thermal conductivity
n4:klicoveSlovo
n14:linear%20thermal%20expansion%20coefficient n14:thermal%20conductivity n14:specific%20heat n14:containment n14:HPC n14:moisture%20diffusivity
n4:kontrolniKodProRIV
[E0E4DDDBB149]
n4:mistoKonaniAkce
Dundee, Scotland
n4:mistoVydani
London
n4:nazevZdroje
Concrete for Extreme Conditions
n4:obor
n5:JI
n4:pocetDomacichTvurcuVysledku
3
n4:pocetTvurcuVysledku
4
n4:pocetUcastnikuAkce
0
n4:pocetZahranicnichUcastnikuAkce
0
n4:projekt
n17:GV103%2F97%2FK003
n4:rokUplatneniVysledku
n11:2002
n4:tvurceVysledku
Drchalová, Jaroslava
n4:typAkce
n21:WRD
n4:zahajeniAkce
2002-09-09+02:00
n4:zamer
n7:MSM%20210000004
s:numberOfPages
10
n10:hasPublisher
Thomas Telford Publishing
n18:isbn
0-7277-3178-5
n15:organizacniJednotka
21110