This HTML5 document contains 48 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n13http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n20http://purl.org/net/nknouf/ns/bibtex#
n11http://linked.opendata.cz/resource/domain/vavai/projekt/
n5http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n8http://linked.opendata.cz/resource/domain/vavai/subjekt/
n7http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n15http://bibframe.org/vocab/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n16http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
n19http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68378271%3A_____%2F13%3A00423888%21RIV14-MSM-68378271/
xsdhhttp://www.w3.org/2001/XMLSchema#
n9http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n21http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n17http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68378271%3A_____%2F13%3A00423888%21RIV14-MSM-68378271
rdf:type
n7:Vysledek skos:Concept
dcterms:description
The Ring Imaging Cherenkov detector (RICH) of the COMPASS experiment at CERN is key tool for particle identification.Two reflecting spherical mirror surfaces, covering a total area of about 21 m2, hosted in the radiator vessel,provide Cherenkov radiation focusing to photon detectors.These ones are based on the use of multi-anode photo-multiplier tubes.They are coupled to individual lens telescopes, made from special fused silica aspherical lenses. Design, construction, and Hartmann test of lenses qualities and alignment were described. The RICH detector uses C4F10 as radiator gas. The refractive index of the radiator gas is substantial parameter.It varies with temperature, atmospheric pressure and gas purity.Its accurate knowledge is essential for the particle identification performance.A modified Jamin’s interferometer was proposed,constructed and tested to allow on-line refractive index measurement with accuracy better than 10-6.The new types of fused silica Cherenkov radiators was The Ring Imaging Cherenkov detector (RICH) of the COMPASS experiment at CERN is key tool for particle identification.Two reflecting spherical mirror surfaces, covering a total area of about 21 m2, hosted in the radiator vessel,provide Cherenkov radiation focusing to photon detectors.These ones are based on the use of multi-anode photo-multiplier tubes.They are coupled to individual lens telescopes, made from special fused silica aspherical lenses. Design, construction, and Hartmann test of lenses qualities and alignment were described. The RICH detector uses C4F10 as radiator gas. The refractive index of the radiator gas is substantial parameter.It varies with temperature, atmospheric pressure and gas purity.Its accurate knowledge is essential for the particle identification performance.A modified Jamin’s interferometer was proposed,constructed and tested to allow on-line refractive index measurement with accuracy better than 10-6.The new types of fused silica Cherenkov radiators was
dcterms:title
New optics for resolution improving of Ring Imaging Cherenkov detectors New optics for resolution improving of Ring Imaging Cherenkov detectors
skos:prefLabel
New optics for resolution improving of Ring Imaging Cherenkov detectors New optics for resolution improving of Ring Imaging Cherenkov detectors
skos:notation
RIV/68378271:_____/13:00423888!RIV14-MSM-68378271
n7:predkladatel
n8:ico%3A68378271
n3:aktivita
n4:I n4:P
n3:aktivity
I, P(ED2.1.00/03.0079), P(LA08015)
n3:dodaniDat
n17:2014
n3:domaciTvurceVysledku
n5:5441196
n3:druhVysledku
n10:D
n3:duvernostUdaju
n18:S
n3:entitaPredkladatele
n19:predkladatel
n3:idSjednocenehoVysledku
91640
n3:idVysledku
RIV/68378271:_____/13:00423888
n3:jazykVysledku
n9:eng
n3:klicovaSlova
Cherenkov radiation; Optical device; Hartmann test
n3:klicoveSlovo
n16:Optical%20device n16:Cherenkov%20radiation n16:Hartmann%20test
n3:kontrolniKodProRIV
[D97CD3718368]
n3:mistoKonaniAkce
Liberec
n3:mistoVydani
Cedex
n3:nazevZdroje
EPJ Web of Conferences: International Conference on Optics and Measurement, OAM 2012
n3:obor
n21:BH
n3:pocetDomacichTvurcuVysledku
1
n3:pocetTvurcuVysledku
6
n3:projekt
n11:ED2.1.00%2F03.0079 n11:LA08015
n3:rokUplatneniVysledku
n17:2013
n3:tvurceVysledku
Steiger, Lukáš Šulc, Miroslav Kramer, Daniel Slunecka, M. Polák, Jaroslav Finger, M.
n3:typAkce
n13:WRD
n3:wos
000326985500023
n3:zahajeniAkce
2012-10-16+02:00
s:issn
2100-014X
s:numberOfPages
4
n15:doi
10.1051/epjconf/20134800024
n20:hasPublisher
EDP Sciences