This HTML5 document contains 51 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n14http://linked.opendata.cz/resource/domain/vavai/projekt/
n11http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n19http://linked.opendata.cz/resource/domain/vavai/subjekt/
n16http://linked.opendata.cz/ontology/domain/vavai/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/podDruhVysledku/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n13http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68081731%3A_____%2F12%3A00387396%21RIV13-GA0-68081731/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/kategorie/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/vyuzitiJinymSubjektem/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n18http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n6http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68081731%3A_____%2F12%3A00387396%21RIV13-GA0-68081731
rdf:type
skos:Concept n16:Vysledek
dcterms:description
Zařízení umožňuje ve zpětnovazební smyčce stabilizovat repetiční frekvenci pulsního laseru podle přesného radiofrekvenčního normálu (H-maser, oscilátor řízený podle GPS apod.) Proces zpracování vysokofrekvenčního signálu a regulace repetiční frekvence je plně digitální. Vysokofrekvenční signál z rychlého fotodetektoru monitorujícího výstup pulsního laseru je po digitalizaci v reálném čase zpracováván algoritmy softwarově definovaného rádia realizujícími digitální filtraci, decimaci, fázovou demodulaci a zpětnovazební regulaci repetiční frekvence. Vzorkovací frekvence vstupní digitalizační karty je nastavitelná v rozsahu 10 – 250 MHz, zpracovávat je možné vstupní signály v rozsahu 0 – 120 MHz. Vzorkovací frekvence digitálního P-S-D regulátoru a výstupního regulačního signálu je nastavitelná v rozsahu 10 – 1000 Hz. Při typické aplikaci, kdy je 100MHz repetiční frekvence femtosekundového pulsního laseru stabilizována podle 10MHz radiofrekvenčního normálu, je směrodatná odchylka v řádu 10-3 Hz. Zařízení umožňuje ve zpětnovazební smyčce stabilizovat repetiční frekvenci pulsního laseru podle přesného radiofrekvenčního normálu (H-maser, oscilátor řízený podle GPS apod.) Proces zpracování vysokofrekvenčního signálu a regulace repetiční frekvence je plně digitální. Vysokofrekvenční signál z rychlého fotodetektoru monitorujícího výstup pulsního laseru je po digitalizaci v reálném čase zpracováván algoritmy softwarově definovaného rádia realizujícími digitální filtraci, decimaci, fázovou demodulaci a zpětnovazební regulaci repetiční frekvence. Vzorkovací frekvence vstupní digitalizační karty je nastavitelná v rozsahu 10 – 250 MHz, zpracovávat je možné vstupní signály v rozsahu 0 – 120 MHz. Vzorkovací frekvence digitálního P-S-D regulátoru a výstupního regulačního signálu je nastavitelná v rozsahu 10 – 1000 Hz. Při typické aplikaci, kdy je 100MHz repetiční frekvence femtosekundového pulsního laseru stabilizována podle 10MHz radiofrekvenčního normálu, je směrodatná odchylka v řádu 10-3 Hz. The developed device is intended for closed-loop locking of the repetition frequency of a pulse laser to a precise radiofrequency reference (H-maser, GPS disciplined oscillator etc.) Radiofrequency signal processing and repetition frequency control are fully digital. The RF signal from a fast photo detector monitoring the output of the laser is processed using software-defined radio algorithms performing digital filtration, phase demodulation and closed-loop control of the repetition frequency. Sampling frequency of the input RF signal digitizer can be set from 10 to 250 MHz. Signals in the 0 – 120 MHz band can be processed. The sampling frequency of the digital P-S-D controller and the output control signal can be set from 10 to 1000 Hz. In a typical application, which involves stabilizing the repetition frequency to 100 MHz with respect to a 10MHz RF reference, the standard deviation is in 10-3Hz order of magnitude.
dcterms:title
Jednotka pro stabilizaci repetiční frekvence pulsního laseru využívající softwarově definované rádio Jednotka pro stabilizaci repetiční frekvence pulsního laseru využívající softwarově definované rádio iny: Unit for stabilizing pulse laser repetition frequency based on software defined rádio
skos:prefLabel
iny: Unit for stabilizing pulse laser repetition frequency based on software defined rádio Jednotka pro stabilizaci repetiční frekvence pulsního laseru využívající softwarově definované rádio Jednotka pro stabilizaci repetiční frekvence pulsního laseru využívající softwarově definované rádio
skos:notation
RIV/68081731:_____/12:00387396!RIV13-GA0-68081731
n16:predkladatel
n19:ico%3A68081731
n3:aktivita
n15:I n15:P
n3:aktivity
I, P(GAP102/10/1813), P(GPP102/11/P819)
n3:dodaniDat
n6:2013
n3:domaciTvurceVysledku
n11:2062976 n11:9233598 n11:5629802 n11:5467853 n11:2430320
n3:druhVysledku
n9:G%2FB
n3:duvernostUdaju
n12:S
n3:ekonomickeParametry
Funkční vzorek laboratorního zařízení nutného pro další vývoj, který byl realizovaný při řešení grantu s předpokladem budoucího využití v optických laboratořích ÚPT AV ČR, v. v. i.
n3:entitaPredkladatele
n13:predkladatel
n3:idSjednocenehoVysledku
143683
n3:idVysledku
RIV/68081731:_____/12:00387396
n3:interniIdentifikace
UPT 2012/05
n3:jazykVysledku
n18:cze
n3:kategorie
n4:A
n3:klicovaSlova
pulse laser.; stabilization; SDR; software-defined radio
n3:klicoveSlovo
n10:SDR n10:software-defined%20radio n10:pulse%20laser. n10:stabilization
n3:kontrolniKodProRIV
[8A3074160769]
n3:obor
n17:BH
n3:pocetDomacichTvurcuVysledku
5
n3:pocetTvurcuVysledku
5
n3:projekt
n14:GPP102%2F11%2FP819 n14:GAP102%2F10%2F1813
n3:rokUplatneniVysledku
n6:2012
n3:technickeParametry
Funkční vzorek realizovaný v rámci řešení grantu: Vzorkovací frekvence 10 – 250 MHz, vstupní signál 0 – 120 MHz.
n3:tvurceVysledku
Čížek, Martin Hrabina, Jan Číp, Ondřej Lazar, Josef Buchta, Zdeněk
n3:vlastnik
n13:vlastnikVysledku
n3:vyuzitiJinymSubjektem
n8:N