This HTML5 document contains 40 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n13http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n16http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n14http://bibframe.org/vocab/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n15http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F68081715%3A_____%2F14%3A00431472%21RIV15-AV0-68081715/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n8http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n11http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F68081715%3A_____%2F14%3A00431472%21RIV15-AV0-68081715
rdf:type
skos:Concept n16:Vysledek
dcterms:description
Rapid and sensitive determination of peroxyacetyl nitrate (PAN) in air based on a chemiluminescence reaction with an alkaline solution of luminol in the chemiluminescence aerosol detector is described. The limit of detection is 14.9 ng/m3 (3 ppt) of PAN. Alternatively, the PAN after separation is detected simultaneously with NO2. The limit of detection is 50 ppt of PAN and 50 ppt of NO2. The time resolution is 3 min. Rapid and sensitive determination of peroxyacetyl nitrate (PAN) in air based on a chemiluminescence reaction with an alkaline solution of luminol in the chemiluminescence aerosol detector is described. The limit of detection is 14.9 ng/m3 (3 ppt) of PAN. Alternatively, the PAN after separation is detected simultaneously with NO2. The limit of detection is 50 ppt of PAN and 50 ppt of NO2. The time resolution is 3 min.
dcterms:title
Detection of peroxyacetyl nitrate in air using chemiluminescence aerosol detector Detection of peroxyacetyl nitrate in air using chemiluminescence aerosol detector
skos:prefLabel
Detection of peroxyacetyl nitrate in air using chemiluminescence aerosol detector Detection of peroxyacetyl nitrate in air using chemiluminescence aerosol detector
skos:notation
RIV/68081715:_____/14:00431472!RIV15-AV0-68081715
n3:aktivita
n8:I
n3:aktivity
I
n3:cisloPeriodika
11
n3:dodaniDat
n11:2015
n3:domaciTvurceVysledku
n13:9512160 n13:7752849
n3:druhVysledku
n10:J
n3:duvernostUdaju
n12:S
n3:entitaPredkladatele
n15:predkladatel
n3:idSjednocenehoVysledku
10631
n3:idVysledku
RIV/68081715:_____/14:00431472
n3:jazykVysledku
n4:eng
n3:klicovaSlova
peroxyacetylnitrate; chemiluminescence; air
n3:klicoveSlovo
n9:chemiluminescence n9:peroxyacetylnitrate n9:air
n3:kodStatuVydavatele
SK - Slovenská republika
n3:kontrolniKodProRIV
[1BC2A935E47F]
n3:nazevZdroje
Chemical Papers
n3:obor
n17:CB
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
3
n3:rokUplatneniVysledku
n11:2014
n3:svazekPeriodika
68
n3:tvurceVysledku
Bružeňák, L. Večeřa, Zbyněk Mikuška, Pavel
n3:wos
000341735100006
s:issn
0366-6352
s:numberOfPages
9
n14:doi
10.2478/s11696-014-0607-x