This HTML5 document contains 44 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n16http://localhost/temp/predkladatel/
n4http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n14http://linked.opendata.cz/resource/domain/vavai/subjekt/
n13http://linked.opendata.cz/ontology/domain/vavai/
n15http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F61989100%3A27360%2F13%3A86088217%21RIV14-MSM-27360___/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n8http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n17http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n12http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F61989100%3A27360%2F13%3A86088217%21RIV14-MSM-27360___
rdf:type
skos:Concept n13:Vysledek
dcterms:description
The non-reciprocity of magneto-optical reflection response by surface plasmon excitation in the planar systems with prism coupling is studied. These structures are intended as the sensor units combining magneto-optical and surface-plasmon-resonance effects. To simulate the response of discussed structures to external magnetic field theoretical model based on matrix algorithm is applied. The ability of MO-SPR systems to sensing of magnetic field is verified using proposed response factors. Obtained theoretical results expressed by introduced sensitivity criteria are confirmed by experiments realized by Multiscope device. The non-reciprocity of magneto-optical reflection response by surface plasmon excitation in the planar systems with prism coupling is studied. These structures are intended as the sensor units combining magneto-optical and surface-plasmon-resonance effects. To simulate the response of discussed structures to external magnetic field theoretical model based on matrix algorithm is applied. The ability of MO-SPR systems to sensing of magnetic field is verified using proposed response factors. Obtained theoretical results expressed by introduced sensitivity criteria are confirmed by experiments realized by Multiscope device.
dcterms:title
Magneto-plasmonics as a tool for magnetic field sensing Magneto-plasmonics as a tool for magnetic field sensing
skos:prefLabel
Magneto-plasmonics as a tool for magnetic field sensing Magneto-plasmonics as a tool for magnetic field sensing
skos:notation
RIV/61989100:27360/13:86088217!RIV14-MSM-27360___
n13:predkladatel
n14:orjk%3A27360
n3:aktivita
n7:V n7:I
n3:aktivity
I, V
n3:cisloPeriodika
9
n3:dodaniDat
n12:2014
n3:domaciTvurceVysledku
n4:9907734 n4:5882087
n3:druhVysledku
n10:J
n3:duvernostUdaju
n9:S
n3:entitaPredkladatele
n15:predkladatel
n3:idSjednocenehoVysledku
85755
n3:idVysledku
RIV/61989100:27360/13:86088217
n3:jazykVysledku
n17:eng
n3:klicovaSlova
Response factors; Sensors; Magneto-optics; Plasmon resonance
n3:klicoveSlovo
n8:Plasmon%20resonance n8:Magneto-optics n8:Sensors n8:Response%20factors
n3:kodStatuVydavatele
CZ - Česká republika
n3:kontrolniKodProRIV
[AEFD11BE3A76]
n3:nazevZdroje
Jemná mechanika a optika
n3:obor
n18:BH
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
5
n3:rokUplatneniVysledku
n12:2013
n3:svazekPeriodika
58
n3:tvurceVysledku
Vlček, Jaroslav Lesňák, Michal Pištora, Jaromír Otipka, Petr Sobota, Jaroslav
s:issn
0447-6441
s:numberOfPages
5
n16:organizacniJednotka
27360