This HTML5 document contains 46 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n6http://localhost/temp/predkladatel/
n16http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n11http://linked.opendata.cz/resource/domain/vavai/projekt/
n15http://linked.opendata.cz/ontology/domain/vavai/
n4http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F61989100%3A27360%2F08%3A00019437%21RIV10-MSM-27360___/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n5http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n17http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n18http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F61989100%3A27360%2F08%3A00019437%21RIV10-MSM-27360___
rdf:type
n15:Vysledek skos:Concept
dcterms:description
Komprimovaný zemní plyn na kompresorové stanici K01 ve Velkých Kapušanech se ochlazuje různými typy chladičů. Jejich tepelný výkon ovlivňuje čistota teplosměnné plochy na vnitřní i vnější straně. Při běžném provozu chladičů se na obou stranách teplosměnné plochy usazuje nános, který snižuje chladicí účinek. V článku je uveden postup výpočtu tepelného výkonu chladiče dvěma metodami. Jedná se o bilanční metodu a metodu vycházející z jednotlivých rovnic transportu tepla mezi zemním plynem a chladicím vzduchem. Výpočet byl uskutečněn pro čistou teplosměnnou plochu a plochu zanesenou na vnější straně nánosem prachu tloušťky 0,9 mm a na vnitřní straně nánosem o tloušťce od 0 do 7 mm. Komprimovaný zemní plyn na kompresorové stanici K01 ve Velkých Kapušanech se ochlazuje různými typy chladičů. Jejich tepelný výkon ovlivňuje čistota teplosměnné plochy na vnitřní i vnější straně. Při běžném provozu chladičů se na obou stranách teplosměnné plochy usazuje nános, který snižuje chladicí účinek. V článku je uveden postup výpočtu tepelného výkonu chladiče dvěma metodami. Jedná se o bilanční metodu a metodu vycházející z jednotlivých rovnic transportu tepla mezi zemním plynem a chladicím vzduchem. Výpočet byl uskutečněn pro čistou teplosměnnou plochu a plochu zanesenou na vnější straně nánosem prachu tloušťky 0,9 mm a na vnitřní straně nánosem o tloušťce od 0 do 7 mm. Compressed natural gas at KS01 Compressor Station in Velke Kapušany is currently cooled down by various cooler types. Their thermal output is influenced by the purity of the thermal exchange internal & external surfaces. By a normal operation of these coolers the dirt-sediment is encrusted on top of both sides of the heat-exchange area thus reducing the cooling effect. The article presents a cooler thermal output calculation procedure by two methods. The first one is a balance method, the second one is based on the formulas applied for the heat transfer between natural gas and cooling air. The calculation is made for the clean heat-exchange area and for the dust-clogged area with the thickness of dirt layer being 0,9 mm on the external side and 0 to 7 mm on the internal side.
dcterms:title
Thermal Capacity of a Natural Gas Cooler with a Clean and a Clogged Heat Exchanging Area Tepelný výkon chladiča zemného plynu s čistou a zanesenou teplovýmennou plochou Tepelný výkon chladiča zemného plynu s čistou a zanesenou teplovýmennou plochou
skos:prefLabel
Tepelný výkon chladiča zemného plynu s čistou a zanesenou teplovýmennou plochou Thermal Capacity of a Natural Gas Cooler with a Clean and a Clogged Heat Exchanging Area Tepelný výkon chladiča zemného plynu s čistou a zanesenou teplovýmennou plochou
skos:notation
RIV/61989100:27360/08:00019437!RIV10-MSM-27360___
n3:aktivita
n10:P n10:N
n3:aktivity
N, P(GA106/07/0938)
n3:cisloPeriodika
3
n3:dodaniDat
n18:2010
n3:domaciTvurceVysledku
n16:4157524 n16:2217112
n3:druhVysledku
n12:J
n3:duvernostUdaju
n14:S
n3:entitaPredkladatele
n4:predkladatel
n3:idSjednocenehoVysledku
399547
n3:idVysledku
RIV/61989100:27360/08:00019437
n3:jazykVysledku
n17:cze
n3:klicovaSlova
natural gas cooler; thermal output; sediment; balance method; heat transfer
n3:klicoveSlovo
n5:thermal%20output n5:heat%20transfer n5:balance%20method n5:natural%20gas%20cooler n5:sediment
n3:kodStatuVydavatele
SK - Slovenská republika
n3:kontrolniKodProRIV
[1C8B4472A6D3]
n3:nazevZdroje
Slovgas
n3:obor
n7:JG
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
3
n3:projekt
n11:GA106%2F07%2F0938
n3:rokUplatneniVysledku
n18:2008
n3:svazekPeriodika
17
n3:tvurceVysledku
Čarnogurská, Mária Příhoda, Miroslav Molínek, Jiří
s:issn
1335-3853
s:numberOfPages
6
n6:organizacniJednotka
27360