This HTML5 document contains 44 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n16http://localhost/temp/predkladatel/
n9http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n15http://linked.opendata.cz/resource/domain/vavai/subjekt/
n11http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
n6http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F61989100%3A27240%2F11%3A86081110%21RIV12-MSM-27240___/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n8http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n18http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n13http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n5http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F61989100%3A27240%2F11%3A86081110%21RIV12-MSM-27240___
rdf:type
skos:Concept n11:Vysledek
dcterms:description
The pacing for permanent pacing in bradyarrhytmias can influence entricular activation and can contribute to marked asynchrony in extremity. In this work, we search the optimal position for right ventricular pacing according the QRS duration. We evaluate the system for detection of QRS boundaries based on wavelet transform and adaptive threshold. The system is used during pacemaker implantations in Department of Cardiology, Heart Center, Hospital Podlesí Třinec. The pacing for permanent pacing in bradyarrhytmias can influence entricular activation and can contribute to marked asynchrony in extremity. In this work, we search the optimal position for right ventricular pacing according the QRS duration. We evaluate the system for detection of QRS boundaries based on wavelet transform and adaptive threshold. The system is used during pacemaker implantations in Department of Cardiology, Heart Center, Hospital Podlesí Třinec.
dcterms:title
Real time mapping QRS duration based on wavelets Real time mapping QRS duration based on wavelets
skos:prefLabel
Real time mapping QRS duration based on wavelets Real time mapping QRS duration based on wavelets
skos:notation
RIV/61989100:27240/11:86081110!RIV12-MSM-27240___
n11:predkladatel
n15:orjk%3A27240
n3:aktivita
n17:S
n3:aktivity
S
n3:cisloPeriodika
9A
n3:dodaniDat
n5:2012
n3:domaciTvurceVysledku
n9:1487604 n9:8196141 n9:7617437
n3:druhVysledku
n13:J
n3:duvernostUdaju
n12:S
n3:entitaPredkladatele
n6:predkladatel
n3:idSjednocenehoVysledku
225815
n3:idVysledku
RIV/61989100:27240/11:86081110
n3:jazykVysledku
n18:eng
n3:klicovaSlova
real, time, mapping, wavelet
n3:klicoveSlovo
n8:real n8:time n8:mapping n8:wavelet
n3:kodStatuVydavatele
PL - Polská republika
n3:kontrolniKodProRIV
[790013CC86FD]
n3:nazevZdroje
Przeglad elektrotechniczny
n3:obor
n7:JC
n3:pocetDomacichTvurcuVysledku
3
n3:pocetTvurcuVysledku
4
n3:rokUplatneniVysledku
n5:2011
n3:svazekPeriodika
87
n3:tvurceVysledku
Penhaker, Marek Srovnal, Vilém Jiravsky, Otakar Pindor, Jakub
n3:wos
000294289600067
s:issn
0033-2097
s:numberOfPages
4
n16:organizacniJednotka
27240