This HTML5 document contains 46 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n13http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n20http://localhost/temp/predkladatel/
n14http://purl.org/net/nknouf/ns/bibtex#
n11http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n17http://linked.opendata.cz/resource/domain/vavai/subjekt/
n16http://linked.opendata.cz/ontology/domain/vavai/
n21http://linked.opendata.cz/resource/domain/vavai/zamer/
n8https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n22http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F61989100%3A27240%2F11%3A86079259%21RIV12-MSM-27240___/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n12http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n5http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F61989100%3A27240%2F11%3A86079259%21RIV12-MSM-27240___
rdf:type
n16:Vysledek skos:Concept
dcterms:description
In the power company CEZ in the North Moravia Re-gion (the Czech Republic) the monitoring of a number of selected parameters of the quality of electrical energy (har-monics, flicker and unbalance) is being carried out in coop-eration with research laboratories of the Faculty of Electrical Engineering and Computer Science, VSB - Tech-nical University of Ostrava. The monitoring is being carried out in a complex manner in 59 feeding points 400 V, always within one week intervals, and at the same time on all voltage levels (HV, MV and LV). In the paper, the results of the complex monitoring during 12 years will be summarized together with the comparison of the changes of parameters after three years. In addition the results of annual continual monitoring for one selected locality on MV level will be presented in the paper. This article also compares the 95% and 99% of the collected values of the parameters. of power quality. In the power company CEZ in the North Moravia Re-gion (the Czech Republic) the monitoring of a number of selected parameters of the quality of electrical energy (har-monics, flicker and unbalance) is being carried out in coop-eration with research laboratories of the Faculty of Electrical Engineering and Computer Science, VSB - Tech-nical University of Ostrava. The monitoring is being carried out in a complex manner in 59 feeding points 400 V, always within one week intervals, and at the same time on all voltage levels (HV, MV and LV). In the paper, the results of the complex monitoring during 12 years will be summarized together with the comparison of the changes of parameters after three years. In addition the results of annual continual monitoring for one selected locality on MV level will be presented in the paper. This article also compares the 95% and 99% of the collected values of the parameters. of power quality.
dcterms:title
Evaluation of Selected Parameters of Quality of Electric Energy Distribution Network Evaluation of Selected Parameters of Quality of Electric Energy Distribution Network
skos:prefLabel
Evaluation of Selected Parameters of Quality of Electric Energy Distribution Network Evaluation of Selected Parameters of Quality of Electric Energy Distribution Network
skos:notation
RIV/61989100:27240/11:86079259!RIV12-MSM-27240___
n16:predkladatel
n17:orjk%3A27240
n3:aktivita
n12:S n12:Z
n3:aktivity
S, Z(MSM6198910007)
n3:dodaniDat
n5:2012
n3:domaciTvurceVysledku
n11:6554059 n11:9973605 n11:2620537
n3:druhVysledku
n10:D
n3:duvernostUdaju
n19:S
n3:entitaPredkladatele
n22:predkladatel
n3:idSjednocenehoVysledku
198352
n3:idVysledku
RIV/61989100:27240/11:86079259
n3:jazykVysledku
n7:eng
n3:klicovaSlova
power quality, harmonics, flicker, unbalance
n3:klicoveSlovo
n4:flicker n4:harmonics n4:unbalance n4:power%20quality
n3:kontrolniKodProRIV
[6B7EE6E0D36E]
n3:mistoKonaniAkce
Kouty nad Desnou
n3:mistoVydani
Ostrava
n3:nazevZdroje
Proceedings of the 12th International Scientific Conference Electric Power Engineering 2011
n3:obor
n18:JA
n3:pocetDomacichTvurcuVysledku
3
n3:pocetTvurcuVysledku
3
n3:rokUplatneniVysledku
n5:2011
n3:tvurceVysledku
Krejčí, Petr Rozehnal, Petr Čumpelík, Radim
n3:typAkce
n13:WRD
n3:zahajeniAkce
2011-05-17+02:00
n3:zamer
n21:MSM6198910007
s:numberOfPages
4
n14:hasPublisher
Vysoká škola báňská - Technická univerzita Ostrava
n8:isbn
978-80-248-2393-5
n20:organizacniJednotka
27240