This HTML5 document contains 54 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n18http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n19http://localhost/temp/predkladatel/
n7http://purl.org/net/nknouf/ns/bibtex#
n10http://linked.opendata.cz/resource/domain/vavai/projekt/
n8http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n9http://linked.opendata.cz/ontology/domain/vavai/
n16https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n15http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F61989100%3A27240%2F10%3A86075726%21RIV11-MPO-27240___/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n21http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n11http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n17http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F61989100%3A27240%2F10%3A86075726%21RIV11-MPO-27240___
rdf:type
n9:Vysledek skos:Concept
dcterms:description
Ensuring that Uninterruptible Power Supplies (UPS) are designed and operating properly is essential to guarantee that the UPS will satisfactorily protect sensitive equipment against ac mains voltage abnormalities. Power surges, power sags, power swells, missing line cycles, clipped sine waves, noise voltages, and frequency variations are just some of the abnormalities that can occur on the power network. The paper describes automated test system for testing UPS. Phase dependent transfer time and voltage transfer points are some of the measurements that can be made. Ensuring that Uninterruptible Power Supplies (UPS) are designed and operating properly is essential to guarantee that the UPS will satisfactorily protect sensitive equipment against ac mains voltage abnormalities. Power surges, power sags, power swells, missing line cycles, clipped sine waves, noise voltages, and frequency variations are just some of the abnormalities that can occur on the power network. The paper describes automated test system for testing UPS. Phase dependent transfer time and voltage transfer points are some of the measurements that can be made.
dcterms:title
Testing of Uninterruptable Power Supplies (UPS) Response on Short Time Voltage Dips, Swells and Interruptions Testing of Uninterruptable Power Supplies (UPS) Response on Short Time Voltage Dips, Swells and Interruptions
skos:prefLabel
Testing of Uninterruptable Power Supplies (UPS) Response on Short Time Voltage Dips, Swells and Interruptions Testing of Uninterruptable Power Supplies (UPS) Response on Short Time Voltage Dips, Swells and Interruptions
skos:notation
RIV/61989100:27240/10:86075726!RIV11-MPO-27240___
n3:aktivita
n5:P
n3:aktivity
P(FR-TI1/223)
n3:dodaniDat
n17:2011
n3:domaciTvurceVysledku
n8:9573283 n8:1550365 n8:6006108
n3:druhVysledku
n12:D
n3:duvernostUdaju
n21:S
n3:entitaPredkladatele
n15:predkladatel
n3:idSjednocenehoVysledku
292483
n3:idVysledku
RIV/61989100:27240/10:86075726
n3:jazykVysledku
n11:eng
n3:klicovaSlova
Interruptions; and; Swells; Dips,; Voltage; Time; Short; Response; (UPS); Supplies; Power; Uninterruptable; Testing
n3:klicoveSlovo
n4:Supplies n4:Time n4:Testing n4:Dips n4:Uninterruptable n4:Short n4:%28UPS%29 n4:Power n4:and n4:Voltage n4:Response n4:Swells n4:Interruptions
n3:kontrolniKodProRIV
[2EA5514628C2]
n3:mistoKonaniAkce
Brno
n3:mistoVydani
Brno
n3:nazevZdroje
Proceedings of the 11th International Scienticic Conference Electric Power Engineering 2010
n3:obor
n6:JA
n3:pocetDomacichTvurcuVysledku
3
n3:pocetTvurcuVysledku
3
n3:projekt
n10:FR-TI1%2F223
n3:rokUplatneniVysledku
n17:2010
n3:tvurceVysledku
Bilík, Petr Hořínek, Marek Pětvaldský, Petr
n3:typAkce
n18:WRD
n3:wos
000284981100098
n3:zahajeniAkce
2010-05-04+02:00
s:numberOfPages
4
n7:hasPublisher
University of Technology
n16:isbn
978-80-214-4094-4
n19:organizacniJednotka
27240