This HTML5 document contains 44 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n8http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n19http://purl.org/net/nknouf/ns/bibtex#
n17http://localhost/temp/predkladatel/
n15http://linked.opendata.cz/resource/domain/vavai/projekt/
n10http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n14http://linked.opendata.cz/ontology/domain/vavai/
n20https://schema.org/
shttp://schema.org/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/
skoshttp://www.w3.org/2004/02/skos/core#
n16http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F61989100%3A27240%2F09%3A10228591%21RIV11-MPO-27240___/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n13http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n21http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n7http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F61989100%3A27240%2F09%3A10228591%21RIV11-MPO-27240___
rdf:type
n14:Vysledek skos:Concept
dcterms:description
The number of distributed energy sources (DER), the huge increase of loads with switching supplies and the massive use of compact saving lamps brings the need to measure and evaluate voltage and current up to 9kHz. Annex B of the latest update of the IEC 61000-4-7:2002/A1:2008 unifies the length of the basic time window for the evaluation of signal components up to 2kHz and for the evaluation of signal components in the range of 2kHz-9kHz. This fact, together with latest measurement technologies, allows the simultaneous evaluation of signal components in the entire range of 50Hz-9kHz, even for very small amplitudes of frequency components. This paper analyzes and describes the technical problems to be solved in order to meet the requirements of IEC 610004-7:2002/A1:2008. The paper presents the results of measurements performed on different loads with expected significant signal components in the frequency range of 2kHz-9kHz, such as PC power supply. The number of distributed energy sources (DER), the huge increase of loads with switching supplies and the massive use of compact saving lamps brings the need to measure and evaluate voltage and current up to 9kHz. Annex B of the latest update of the IEC 61000-4-7:2002/A1:2008 unifies the length of the basic time window for the evaluation of signal components up to 2kHz and for the evaluation of signal components in the range of 2kHz-9kHz. This fact, together with latest measurement technologies, allows the simultaneous evaluation of signal components in the entire range of 50Hz-9kHz, even for very small amplitudes of frequency components. This paper analyzes and describes the technical problems to be solved in order to meet the requirements of IEC 610004-7:2002/A1:2008. The paper presents the results of measurements performed on different loads with expected significant signal components in the frequency range of 2kHz-9kHz, such as PC power supply.
dcterms:title
Measurement of Voltage and Current Harmonics for Frequencies up to 9 kHz According to IEC61000-4-7 Measurement of Voltage and Current Harmonics for Frequencies up to 9 kHz According to IEC61000-4-7
skos:prefLabel
Measurement of Voltage and Current Harmonics for Frequencies up to 9 kHz According to IEC61000-4-7 Measurement of Voltage and Current Harmonics for Frequencies up to 9 kHz According to IEC61000-4-7
skos:notation
RIV/61989100:27240/09:10228591!RIV11-MPO-27240___
n5:aktivita
n21:P
n5:aktivity
P(FR-TI1/223)
n5:dodaniDat
n7:2011
n5:domaciTvurceVysledku
n10:6006108
n5:druhVysledku
n11:D
n5:duvernostUdaju
n18:S
n5:entitaPredkladatele
n16:predkladatel
n5:idSjednocenehoVysledku
325085
n5:idVysledku
RIV/61989100:27240/09:10228591
n5:jazykVysledku
n6:eng
n5:klicovaSlova
LabVIEW; distributed energy sources; power quality; IEC 61000-4-7:2002/A1:2008; harmonic components up to 9kHz; current harmonics up to 9kHz; voltage harmonics up to 9kHz
n5:klicoveSlovo
n13:IEC%2061000-4-7%3A2002%2FA1%3A2008 n13:harmonic%20components%20up%20to%209kHz n13:LabVIEW n13:power%20quality n13:voltage%20harmonics%20up%20to%209kHz n13:distributed%20energy%20sources n13:current%20harmonics%20up%20to%209kHz
n5:kontrolniKodProRIV
[5EDDDDC9AC9B]
n5:mistoKonaniAkce
Lodz, POLAND
n5:mistoVydani
NEW YORK
n5:nazevZdroje
2009 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL POWER QUALITY AND UTILISATION (EPQU 2009)
n5:obor
n12:JA
n5:pocetDomacichTvurcuVysledku
1
n5:pocetTvurcuVysledku
1
n5:projekt
n15:FR-TI1%2F223
n5:rokUplatneniVysledku
n7:2009
n5:tvurceVysledku
BilĂ­k, Petr
n5:typAkce
n8:WRD
n5:wos
000274778700034
n5:zahajeniAkce
2009-09-15+02:00
s:numberOfPages
5
n19:hasPublisher
IEEE, 345 E 47TH ST, NEW YORK, NY 10017 USA
n20:isbn
978-1-4244-5171-5
n17:organizacniJednotka
27240