This HTML5 document contains 44 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n20http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n14http://localhost/temp/predkladatel/
n12http://purl.org/net/nknouf/ns/bibtex#
n15http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n16http://linked.opendata.cz/ontology/domain/vavai/
n19https://schema.org/
n9http://linked.opendata.cz/resource/domain/vavai/zamer/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n17http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F61989100%3A27240%2F04%3A00010029%21RIV%2F2005%2FMSM%2F272405%2FN/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n5http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n21http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n13http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F61989100%3A27240%2F04%3A00010029%21RIV%2F2005%2FMSM%2F272405%2FN
rdf:type
skos:Concept n16:Vysledek
dcterms:description
This paper deals with the accuracy of evaluation of voltage and current parameters and circuit parameters in a measuring point of an electrical circuit. The parameters are determined from digitized voltage and current signals acquired by digital measuring instruments. The most important integral parameters of a alternating, periodic voltage and current waveform as their root mean square (rms), the apparent power, the active power, the reactive power and the basic (equivalent) circuit parameters as the resistance, the induc-tance and the capacitance are discussed. The influence of the digitization of distorted volt-age and current waveforms on the evaluation of the above mentioned parameters is verified by simulation for experimental measured voltage and current waveforms. This paper deals with the accuracy of evaluation of voltage and current parameters and circuit parameters in a measuring point of an electrical circuit. The parameters are determined from digitized voltage and current signals acquired by digital measuring instruments. The most important integral parameters of a alternating, periodic voltage and current waveform as their root mean square (rms), the apparent power, the active power, the reactive power and the basic (equivalent) circuit parameters as the resistance, the induc-tance and the capacitance are discussed. The influence of the digitization of distorted volt-age and current waveforms on the evaluation of the above mentioned parameters is verified by simulation for experimental measured voltage and current waveforms. This paper deals with the accuracy of evaluation of voltage and current parameters and circuit parameters in a measuring point of an electrical circuit. The parameters are determined from digitized voltage and current signals acquired by digital measuring instruments. The most important integral parameters of a alternating, periodic voltage and current waveform as their root mean square (rms), the apparent power, the active power, the reactive power and the basic (equivalent) circuit parameters as the resistance, the induc-tance and the capacitance are discussed. The influence of the digitization of distorted volt-age and current waveforms on the evaluation of the above mentioned parameters is verified by simulation for experimental measured voltage and current waveforms.
dcterms:title
Accuracy of evaluation of distorted voltage and current parameters Vyhodnocování přesnosti parametrů zkreslených průběhů napětí a proudu Vyhodnocování přesnosti parametrů zkreslených průběhů napětí a proudu
skos:prefLabel
Vyhodnocování přesnosti parametrů zkreslených průběhů napětí a proudu Accuracy of evaluation of distorted voltage and current parameters Vyhodnocování přesnosti parametrů zkreslených průběhů napětí a proudu
skos:notation
RIV/61989100:27240/04:00010029!RIV/2005/MSM/272405/N
n3:strany
145-148
n3:aktivita
n8:Z
n3:aktivity
Z(MSM 272400014)
n3:dodaniDat
n13:2005
n3:domaciTvurceVysledku
n15:7166222
n3:druhVysledku
n18:D
n3:duvernostUdaju
n10:S
n3:entitaPredkladatele
n17:predkladatel
n3:idSjednocenehoVysledku
593566
n3:idVysledku
RIV/61989100:27240/04:00010029
n3:jazykVysledku
n21:cze
n3:klicovaSlova
distortion;voltage;current;power
n3:klicoveSlovo
n5:distortion n5:voltage n5:current n5:power
n3:kontrolniKodProRIV
[94485BE675BE]
n3:mistoKonaniAkce
Tatranské Zruby
n3:mistoVydani
Liptovský Mikuláš
n3:nazevZdroje
Nové směry v spracovaní signálov VII.
n3:obor
n11:JA
n3:pocetDomacichTvurcuVysledku
1
n3:pocetTvurcuVysledku
1
n3:rokUplatneniVysledku
n13:2004
n3:tvurceVysledku
Orság, Petr
n3:typAkce
n20:EUR
n3:zahajeniAkce
2004-05-12+02:00
n3:zamer
n9:MSM%20272400014
s:numberOfPages
228
n12:hasPublisher
Vojenská akadémia SNP v Liptovskom Mikuláši
n19:isbn
80-8040-232-9
n14:organizacniJednotka
27240