This HTML5 document contains 42 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n6http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n21http://localhost/temp/predkladatel/
n9http://purl.org/net/nknouf/ns/bibtex#
n4http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n15http://linked.opendata.cz/resource/domain/vavai/subjekt/
n14http://linked.opendata.cz/ontology/domain/vavai/
n17https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n12http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F61989100%3A27120%2F13%3A86088989%21RIV14-MSM-27120___/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n19http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n13http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n20http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F61989100%3A27120%2F13%3A86088989%21RIV14-MSM-27120___
rdf:type
skos:Concept n14:Vysledek
dcterms:description
This paper deals with the possibilities of using coupled timber-concrete structures by means a glued coupling bar. The described process of static reinforcement is particularly suitable for reconstruction of historic timber ceilings and places where it is necessary to prevent damage to non-supporting structures (e.g. ceiling, plaster, stucco decorations, etc.). The method is also employed in those cases where it is necessary to allow traffic-flow in the rooms below the reconstructed ceiling. The article describes the specific technological process that has been examined in the reconstruction of the ceiling structure of a house on Sokolska Street in Ostrava. Following experimental testing in laboratories at the Faculty of Civil Engineering VSB - TU Ostrava the technology of bonded shear bars under static reinforcement of timber ceilings was first applied and successfully tested in construction practice. This paper deals with the possibilities of using coupled timber-concrete structures by means a glued coupling bar. The described process of static reinforcement is particularly suitable for reconstruction of historic timber ceilings and places where it is necessary to prevent damage to non-supporting structures (e.g. ceiling, plaster, stucco decorations, etc.). The method is also employed in those cases where it is necessary to allow traffic-flow in the rooms below the reconstructed ceiling. The article describes the specific technological process that has been examined in the reconstruction of the ceiling structure of a house on Sokolska Street in Ostrava. Following experimental testing in laboratories at the Faculty of Civil Engineering VSB - TU Ostrava the technology of bonded shear bars under static reinforcement of timber ceilings was first applied and successfully tested in construction practice.
dcterms:title
Coupled Timber–Concrete Ceiling using Coupled Timber–Concrete Ceiling using Bonded Shear Connectors Coupled Timber–Concrete Ceiling using Coupled Timber–Concrete Ceiling using Bonded Shear Connectors
skos:prefLabel
Coupled Timber–Concrete Ceiling using Coupled Timber–Concrete Ceiling using Bonded Shear Connectors Coupled Timber–Concrete Ceiling using Coupled Timber–Concrete Ceiling using Bonded Shear Connectors
skos:notation
RIV/61989100:27120/13:86088989!RIV14-MSM-27120___
n14:predkladatel
n15:orjk%3A27120
n3:aktivita
n19:V
n3:aktivity
V
n3:dodaniDat
n20:2014
n3:domaciTvurceVysledku
n4:9710795 n4:6128491
n3:druhVysledku
n8:D
n3:duvernostUdaju
n18:S
n3:entitaPredkladatele
n12:predkladatel
n3:idSjednocenehoVysledku
67214
n3:idVysledku
RIV/61989100:27120/13:86088989
n3:jazykVysledku
n7:eng
n3:klicovaSlova
Coupled and Composite Structures, Timber-Concrete Ceiling, Bonded Shear Connector
n3:klicoveSlovo
n10:Coupled%20and%20Composite%20Structures n10:Timber-Concrete%20Ceiling n10:Bonded%20Shear%20Connector
n3:kontrolniKodProRIV
[C2B4DB2A4108]
n3:mistoKonaniAkce
Singapur
n3:mistoVydani
Enfield, New Hampshire
n3:nazevZdroje
Advanced Materials Research. Volume 772
n3:obor
n13:JN
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
2
n3:rokUplatneniVysledku
n20:2013
n3:tvurceVysledku
Čajka, Radim Burkovič, Kamil
n3:typAkce
n6:WRD
n3:zahajeniAkce
2013-06-01+02:00
s:issn
1022-6680
s:numberOfPages
6
n9:hasPublisher
Trans Tech Publications
n17:isbn
978-3-03785-789-2
n21:organizacniJednotka
27120