This HTML5 document contains 48 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n8http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n20http://purl.org/net/nknouf/ns/bibtex#
n5http://localhost/temp/predkladatel/
n6http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n4http://linked.opendata.cz/resource/domain/vavai/projekt/
n12http://linked.opendata.cz/resource/domain/vavai/subjekt/
n11http://linked.opendata.cz/ontology/domain/vavai/
n18https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n7http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n19http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n21http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n22http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F61989100%3A27120%2F12%3A86083723%21RIV13-MSM-27120___/
n16http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F61989100%3A27120%2F12%3A86083723%21RIV13-MSM-27120___
rdf:type
skos:Concept n11:Vysledek
dcterms:description
The value of air permeability or the value of n50 provides important information about the impermeability of the building envelope and thus the quality of internal environment of the building. It is also one of the main evaluation criteria in classifying energy efficient buildings. Air permeability is determined by Blower Door Test where the fan blows air in or out from the measured area. The measurement is performed in a overpressure and afterwards in a underpressure during which the leaks are detected. The frame is usually placed into the front door which themselves is a link part in the building envelope and thus the rate of leakage completely denies. The effect of leakage of the front door is so significant that it can often cause a misclassification of the energy efficient buildings. We have tested this hypothesis by Blower Door Test on a passive timber construction build in 2007. The value of air permeability or the value of n50 provides important information about the impermeability of the building envelope and thus the quality of internal environment of the building. It is also one of the main evaluation criteria in classifying energy efficient buildings. Air permeability is determined by Blower Door Test where the fan blows air in or out from the measured area. The measurement is performed in a overpressure and afterwards in a underpressure during which the leaks are detected. The frame is usually placed into the front door which themselves is a link part in the building envelope and thus the rate of leakage completely denies. The effect of leakage of the front door is so significant that it can often cause a misclassification of the energy efficient buildings. We have tested this hypothesis by Blower Door Test on a passive timber construction build in 2007.
dcterms:title
The Importance of a Fan Location in the Front Door in Measuring of the Air Permeability by the Blower Door Test. The Importance of a Fan Location in the Front Door in Measuring of the Air Permeability by the Blower Door Test.
skos:prefLabel
The Importance of a Fan Location in the Front Door in Measuring of the Air Permeability by the Blower Door Test. The Importance of a Fan Location in the Front Door in Measuring of the Air Permeability by the Blower Door Test.
skos:notation
RIV/61989100:27120/12:86083723!RIV13-MSM-27120___
n11:predkladatel
n12:orjk%3A27120
n3:aktivita
n10:P
n3:aktivity
P(EE2.3.20.0013)
n3:dodaniDat
n16:2013
n3:domaciTvurceVysledku
n6:8794596 n6:8722870 n6:7593066 n6:1052624
n3:druhVysledku
n21:D
n3:duvernostUdaju
n14:S
n3:entitaPredkladatele
n22:predkladatel
n3:idSjednocenehoVysledku
140867
n3:idVysledku
RIV/61989100:27120/12:86083723
n3:jazykVysledku
n19:eng
n3:klicovaSlova
Air permeability, Blower Door Test, value of n50, internal environment, passive timber construction.
n3:klicoveSlovo
n7:Blower%20Door%20Test n7:internal%20environment n7:passive%20timber%20construction. n7:Air%20permeability n7:value%20of%20n50
n3:kontrolniKodProRIV
[0E9F461435D4]
n3:mistoKonaniAkce
Brno
n3:mistoVydani
Brno
n3:nazevZdroje
Buildings and Environment 2012 : digital proceedings : October 25th-26th 2012, Faculty of Civil Engineering, Brno University of Technology
n3:obor
n17:JN
n3:pocetDomacichTvurcuVysledku
4
n3:pocetTvurcuVysledku
4
n3:projekt
n4:EE2.3.20.0013
n3:rokUplatneniVysledku
n16:2012
n3:tvurceVysledku
Hrubá, Barbora Kučerová, Lucie Martiník, Lubomír Černíková, Marcela
n3:typAkce
n8:WRD
n3:zahajeniAkce
2012-10-25+02:00
s:numberOfPages
4
n20:hasPublisher
Vysoké učení technické v Brně
n18:isbn
978-80-214-4505-5
n5:organizacniJednotka
27120