This HTML5 document contains 38 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n11http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F61388998%3A_____%2F13%3A00391326%21RIV14-AV0-61388998/
dctermshttp://purl.org/dc/terms/
n6http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n10http://linked.opendata.cz/resource/domain/vavai/subjekt/
n9http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n5http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n14http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n7http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F61388998%3A_____%2F13%3A00391326%21RIV14-AV0-61388998
rdf:type
n9:Vysledek skos:Concept
dcterms:description
Current controlled voltage source converters are widely used in grid-connected applications, for example at ac drives with indirect frequency converters. The negative sequence component of the grid voltage causes ripples of the dc voltage in the intermediate circuit. Some sophisticated topologies of current controllers that can cope with grids containing both the positive and negative sequence components are summarized and compared for this purpose. A new dual current control algorithm was developed and tested in the Matlab/Simulink environment. Current controlled voltage source converters are widely used in grid-connected applications, for example at ac drives with indirect frequency converters. The negative sequence component of the grid voltage causes ripples of the dc voltage in the intermediate circuit. Some sophisticated topologies of current controllers that can cope with grids containing both the positive and negative sequence components are summarized and compared for this purpose. A new dual current control algorithm was developed and tested in the Matlab/Simulink environment.
dcterms:title
Control Strategy of PWM Rectifiers Connected to Unbalanced Grids Control Strategy of PWM Rectifiers Connected to Unbalanced Grids
skos:prefLabel
Control Strategy of PWM Rectifiers Connected to Unbalanced Grids Control Strategy of PWM Rectifiers Connected to Unbalanced Grids
skos:notation
RIV/61388998:_____/13:00391326!RIV14-AV0-61388998
n9:predkladatel
n10:ico%3A61388998
n4:aktivita
n8:I
n4:aktivity
I
n4:cisloPeriodika
11
n4:dodaniDat
n7:2014
n4:domaciTvurceVysledku
n6:9702849
n4:druhVysledku
n17:J
n4:duvernostUdaju
n16:S
n4:entitaPredkladatele
n11:predkladatel
n4:idSjednocenehoVysledku
66979
n4:idVysledku
RIV/61388998:_____/13:00391326
n4:jazykVysledku
n14:eng
n4:klicovaSlova
electric power system; PWM rectifier; dc voltage ripple
n4:klicoveSlovo
n5:electric%20power%20system n5:PWM%20rectifier n5:dc%20voltage%20ripple
n4:kodStatuVydavatele
ES - Španělské království
n4:kontrolniKodProRIV
[18965D25895D]
n4:nazevZdroje
Renewable Energy and Power Quality Journal
n4:obor
n15:JA
n4:pocetDomacichTvurcuVysledku
1
n4:pocetTvurcuVysledku
4
n4:rokUplatneniVysledku
n7:2013
n4:tvurceVysledku
Tlustý, J. Švec, J. Bejvl, Martin Valouch, V.
s:issn
2172-038X
s:numberOfPages
5