This HTML5 document contains 45 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n7http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n19http://linked.opendata.cz/resource/domain/vavai/subjekt/
n12http://linked.opendata.cz/ontology/domain/vavai/
n15http://linked.opendata.cz/resource/domain/vavai/zamer/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
rdfshttp://www.w3.org/2000/01/rdf-schema#
n5http://linked.opendata.cz/ontology/domain/vavai/riv/
n3http://bibframe.org/vocab/
n18http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F61388998%3A_____%2F12%3A00382230%21RIV13-AV0-61388998/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n11http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n20http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n14http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F61388998%3A_____%2F12%3A00382230%21RIV13-AV0-61388998
rdf:type
n12:Vysledek skos:Concept
rdfs:seeAlso
http://www.sciencedirect.com/science/article/pii/S001793101200470X
dcterms:description
Experimental identification of the residence time distribution (RTD) characteristics for steady (or pulsatile) flows using a stimulus response technique, for example using tracers, is very demanding. The accuracy of the RTD characteristics depends on the precise distribution of the injected tracer via the injection modulus, and also on appropriate design of the detector. The performance of various modifications of the injection modulus and of the conductivity probe is assessed using the simplest possible system – a straight pipe and fully developed laminar flow. This comparison is made via the deviation of the experimental values for the time of the first appearance and the mean residence time from the in theoretical values. We find the optimal configuration of the injection modulus and the conductivity probe for laminar and convection-dominated flow in a straight rigid pipe. Experimental identification of the residence time distribution (RTD) characteristics for steady (or pulsatile) flows using a stimulus response technique, for example using tracers, is very demanding. The accuracy of the RTD characteristics depends on the precise distribution of the injected tracer via the injection modulus, and also on appropriate design of the detector. The performance of various modifications of the injection modulus and of the conductivity probe is assessed using the simplest possible system – a straight pipe and fully developed laminar flow. This comparison is made via the deviation of the experimental values for the time of the first appearance and the mean residence time from the in theoretical values. We find the optimal configuration of the injection modulus and the conductivity probe for laminar and convection-dominated flow in a straight rigid pipe.
dcterms:title
Accuracy of tracer stimulus response experiments in laminar flows Accuracy of tracer stimulus response experiments in laminar flows
skos:prefLabel
Accuracy of tracer stimulus response experiments in laminar flows Accuracy of tracer stimulus response experiments in laminar flows
skos:notation
RIV/61388998:_____/12:00382230!RIV13-AV0-61388998
n12:predkladatel
n19:ico%3A61388998
n5:aktivita
n10:Z n10:S
n5:aktivity
S, Z(AV0Z20760514), Z(MSM6840770012)
n5:cisloPeriodika
23-24
n5:dodaniDat
n14:2013
n5:domaciTvurceVysledku
n7:3948137 n7:7146981
n5:druhVysledku
n17:J
n5:duvernostUdaju
n8:S
n5:entitaPredkladatele
n18:predkladatel
n5:idSjednocenehoVysledku
120877
n5:idVysledku
RIV/61388998:_____/12:00382230
n5:jazykVysledku
n20:eng
n5:klicovaSlova
residence time distribution; tracer injection; laminar convective dominated flow
n5:klicoveSlovo
n11:residence%20time%20distribution n11:tracer%20injection n11:laminar%20convective%20dominated%20flow
n5:kodStatuVydavatele
US - Spojené státy americké
n5:kontrolniKodProRIV
[898CF21352E4]
n5:nazevZdroje
International Journal of Heat and Mass Transfer
n5:obor
n9:JB
n5:pocetDomacichTvurcuVysledku
2
n5:pocetTvurcuVysledku
3
n5:rokUplatneniVysledku
n14:2012
n5:svazekPeriodika
55
n5:tvurceVysledku
Novotný, Pavel Chlup, Hynek Žitný, R.
n5:wos
000309042300016
n5:zamer
n15:AV0Z20760514 n15:MSM6840770012
s:issn
0017-9310
s:numberOfPages
5
n3:doi
10.1016/j.ijheatmasstransfer.2012.06.042