This HTML5 document contains 47 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n6http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n17http://linked.opendata.cz/resource/domain/vavai/subjekt/
n16http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n9http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F61383082%3A_____%2F11%3A0035%21RIV12-MO0-61383082/
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n5http://bibframe.org/vocab/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n13http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n15http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n4http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F61383082%3A_____%2F11%3A0035%21RIV12-MO0-61383082
rdf:type
skos:Concept n16:Vysledek
dcterms:description
The 3T ioMRI in Prague is composed of two independent suites: the operating theatre and the 3T MR suite, both of which can and do work independently. They are connected by a double door and a special transportation system. The whole operating table is moved on rails to and from the MR gantry. Anaesthesiological equipment is built from paramagnetic material, which is also moved to and from the MR suite. The integral parts of the multifunctional surgical suite (MFSS) are the neuronavigation system, electrophysiological monitoring, surgical microscope with availability of indocyanin green angiography and fluorescence-guided glioma resection technique and endoscopy equipment. The operating theatre is equipped in a normal fashion with the exception of a head holder that is paramagnetic. MR radiologist and MR assistants are alerted approximately 30 min before the requested intraoperative and out-patient service is interrupted to clean the MR suite. The ioMRI takes 15-20 min and immediately after the door closes the out patient activity is resumed. Intraoperative MR was performed in 332 surgeries in the first 17 months of operation. The most frequent indications were pituitary adenomas, followed by gliomas. Other indications were less frequent and included meningiomas, cavernomas, aneurysms, epilepsy surgery, intramedullary lesions, non-pituitary sellar lesions, metastases and various other surgeries. In 332 cases no technical or medical complication connected with ioMRI was encountered. The 3T ioMRI in Prague is composed of two independent suites: the operating theatre and the 3T MR suite, both of which can and do work independently. They are connected by a double door and a special transportation system. The whole operating table is moved on rails to and from the MR gantry. Anaesthesiological equipment is built from paramagnetic material, which is also moved to and from the MR suite. The integral parts of the multifunctional surgical suite (MFSS) are the neuronavigation system, electrophysiological monitoring, surgical microscope with availability of indocyanin green angiography and fluorescence-guided glioma resection technique and endoscopy equipment. The operating theatre is equipped in a normal fashion with the exception of a head holder that is paramagnetic. MR radiologist and MR assistants are alerted approximately 30 min before the requested intraoperative and out-patient service is interrupted to clean the MR suite. The ioMRI takes 15-20 min and immediately after the door closes the out patient activity is resumed. Intraoperative MR was performed in 332 surgeries in the first 17 months of operation. The most frequent indications were pituitary adenomas, followed by gliomas. Other indications were less frequent and included meningiomas, cavernomas, aneurysms, epilepsy surgery, intramedullary lesions, non-pituitary sellar lesions, metastases and various other surgeries. In 332 cases no technical or medical complication connected with ioMRI was encountered.
dcterms:title
Multifunctional surgical suite (MFSS) with 3.0 T iMRI: 17 months of experience Multifunctional surgical suite (MFSS) with 3.0 T iMRI: 17 months of experience
skos:prefLabel
Multifunctional surgical suite (MFSS) with 3.0 T iMRI: 17 months of experience Multifunctional surgical suite (MFSS) with 3.0 T iMRI: 17 months of experience
skos:notation
RIV/61383082:_____/11:0035!RIV12-MO0-61383082
n16:predkladatel
n17:ico%3A61383082
n3:aktivita
n10:V
n3:aktivity
V
n3:cisloPeriodika
4
n3:dodaniDat
n4:2012
n3:domaciTvurceVysledku
n6:8725705 n6:7793294 n6:2500027 n6:3588254 n6:1692267
n3:druhVysledku
n18:J
n3:duvernostUdaju
n11:S
n3:entitaPredkladatele
n9:predkladatel
n3:idSjednocenehoVysledku
214227
n3:idVysledku
RIV/61383082:_____/11:0035
n3:jazykVysledku
n15:eng
n3:klicovaSlova
Glioma; Intraoperative imaging; Magnetic resonance; Neuronavigation; Pituitary adenoma
n3:klicoveSlovo
n13:Pituitary%20adenoma n13:Glioma n13:Magnetic%20resonance n13:Neuronavigation n13:Intraoperative%20imaging
n3:kodStatuVydavatele
AT - Rakouská republika
n3:kontrolniKodProRIV
[98DD969462C9]
n3:nazevZdroje
Acta Neurochir Suppl. 2011
n3:obor
n12:FH
n3:pocetDomacichTvurcuVysledku
5
n3:pocetTvurcuVysledku
5
n3:rokUplatneniVysledku
n4:2011
n3:svazekPeriodika
109
n3:tvurceVysledku
Ostrý, Svatopluk Belšán, Tomáš Kramář, Filip Beneš, Vladimír Netuka, David
s:issn
0001-6268
s:numberOfPages
5
n5:doi
10.1007/978-3-211-99651-5_22