This HTML5 document contains 46 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n21http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n23http://purl.org/net/nknouf/ns/bibtex#
n18http://localhost/temp/predkladatel/
n9http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n13http://linked.opendata.cz/resource/domain/vavai/subjekt/
n12http://linked.opendata.cz/ontology/domain/vavai/
n7http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F60461373%3A22340%2F13%3A43895117%21RIV14-MSM-22340___/
n8https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
rdfshttp://www.w3.org/2000/01/rdf-schema#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n17http://bibframe.org/vocab/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n22http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n20http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n19http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F60461373%3A22340%2F13%3A43895117%21RIV14-MSM-22340___
rdf:type
skos:Concept n12:Vysledek
rdfs:seeAlso
http://proceedings.aip.org/resource/2/apcpcs/1552/1/498_1
dcterms:description
In the calibration laboratories are used standard procedures for calculating of the calibration model coefficients based on well described standards (EN 60751, ITS-90, EN 60584, etc.). In practice, sensors are mostly calibrated in more points and redundant information is used as a validation of the model. This paper will present the influence of including all measured points with respect to their uncertainties to the measured models using standard weighted least square methods. A special case with regards of the different level of the uncertainty of the measured points in case of the robust approach will be discussed. This will go to the different minimization criteria and different uncertainty propagation methodology. This approach also will eliminate of the influence of the outline measurements in the calibration. In practical part will be three cases of this approach presented, namely industrial calibration according to the standard EN 60751, SPRT according to the ITS-90 and thermocouple according to the standard EN 60584. In the calibration laboratories are used standard procedures for calculating of the calibration model coefficients based on well described standards (EN 60751, ITS-90, EN 60584, etc.). In practice, sensors are mostly calibrated in more points and redundant information is used as a validation of the model. This paper will present the influence of including all measured points with respect to their uncertainties to the measured models using standard weighted least square methods. A special case with regards of the different level of the uncertainty of the measured points in case of the robust approach will be discussed. This will go to the different minimization criteria and different uncertainty propagation methodology. This approach also will eliminate of the influence of the outline measurements in the calibration. In practical part will be three cases of this approach presented, namely industrial calibration according to the standard EN 60751, SPRT according to the ITS-90 and thermocouple according to the standard EN 60584.
dcterms:title
A robust approach to using of the redundant information in the temperature calibration A robust approach to using of the redundant information in the temperature calibration
skos:prefLabel
A robust approach to using of the redundant information in the temperature calibration A robust approach to using of the redundant information in the temperature calibration
skos:notation
RIV/60461373:22340/13:43895117!RIV14-MSM-22340___
n12:predkladatel
n13:orjk%3A22340
n3:aktivita
n20:V
n3:aktivity
V
n3:dodaniDat
n19:2014
n3:domaciTvurceVysledku
n9:5905400 n9:2685337
n3:druhVysledku
n11:D
n3:duvernostUdaju
n22:S
n3:entitaPredkladatele
n7:predkladatel
n3:idSjednocenehoVysledku
59030
n3:idVysledku
RIV/60461373:22340/13:43895117
n3:jazykVysledku
n6:eng
n3:klicovaSlova
calibration model; uncertainty; robust method
n3:klicoveSlovo
n4:uncertainty n4:robust%20method n4:calibration%20model
n3:kontrolniKodProRIV
[44BF62883EFD]
n3:mistoKonaniAkce
Los Angeles, California
n3:mistoVydani
Melville
n3:nazevZdroje
AIP Conference Proceedings
n3:obor
n10:JD
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
4
n3:rokUplatneniVysledku
n19:2013
n3:tvurceVysledku
Šindelář, Martin Strnad, Radek Kňazovická, Lenka Kukal, Jaromír
n3:typAkce
n21:WRD
n3:zahajeniAkce
2012-03-19+01:00
s:issn
0094-243X
s:numberOfPages
6
n17:doi
10.1063/1.4819591
n23:hasPublisher
American Institute of Physics
n8:isbn
978-0-7354-1178-4
n18:organizacniJednotka
22340