This HTML5 document contains 45 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n9http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F60460709%3A41310%2F11%3A50621%21RIV12-MSM-41310___/
dctermshttp://purl.org/dc/terms/
n17http://localhost/temp/predkladatel/
n13http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n16http://linked.opendata.cz/resource/domain/vavai/subjekt/
n11http://linked.opendata.cz/ontology/domain/vavai/
n19http://linked.opendata.cz/resource/domain/vavai/zamer/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n10http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n15http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n6http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F60460709%3A41310%2F11%3A50621%21RIV12-MSM-41310___
rdf:type
skos:Concept n11:Vysledek
dcterms:description
The paper contains short description of a special device developed for study of electrical after-effect in vegetable cellular tissues after short electric pulses applied to the tissue. The device contains generator of the pulses and the microprocessor controlling circuits for time arrangement of the pulse amplification and collection of data for further evaluation. The pulses are based on AC signal with frequency 10-100 kHz with the amplified voltage up to ±240V and duration 1-10 ms. After finishing the individual pulse, the AC source signal continue, but amplitude on the tissue is 21.5times lower. The data about AC voltage and current intensity are continuously collected with frequency 800 kHz and then fed to PC USB input that was used to calculate time chart of electric properties of the tissue, its complex permittivity and specific complex conductivity. An example of the obtained results on potato tissue is given. The paper contains short description of a special device developed for study of electrical after-effect in vegetable cellular tissues after short electric pulses applied to the tissue. The device contains generator of the pulses and the microprocessor controlling circuits for time arrangement of the pulse amplification and collection of data for further evaluation. The pulses are based on AC signal with frequency 10-100 kHz with the amplified voltage up to ±240V and duration 1-10 ms. After finishing the individual pulse, the AC source signal continue, but amplitude on the tissue is 21.5times lower. The data about AC voltage and current intensity are continuously collected with frequency 800 kHz and then fed to PC USB input that was used to calculate time chart of electric properties of the tissue, its complex permittivity and specific complex conductivity. An example of the obtained results on potato tissue is given.
dcterms:title
Device for study of electric pulse after-effect in vegetable tissue Device for study of electric pulse after-effect in vegetable tissue
skos:prefLabel
Device for study of electric pulse after-effect in vegetable tissue Device for study of electric pulse after-effect in vegetable tissue
skos:notation
RIV/60460709:41310/11:50621!RIV12-MSM-41310___
n11:predkladatel
n16:orjk%3A41310
n4:aktivita
n15:Z
n4:aktivity
Z(MSM6046070905)
n4:cisloPeriodika
2
n4:dodaniDat
n6:2012
n4:domaciTvurceVysledku
n13:1348736 Yurov, Alexander
n4:druhVysledku
n18:J
n4:duvernostUdaju
n14:S
n4:entitaPredkladatele
n9:predkladatel
n4:idSjednocenehoVysledku
194151
n4:idVysledku
RIV/60460709:41310/11:50621
n4:jazykVysledku
n7:eng
n4:klicovaSlova
electric pulse, permittivity, cell wall, excitation, temperature, attenuation
n4:klicoveSlovo
n10:cell%20wall n10:electric%20pulse n10:attenuation n10:temperature n10:permittivity n10:excitation
n4:kodStatuVydavatele
CZ - Česká republika
n4:kontrolniKodProRIV
[6E0493E04799]
n4:nazevZdroje
Jemná mechanika a optika
n4:obor
n12:GM
n4:pocetDomacichTvurcuVysledku
2
n4:pocetTvurcuVysledku
3
n4:rokUplatneniVysledku
n6:2011
n4:svazekPeriodika
56
n4:tvurceVysledku
Šmejkal, Emanuel Yurov, Alexander Blahovec, Jiří
n4:wos
0
n4:zamer
n19:MSM6046070905
s:issn
0447-6441
s:numberOfPages
3
n17:organizacniJednotka
41310