This HTML5 document contains 41 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n14http://localhost/temp/predkladatel/
n6http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n5http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n9http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n8http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F60076658%3A12410%2F08%3A00010617%21RIV10-MSM-12410___/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n17http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n13http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F60076658%3A12410%2F08%3A00010617%21RIV10-MSM-12410___
rdf:type
n5:Vysledek skos:Concept
dcterms:description
Information regarding two versions of an instrument called a muscle dynamometer, which enables detailed information about muscle activity in the deep stabilisation spinal system (DSSS), presented in this article. The MD01 (muscle dynamometer ver.01) is a simple electromechanical instrument that allows measurement of muscle activity in two areas of the lumbar spine region. Measurements on patients have confirmed the usefulness of quantifying the initial state of a patient before rehabilitation as well as monitoring rehabilitation treatment; the MD01 is a suitable device for obtaining these measurements. However, a new and improved version of the MD01, the MD02, has been developed. The MD02 allows measurements in four different body regions and now has a PC interface, which allows achieving of patient information and data export for use with statistical software. Information regarding two versions of an instrument called a muscle dynamometer, which enables detailed information about muscle activity in the deep stabilisation spinal system (DSSS), presented in this article. The MD01 (muscle dynamometer ver.01) is a simple electromechanical instrument that allows measurement of muscle activity in two areas of the lumbar spine region. Measurements on patients have confirmed the usefulness of quantifying the initial state of a patient before rehabilitation as well as monitoring rehabilitation treatment; the MD01 is a suitable device for obtaining these measurements. However, a new and improved version of the MD01, the MD02, has been developed. The MD02 allows measurements in four different body regions and now has a PC interface, which allows achieving of patient information and data export for use with statistical software.
dcterms:title
Technical means for objectification of medical treatments in the area of the deep stabilisation spinal system Technical means for objectification of medical treatments in the area of the deep stabilisation spinal system
skos:prefLabel
Technical means for objectification of medical treatments in the area of the deep stabilisation spinal system Technical means for objectification of medical treatments in the area of the deep stabilisation spinal system
skos:notation
RIV/60076658:12410/08:00010617!RIV10-MSM-12410___
n3:aktivita
n11:V
n3:aktivity
V
n3:cisloPeriodika
1
n3:dodaniDat
n13:2010
n3:domaciTvurceVysledku
n6:6250661
n3:druhVysledku
n12:J
n3:duvernostUdaju
n10:S
n3:entitaPredkladatele
n8:predkladatel
n3:idSjednocenehoVysledku
399121
n3:idVysledku
RIV/60076658:12410/08:00010617
n3:jazykVysledku
n17:eng
n3:klicovaSlova
muscle dynamometer; muscular activity; deep stabilisation spinal system; spinal stabilisation
n3:klicoveSlovo
n9:spinal%20stabilisation n9:muscle%20dynamometer n9:deep%20stabilisation%20spinal%20system n9:muscular%20activity
n3:kodStatuVydavatele
SE - Švédské království
n3:kontrolniKodProRIV
[EB6951F8B67D]
n3:nazevZdroje
Neuroendocrinology Letters
n3:obor
n15:FB
n3:pocetDomacichTvurcuVysledku
1
n3:pocetTvurcuVysledku
4
n3:rokUplatneniVysledku
n13:2008
n3:svazekPeriodika
29
n3:tvurceVysledku
Kolář, Pavel Pučelík, Jiří Rokytová, Jitka Malátová, Renata
n3:wos
000254164800025
s:issn
0172-780X
s:numberOfPages
184
n14:organizacniJednotka
12410