This HTML5 document contains 46 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n21http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n20http://purl.org/net/nknouf/ns/bibtex#
n9http://localhost/temp/predkladatel/
n15http://linked.opendata.cz/resource/domain/vavai/projekt/
n6http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n13http://linked.opendata.cz/resource/domain/vavai/subjekt/
n12http://linked.opendata.cz/ontology/domain/vavai/
n17https://schema.org/
shttp://schema.org/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
skoshttp://www.w3.org/2004/02/skos/core#
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n19http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F49777513%3A23640%2F11%3A43897223%21RIV12-MSM-23640___/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n22http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n10http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n7http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F49777513%3A23640%2F11%3A43897223%21RIV12-MSM-23640___
rdf:type
n12:Vysledek skos:Concept
dcterms:description
New Technologies Research Centre at the University of West Bohemia in Pilsen uses middle-sized wind tunnel experimental facility. The tunnel equipment is extended in order to let us measure also heat transfer: the main wind tunnel duct itself forms the opened cooling air circuit, one closed circuit is there for water based coolang flow and one more closed circuit forms the hot compressed air loop. In this article, the typical measurement ot the thermal characteristics of the common water-air heat exchanger is presented. New Technologies Research Centre at the University of West Bohemia in Pilsen uses middle-sized wind tunnel experimental facility. The tunnel equipment is extended in order to let us measure also heat transfer: the main wind tunnel duct itself forms the opened cooling air circuit, one closed circuit is there for water based coolang flow and one more closed circuit forms the hot compressed air loop. In this article, the typical measurement ot the thermal characteristics of the common water-air heat exchanger is presented.
dcterms:title
Measuring thermal characteristics of the heat exchanger Measuring thermal characteristics of the heat exchanger
skos:prefLabel
Measuring thermal characteristics of the heat exchanger Measuring thermal characteristics of the heat exchanger
skos:notation
RIV/49777513:23640/11:43897223!RIV12-MSM-23640___
n12:predkladatel
n13:orjk%3A23640
n4:aktivita
n5:P n5:S
n4:aktivity
P(ED2.1.00/03.0088), S
n4:dodaniDat
n7:2012
n4:domaciTvurceVysledku
n6:3417921 n6:5838703 n6:2605813
n4:druhVysledku
n18:D
n4:duvernostUdaju
n22:S
n4:entitaPredkladatele
n19:predkladatel
n4:idSjednocenehoVysledku
211214
n4:idVysledku
RIV/49777513:23640/11:43897223
n4:jazykVysledku
n10:eng
n4:klicovaSlova
heat transfer, calorimetric tunnel, heat exchanger, energy balance
n4:klicoveSlovo
n11:heat%20exchanger n11:heat%20transfer n11:energy%20balance n11:calorimetric%20tunnel
n4:kontrolniKodProRIV
[4C63F7D0597D]
n4:mistoKonaniAkce
Jičín
n4:mistoVydani
Liberec
n4:nazevZdroje
Experimental Fluid Mechanics 2011
n4:obor
n16:BK
n4:pocetDomacichTvurcuVysledku
3
n4:pocetTvurcuVysledku
3
n4:projekt
n15:ED2.1.00%2F03.0088
n4:rokUplatneniVysledku
n7:2011
n4:tvurceVysledku
Kůs, Michal Syka, Tomáš Kňourek, Jindřich
n4:typAkce
n21:WRD
n4:zahajeniAkce
2011-11-22+01:00
s:numberOfPages
4
n20:hasPublisher
Technická univerzita
n17:isbn
978-80-7372-784-0
n9:organizacniJednotka
23640