This HTML5 document contains 44 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n12http://localhost/temp/predkladatel/
n13http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n3http://linked.opendata.cz/ontology/domain/vavai/
n9http://linked.opendata.cz/resource/domain/vavai/zamer/
n17http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F49777513%3A23640%2F07%3A00000010%21RIV08-MSM-23640___/
shttp://schema.org/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/
skoshttp://www.w3.org/2004/02/skos/core#
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n8http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n14http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n7http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F49777513%3A23640%2F07%3A00000010%21RIV08-MSM-23640___
rdf:type
n3:Vysledek skos:Concept
dcterms:description
Thermal box-barriers (TBB) are used for the thermal protection of measuring systems during exposure in a high temperature environment of various furnaces. This paper deals with problems of TBB design. TBB characteristics and limitations are discussed. The fourlayer TBB structure is proposed for the high temperature application. The computer simulation results are presented to show the typical time evolution and spatial distribution of temperature in TBB. Problems of optimum proposal of individual layers thickness are mentioned. Temperatures in the manufactured TBB measured by thermocouples during tests and applications in industrial reheating furnaces are introduced in order to verify the computational results and to show its real thermal insulation capabilities. Tepelná box-bariéra (TBB) je používána pro ochranu měřicích systémů před působením vysokých teplot v různých pecích. Článek se zabývá designem TBB. Jsou diskutovány charakteristiky a omezeni TBB. Je navržena čtyř-vrstvá TBB struktura pro vysokoteplotní aplikace. Výsledky počítačové simulace ukazují typické časové a prostorové rozložení teplot v TBB. Je zmíněn problém optimálního návrhu tloušťky vrstev TBB. Na vyrobené TBB jsou ukázány výsledky termočlánkového měření při testování a použití průmyslové ohřívací peci, které ověřují počítačovou simulaci a skutečné možnosti TBB. Thermal box-barriers (TBB) are used for the thermal protection of measuring systems during exposure in a high temperature environment of various furnaces. This paper deals with problems of TBB design. TBB characteristics and limitations are discussed. The fourlayer TBB structure is proposed for the high temperature application. The computer simulation results are presented to show the typical time evolution and spatial distribution of temperature in TBB. Problems of optimum proposal of individual layers thickness are mentioned. Temperatures in the manufactured TBB measured by thermocouples during tests and applications in industrial reheating furnaces are introduced in order to verify the computational results and to show its real thermal insulation capabilities.
dcterms:title
Tepelná bariéra pro přímé měření v prostředí vysokých teplot Thermal box-barrier for a direct measurement in high temperature environment Thermal box-barrier for a direct measurement in high temperature environment
skos:prefLabel
Thermal box-barrier for a direct measurement in high temperature environment Tepelná bariéra pro přímé měření v prostředí vysokých teplot Thermal box-barrier for a direct measurement in high temperature environment
skos:notation
RIV/49777513:23640/07:00000010!RIV08-MSM-23640___
n6:strany
560
n6:aktivita
n14:Z
n6:aktivity
Z(MSM4977751302)
n6:cisloPeriodika
0
n6:dodaniDat
n7:2008
n6:domaciTvurceVysledku
n13:5423724 n13:6877389
n6:druhVysledku
n10:J
n6:duvernostUdaju
n16:S
n6:entitaPredkladatele
n17:predkladatel
n6:idSjednocenehoVysledku
455026
n6:idVysledku
RIV/49777513:23640/07:00000010
n6:jazykVysledku
n11:eng
n6:klicovaSlova
Thermal barriers; Continuous furnaces; Temperature measurement; Computer simulation; Heat transfer
n6:klicoveSlovo
n8:Temperature%20measurement n8:Computer%20simulation n8:Thermal%20barriers n8:Continuous%20furnaces n8:Heat%20transfer
n6:kodStatuVydavatele
GB - Spojené království Velké Británie a Severního Irska
n6:kontrolniKodProRIV
[5172D2519E9A]
n6:nazevZdroje
Applied Thermal Engineering
n6:obor
n18:JB
n6:pocetDomacichTvurcuVysledku
2
n6:pocetTvurcuVysledku
2
n6:rokUplatneniVysledku
n7:2007
n6:tvurceVysledku
Honner, Milan Švantner, Michal
n6:zamer
n9:MSM4977751302
s:issn
1359-4311
s:numberOfPages
8
n12:organizacniJednotka
23640