This HTML5 document contains 50 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n21http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n7http://purl.org/net/nknouf/ns/bibtex#
n5http://localhost/temp/predkladatel/
n9http://linked.opendata.cz/resource/domain/vavai/projekt/
n4http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n16http://linked.opendata.cz/ontology/domain/vavai/
n18https://schema.org/
n6http://linked.opendata.cz/resource/domain/vavai/zamer/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n11http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n20http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n22http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n19http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F49777513%3A23520%2F07%3A00000157%21RIV08-MSM-23520___/
n8http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F49777513%3A23520%2F07%3A00000157%21RIV08-MSM-23520___
rdf:type
skos:Concept n16:Vysledek
dcterms:description
We identified the elasticity modulus for both living (34 kPa) and formalin-fixed samples (440 kPa). The ultimate strength was 0.10 MPa in living samples and (0.46 MPa) in formalin-fixed samples. The microcracks ran preferentially through the collagen connective tissue far from the SMC rather than through the connective tissue surrounding the SMC (p-value between 0.012-0.002). The relative volume proportion of SMC was 57.8%, their numerical density was 425 925 mm-3, surface density of SMC was 405.9 mm-1 and the mean cell volume of 203 SMC was 1 358 microns3. Delaunay triangulation of centres of gravity did not reveal any anisotropy in arrangement of SMC. The mean distance of profiles of neighbouring cells was 26.2 µm, providing that the cells were situated in vertices of a model network formed by equilateral triangles. Stanovili jsme Youngův modul živých (34 kPa) a fixovaných (440 kPa) tkáňových vzorků. Mez pevnosti byla 0.10 MPa u živých a 0.46 MPa u fixovaných vzorků. Trhliny probíhaly preferenčně kolagenním vazivem. Objemová frakce svaloviny činila 57.8%, numerická hustota buněk byla 425 925 mm-3, povrchová hustota byla 405.9 mm-1 a stření objem buněk byl 1 358 µm3. Delaunayova triangulace neprokázala anizotropii svalových buněk, jejichž střední vzdálenost činila 26.2 µm. We identified the elasticity modulus for both living (34 kPa) and formalin-fixed samples (440 kPa). The ultimate strength was 0.10 MPa in living samples and (0.46 MPa) in formalin-fixed samples. The microcracks ran preferentially through the collagen connective tissue far from the SMC rather than through the connective tissue surrounding the SMC (p-value between 0.012-0.002). The relative volume proportion of SMC was 57.8%, their numerical density was 425 925 mm-3, surface density of SMC was 405.9 mm-1 and the mean cell volume of 203 SMC was 1 358 microns3. Delaunay triangulation of centres of gravity did not reveal any anisotropy in arrangement of SMC. The mean distance of profiles of neighbouring cells was 26.2 µm, providing that the cells were situated in vertices of a model network formed by equilateral triangles.
dcterms:title
Stereological assessment, mechanical measurement and computer modelling of smooth muscle Stereologické hodnocení, mechanické měření a počítačové modelování hladkého svalu Stereological assessment, mechanical measurement and computer modelling of smooth muscle
skos:prefLabel
Stereological assessment, mechanical measurement and computer modelling of smooth muscle Stereological assessment, mechanical measurement and computer modelling of smooth muscle Stereologické hodnocení, mechanické měření a počítačové modelování hladkého svalu
skos:notation
RIV/49777513:23520/07:00000157!RIV08-MSM-23520___
n3:strany
101-101
n3:aktivita
n15:Z n15:P
n3:aktivity
P(GA106/05/0219), Z(MSM4977751303)
n3:dodaniDat
n8:2008
n3:domaciTvurceVysledku
n4:9901752 n4:8036519 n4:4948289
n3:druhVysledku
n22:D
n3:duvernostUdaju
n14:S
n3:entitaPredkladatele
n19:predkladatel
n3:idSjednocenehoVysledku
452487
n3:idVysledku
RIV/49777513:23520/07:00000157
n3:jazykVysledku
n20:eng
n3:klicovaSlova
Microscopy; stereology; biomechanics; smooth muscle
n3:klicoveSlovo
n11:biomechanics n11:smooth%20muscle n11:Microscopy n11:stereology
n3:kontrolniKodProRIV
[BF081A8EBC63]
n3:mistoKonaniAkce
Brno
n3:mistoVydani
Brno
n3:nazevZdroje
5th International Conference on Materials Structure & Micromechanics of Fracture
n3:obor
n17:BO
n3:pocetDomacichTvurcuVysledku
3
n3:pocetTvurcuVysledku
3
n3:projekt
n9:GA106%2F05%2F0219
n3:rokUplatneniVysledku
n8:2007
n3:tvurceVysledku
Holeček, Miroslav Tonar, Zbyněk Kochová, Petra
n3:typAkce
n21:WRD
n3:zahajeniAkce
2007-01-01+01:00
n3:zamer
n6:MSM4977751303
s:numberOfPages
1
n7:hasPublisher
Vysoké učení technické v Brně. Nakladatelství VUTIUM
n18:isbn
978-80-214-3434-9
n5:organizacniJednotka
23520