This HTML5 document contains 44 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n17http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n11http://purl.org/net/nknouf/ns/bibtex#
n6http://localhost/temp/predkladatel/
n7http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n18http://linked.opendata.cz/ontology/domain/vavai/
n10https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n8http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F49777513%3A23220%2F14%3A43924098%21RIV15-MSM-23220___/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n14http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n20http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n16http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F49777513%3A23220%2F14%3A43924098%21RIV15-MSM-23220___
rdf:type
n18:Vysledek skos:Concept
dcterms:description
This paper deals with the calculation of dangerous inductive effects of overhead very high voltage lines on close steel pipelines, with a focus on refining the input data precision. The problem of evaluating mutual electromagnetic influence very high voltage overhead lines and nearby pipeline systems has high importance not only for the lifetime and operating conditions of both devices, but especially for safety. This paper is about special aspects of this problem. Attention will be paid to a substantial element needed to calculate longitudinal voltage, which is the complete reduction factor, which represents the degree of influence limitation of magnetic field on the affected in earth stored facilities and is dependent not just only on the overhead earth wire and close railway yards, but also on all other parallel in earth deposited metal structures. Commonly used pipeline protection from the effects of the inductive of HV overhead lines is installing parallel of grounding FeZn strap to the protected pipeline. The paper will introduce options for optimal installation position. This paper deals with the calculation of dangerous inductive effects of overhead very high voltage lines on close steel pipelines, with a focus on refining the input data precision. The problem of evaluating mutual electromagnetic influence very high voltage overhead lines and nearby pipeline systems has high importance not only for the lifetime and operating conditions of both devices, but especially for safety. This paper is about special aspects of this problem. Attention will be paid to a substantial element needed to calculate longitudinal voltage, which is the complete reduction factor, which represents the degree of influence limitation of magnetic field on the affected in earth stored facilities and is dependent not just only on the overhead earth wire and close railway yards, but also on all other parallel in earth deposited metal structures. Commonly used pipeline protection from the effects of the inductive of HV overhead lines is installing parallel of grounding FeZn strap to the protected pipeline. The paper will introduce options for optimal installation position.
dcterms:title
Analysis of the inductive effects of overhead lines to close pipelines Analysis of the inductive effects of overhead lines to close pipelines
skos:prefLabel
Analysis of the inductive effects of overhead lines to close pipelines Analysis of the inductive effects of overhead lines to close pipelines
skos:notation
RIV/49777513:23220/14:43924098!RIV15-MSM-23220___
n3:aktivita
n9:S
n3:aktivity
S
n3:dodaniDat
n16:2015
n3:domaciTvurceVysledku
n7:6473830 n7:1351346
n3:druhVysledku
n15:D
n3:duvernostUdaju
n19:S
n3:entitaPredkladatele
n8:predkladatel
n3:idSjednocenehoVysledku
2821
n3:idVysledku
RIV/49777513:23220/14:43924098
n3:jazykVysledku
n14:eng
n3:klicovaSlova
influence of parallel lines; one phase short circuit; induced voltage; overhead line; limiting wire; pipeline; inductive influence
n3:klicoveSlovo
n4:influence%20of%20parallel%20lines n4:inductive%20influence n4:overhead%20line n4:induced%20voltage n4:one%20phase%20short%20circuit n4:limiting%20wire n4:pipeline
n3:kontrolniKodProRIV
[CB5551B62AA4]
n3:mistoKonaniAkce
Hotel Santon,Brno
n3:mistoVydani
Brno
n3:nazevZdroje
Proceedings of the 2014 15th International Scientific Conference on Electric Power Engineering
n3:obor
n20:JE
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
2
n3:rokUplatneniVysledku
n16:2014
n3:tvurceVysledku
Noháč, Karel Janda, Zbyněk
n3:typAkce
n17:WRD
n3:zahajeniAkce
2014-05-12+02:00
s:numberOfPages
6
n11:hasPublisher
Vysoké učení technické v Brně
n10:isbn
978-1-4799-3806-3
n6:organizacniJednotka
23220