This HTML5 document contains 49 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n10http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n18http://purl.org/net/nknouf/ns/bibtex#
n7http://localhost/temp/predkladatel/
n4http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n20http://linked.opendata.cz/ontology/domain/vavai/
n6https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n17http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F49777513%3A23220%2F14%3A43922290%21RIV15-MSM-23220___/
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n11http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n19http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n13http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F49777513%3A23220%2F14%3A43922290%21RIV15-MSM-23220___
rdf:type
skos:Concept n20:Vysledek
dcterms:description
This paper deals with practicable modelling of single-circuit power lines with covered conductors. Moreover, it focuses on the modelling of medium voltage overhead lines with covered conductors for double-circuit distribution. Despite of not being currently the one of prominent simulation tools in the field of electric power engineering, software package DYNAST was chosen for all the modelling procedures. For performing the simulations of any realistic operation/failure state on the medium voltage level in electrical networks, the use of advanced power line models is essential. Some simulation programs, e.g. DYNAST, contain no models of medium voltage power lines with covered conductors in their libraries. Therefore, the development of such robust models must be properly done first. For these models, it is also important to consider more accurate methods for the calculation of passive parameters, which correspond to the behaviour of a real power line. This paper deals with practicable modelling of single-circuit power lines with covered conductors. Moreover, it focuses on the modelling of medium voltage overhead lines with covered conductors for double-circuit distribution. Despite of not being currently the one of prominent simulation tools in the field of electric power engineering, software package DYNAST was chosen for all the modelling procedures. For performing the simulations of any realistic operation/failure state on the medium voltage level in electrical networks, the use of advanced power line models is essential. Some simulation programs, e.g. DYNAST, contain no models of medium voltage power lines with covered conductors in their libraries. Therefore, the development of such robust models must be properly done first. For these models, it is also important to consider more accurate methods for the calculation of passive parameters, which correspond to the behaviour of a real power line.
dcterms:title
Modelling of Power Lines with Covered Conductors in Simulation Software DYNAST Modelling of Power Lines with Covered Conductors in Simulation Software DYNAST
skos:prefLabel
Modelling of Power Lines with Covered Conductors in Simulation Software DYNAST Modelling of Power Lines with Covered Conductors in Simulation Software DYNAST
skos:notation
RIV/49777513:23220/14:43922290!RIV15-MSM-23220___
n3:aktivita
n19:S
n3:aktivity
S
n3:dodaniDat
n13:2015
n3:domaciTvurceVysledku
n4:1351346 n4:7125704 n4:7512325
n3:druhVysledku
n9:D
n3:duvernostUdaju
n16:S
n3:entitaPredkladatele
n17:predkladatel
n3:idSjednocenehoVysledku
29911
n3:idVysledku
RIV/49777513:23220/14:43922290
n3:jazykVysledku
n8:eng
n3:klicovaSlova
simulation software DYNAST; modified reflection method; reflection method; working capacitance; phase-to-phase capacitance; capacitance to earth; potential coefficients; bare conductors; covered conductors; covered medium voltage power line
n3:klicoveSlovo
n11:capacitance%20to%20earth n11:covered%20conductors n11:covered%20medium%20voltage%20power%20line n11:modified%20reflection%20method n11:reflection%20method n11:working%20capacitance n11:bare%20conductors n11:potential%20coefficients n11:simulation%20software%20DYNAST n11:phase-to-phase%20capacitance
n3:kontrolniKodProRIV
[FED51A995429]
n3:mistoKonaniAkce
Hotel SANTON Brno, Czech Republic
n3:mistoVydani
Brno
n3:nazevZdroje
Proccedings of the 2014 15th International Scientific Conference on Electric Power Engineering (EPE)
n3:obor
n12:JE
n3:pocetDomacichTvurcuVysledku
3
n3:pocetTvurcuVysledku
3
n3:rokUplatneniVysledku
n13:2014
n3:tvurceVysledku
Veleba, Jan Noháč, Karel Síťař, Vladislav
n3:typAkce
n10:WRD
n3:zahajeniAkce
2014-05-12+02:00
s:numberOfPages
6
n18:hasPublisher
Brno University of Technology, Faculty of Electrical Engineering and Communication
n6:isbn
978-1-4799-3806-3
n7:organizacniJednotka
23220