This HTML5 document contains 42 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n13http://localhost/temp/predkladatel/
n12http://purl.org/net/nknouf/ns/bibtex#
n17http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n8http://linked.opendata.cz/resource/domain/vavai/subjekt/
n7http://linked.opendata.cz/ontology/domain/vavai/
n19https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n18http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F49777513%3A23220%2F12%3A43916366%21RIV13-MSM-23220___/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n9http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n20http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n15http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n14http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F49777513%3A23220%2F12%3A43916366%21RIV13-MSM-23220___
rdf:type
n7:Vysledek skos:Concept
dcterms:description
The changes in the supply network configuration can significantly influence the voltage at individual sites during fault events. The main mitigation method against interruptions is the installation of redundant components (loop system, multiple sources). But the redundant components can worsen conditions during voltage dip events mainly caused remote faults. The paper deals with an impact of the network configuration on the voltage dip magnitude, especially with the impact of a network operated in a radial way, a network with loop lines or parallel lines, and the impact of a spot network or an on-site (local) generator. The changes in the supply network configuration can significantly influence the voltage at individual sites during fault events. The main mitigation method against interruptions is the installation of redundant components (loop system, multiple sources). But the redundant components can worsen conditions during voltage dip events mainly caused remote faults. The paper deals with an impact of the network configuration on the voltage dip magnitude, especially with the impact of a network operated in a radial way, a network with loop lines or parallel lines, and the impact of a spot network or an on-site (local) generator.
dcterms:title
Impact of Changes in Supply Network Configuration on During-Fault Voltage in Distribution System Impact of Changes in Supply Network Configuration on During-Fault Voltage in Distribution System
skos:prefLabel
Impact of Changes in Supply Network Configuration on During-Fault Voltage in Distribution System Impact of Changes in Supply Network Configuration on During-Fault Voltage in Distribution System
skos:notation
RIV/49777513:23220/12:43916366!RIV13-MSM-23220___
n7:predkladatel
n8:orjk%3A23220
n4:aktivita
n15:S
n4:aktivity
S
n4:dodaniDat
n14:2013
n4:domaciTvurceVysledku
n17:7305087
n4:druhVysledku
n10:C
n4:duvernostUdaju
n20:S
n4:entitaPredkladatele
n18:predkladatel
n4:idSjednocenehoVysledku
140582
n4:idVysledku
RIV/49777513:23220/12:43916366
n4:jazykVysledku
n6:eng
n4:klicovaSlova
local generator; power line; network configuration; short-circuit; voltage dip; power quality; distribution system
n4:klicoveSlovo
n9:local%20generator n9:power%20line n9:voltage%20dip n9:short-circuit n9:power%20quality n9:network%20configuration n9:distribution%20system
n4:kontrolniKodProRIV
[C8819DD33278]
n4:mistoVydani
Praha
n4:nazevEdiceCisloSvazku
Neuveden
n4:nazevZdroje
Electric Power Engineering and Ecology - Selected Parts V.
n4:obor
n5:JE
n4:pocetDomacichTvurcuVysledku
1
n4:pocetStranKnihy
100
n4:pocetTvurcuVysledku
1
n4:rokUplatneniVysledku
n14:2012
n4:tvurceVysledku
Tesařová, Miloslava
s:numberOfPages
7
n12:hasPublisher
BEN - technická literatura
n19:isbn
978-80-7300-462-0
n13:organizacniJednotka
23220